MPD MPE-150S-05

MPE-150S Series
Si l O
Single
Output, 150W
0
Compact, Enclosed
AC/DC Power Supplies
Electrical Specifications
Key Features:
• 150W Output Power
• Selectable 88-264 AC Input
• EN 60950 Compliant
• Eight Single Output Models
• Meets EN55022
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
• >285 kHour MTBF
Inrush Current
• Compact Metal Enclosure
Safety Ground Leakage Current
Conditions
Min.
Typ.
88
115
176
220
248
47
See Model Selection Guide
Cold Start, 115 VAC
17.0
Cold Start, 230 VAC
35.0
115 VAC
230 VAC
Max.
132
264
370
63
1.5
3.5
mA
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
115 VAC
20
230 VAC
28
230 VAC
100
230 VAC
50
±0.02
Continuous (Autorecovery)
See Note 3 115
See Note 4 110
Max.
Units
Switch Selectable
Units
VAC
VDC
Hz
A Pk
Output
RoHS Compliant
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
Set-Up Time
Rise Time
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
mSec
mSec
mSec
%/°C
135
160
General
Parameter
Isolation Voltage
Isolation resistance
EMI/RFI
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
EMC Compliance
Conditions
Input to Output
Input to Ground
Output to Ground
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Switching Frequency
Min.
3,000
1,500
500
Typ.
Max.
Units
VAC
100
MΩ
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
25
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
Max.
-10
+25
+60
-20
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
Physical
Case Size
Case Material
Weight
7.83 x 4.33 x 1.97 Inches (199.0 x 110.0 x 50.0 mm)
Vented Metal Enclosure
28.3 Oz (0.8 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
285
kHours
IEN 60950, IEC 60950
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Model Selection Guide
Input
Current (A)
Model
Number
115 VAC
230 VAC
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
MPE-150S-05
MPE-150S-09
MPE-150S-12
MPE-150S-13.5
MPE-150S-15
MPE-150S-24
MPE-150S-27
MPE-150S-48
Output
Voltage (VDC)
Rated
5.0
9.0
12.0
13.5
15.0
24.0
27.0
48.0
Notes:
1. Output voltage tolerance includes the the effects of
set point accuracy, line regulation and load regulation.
2. Ripple and noise is measured at 20 MHz bandwidth
using a 12 inch twisted pair wire to connect to the
power supply terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close to the power
supply terminals as possible.
3. The overvoltage protection circuit shuts down the
output. The unit must be repowered to recover once
the fault condition is removed.
4. The overload protection circuit shuts down the output. The unit must be repowered to recover once the
fault condition is removed.
5. Efficiency is measured with a 115 VAC input.
6. It is recommended that a fuse be used on the input
of a power supply for protection. For the MPE-150S
series, a 7.5A/250 VAC slow blow should be used.
Adjust
Current (A)
Rated
4.5 - 5.5
8.0 - 10.4
10.6 - 13.2
12.0 - 15.0
13.5 - 16.5
21.0 - 28.0
24.0 - 30.0
43.0 - 53.0
30.0
16.7
12.5
11.2
10.0
6.5
5.6
3.2
Range
Output
Tolerance
(%)
0 to 30.0
0 to 16.7
0 to 12.5
0 to 11.2
0 to 10.0
0 to 6.5
0 to 5.6
0 to 3.2
Ripple &
Noise
Efficiency
(%, Typ)
(mV p-p)
±2.0
±1.0
±1.0
±1.0
±1.0
±1.0
±1.0
±1.0
150
180
180
180
180
240
240
240
78
80
82
83
84
85
86
87
Mechanical Dimensions
Pin Connections
Pin
Function
1
2
3
4
5
6
7
AC-Line
AC-Neutral
AC-Ground
-Vout
-Vout
+Vout
+Vout
Derating Curve
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Static Characteristics (24 Vout)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]