SENSORTECHNICS AWM92100V

AWM90000 Series
Mass flow sensor for gases
FEATURES
· Ranges 0...±200 sccm1
or 0...±2 "H2O (0...±5 mbar)
· Bidirectional sensing
· Actual mass flow sensing
· Low differential pressure sensing
SERVICE
To be used with dry gases only
The AWM series is NOT designed for liquid
flow and will be damaged by liquid flow through
the sensor
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage2
8 to 15 V
typ. 10 ±0.01 V
Power consumption
50 mW
Temperature limits
Operating
Storage
-25 to 85°C
-40 to 90°C
Mechanical shock
100 g (5 drops, 6 axes)
1
2
3
4
5
6
7
8
Note:
1
sccm denotes standard cubic centimeters per minute
2
Output voltage is ratiometric to supply voltage
December 2007 / 592
1/6
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
FLOW SENSOR CHARACTERISTICS3
VS = 10 ±0.01 V, TA = 25°C
Part no.
Flow range
(full scale)
AWM92100V
±200 sccm
Pressure
range
±2 "H2O
AWM92200V
Output voltage
@ trim point
Max. flow change4
5.0 l/sec
77 mV @ 200 sccm
5.0 l/sec
38 mV @ 2 "H2O
PERFORMANCE CHARACTERISTICS
VS = 10 ±0.01 V, TA = 25°C
Characteristics
Zero offset
Repeatability and hysteresis (combined)
Min.
Typ.
Max.
Unit
-15
0
15
mV
±0.35
%FSO
AWM92100V
AWM92200V
±0.1
Ratiometricity error2
Temperature effects5
Offset
Span
-25 to 85 °C6
-25 to 25 °C
25 to 85 °C
±2.07
-3.0
AWM92200V
25
5
AWM92100V
±1.08
Sensor resistance (pin 1 - pin 2, pin 1 - pin 8)
-30
1.5
%FSO
% reading
%FSO
5
1.75
Sensor current
Common mode pressure
mV
8
AWM92100V
AWM92200V
Response time
% reading
±0.30
1.0
% reading
2.2
kOhm
0.6
mA
3.0
ms
25
p si
Notes:
2
Output voltage is ratiometric to supply voltage
3
A 5 micron filter is recommended for all devices.
4
Maximum allowable rate of flow change to prevent damage.
5
Temperature shifts in differential pressure devices are mostly due to the density change of the gas over temperature.
6
Shift is relative to 25 °C.
7
Assumes low TCR bridge resistance used (pins 2 and 8).
8
Requires recommended Rc value of 1K Ohm is used (pins 3 to 7) and typ. heater control circuit. Maximum current Rh.
2/6
December 2007 / 592
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
OUTPUT FLOW VS INTERCHANGEABILITY
VS = 10 ±0.01 V, TA = 25°C
OUTPUT CURVES
December 2007 / 592
3/6
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
HEATER CONTROL CIRCUIT
SENSING BRIDGE SUPPLY CIRCUIT
6
A)
10 V
Ra
Rb
24.9 kOhm
5
7
1 kOhm
Rh
3
B)
2
24.9 kOhm
8
Rr
4
1
Note:
Circuits required for operation per specifications. Circuits are not on board the sensor.
A) Customer supplied 1 kOhm resistor (affects temperature compensation and span voltage).
B) Customer supplied 24.9 kOhm matched bridge resistors (affects null output voltage).
Output is measured differentially from pins 8 to 2.
HEATER CONTROL CIRCUIT
(suggested)
DIFFERENTIAL INSTRUMENTATION
AMPLIFIER CIRCUIT (OPTIONAL)
 2 R + R1  R4 
 (V2 − V1 ) + VOffset
VO =  2
 R1  R3 
 R6 

where VOffset = VS 
 R6 + R5 
4/6
December 2007 / 592
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
OUTLINE DRAWING
13.08
(0.515)
8x3.05
(0.12)
8x0.25
(8x0.01)
7x2.54
(0.10)
8x0.51
(0.02)
15.75
(0.62)
17.02
(0.67)
12.57
(0.50)
1.02
(0.04)
27.94
(1.10)
1.14
(0.05)
32.39
(1.28)
2x Ø 1.17
(2x Ø 0.05)
2.79
(0.11)
13.21
(0.52)
2x Ø 4.70
(2x Ø0.19)
10.41
(0.41)
mass: approx. 5.6 g
December 2007 / 592
Ø 3.81
(Ø 0.15)
19.3
(0.76)
30.48
(1.20)
dimensions in mm (inches)
5/6
www.sensortechnics.com
AWM90000 Series
Mass flow sensor for gases
GAS CORRECTION FACTORS9
Gas type
Helium (He)
Hydrogen (H2)
Argon (Ar)
Nitrogen (N2)
Oxygen (O2)
Ai r
Nitric oxide (NO)
Carbon monoxide (CO)
Methane (CH4)
Ammonia (NH3)
Nitrous oxide (N2O)
Nitrogen dioxide (NO2)
Carbon dioxide (CO2)
Correction factor (approx.)
0.510
0.710,11
0.95
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.35
1.35
1.35
Notes:
9
Gas correction factors are referenced to nitrogen (N2) as calibration gas type. Approximate gas correction factors are provided
as guidelines only. Individual gas types may perform differently at temperature extremes and varying flow rates.
10
When sensing Hydrogen (H2) or Helium (He) it may be necessary to power the mass flow sensor using increased supply voltage:
Hydrogen typ. 12 V, Helium typ. 15 V
11
Hydrogen (H2) flow measurement requires the use of a special sensor. These devices provide normal operation when sensing
hydrogen flow and are designated with an "H" at the end of the order number.
ORDERING INFORMATION
Flow range
Dry gas
±200 sccm
AWM92100V
Pressure range
Dry gas
±2 "H2O (±5 mbar)
AWM92200V
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
6/6
December 2007 / 592