SCAS233 − AUGUST 1992 − REVISED APRIL 1993 • DW PACKAGE (TOP VIEW) Suitable for Use in Applications Such as: − Differential Line Drivers − Complementary Input Circuits for Decoders and Code Converters Flow-Through Architecture Optimizes PCB Layout Center-Pin VCC and GND Pin Configurations Minimize High-Speed Switching Noise EPIC (Enhanced-Performance Implanted CMOS) 1-µm Process 500-mA Typical Latch-Up Immunity at 125°C • • • • 1A 1Y 1Z 2Y GND GND GND GND 2Z 3Y 3Z 3D description The 74AC11800 is a triple 4-input AND/NAND gate. Elimination of decode spikes in symmetrical decoder and code-converter applications makes the device useful for applications such as a decoder or differential line driver. 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 1B 1C 1D 2A 2B VCC VCC 2C 2D 3A 3B 3C The 74AC11800 is characterized for operation from −40°C to 85°C. FUNCTION TABLE INPUTS B C D 1B 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D Z L X X X L H L X X L H X X L X L H X X X L L H H H H H H L logic diagram, each section (positive logic) 1 24 Y X logic symbol† 1A OUTPUTS A 2 & 23 3 22 21 4 20 17 9 16 15 10 14 13 11 12 1Y A B C D 1Z Z Y 2Y 2Z 3Y 3Z † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. EPIC is a trademark of Texas Instruments Incorporated. Copyright 1993, Texas Instruments Incorporated ! "#$ ! %#&'" ($) (#"! " !%$""! %$ *$ $! $+! !#$! !(( ,-) (#" %"$!!. ($! $"$!!'- "'#($ $!. '' %$$!) • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • 2−1 SCAS233 − AUGUST 1992 − REVISED APRIL 1993 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡ Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±150 mA Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C ‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed. recommended operating conditions (see Note 2) VCC Supply voltage VIH High-level input voltage VCC = 3 V VCC = 4.5 V VCC = 5.5 V VCC = 3 V VIL MIN NOM MAX 3 5 5.5 0.9 1.35 0 Output voltage 0 IOH High-level output current ∆t /∆v VCC = 3 V VCC = 4.5 V 2−2 VCC = 4.5 V VCC = 5.5 V 24 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 V V −4 −24 −24 Input transition rise or fall rate • VCC VCC VCC = 5.5 V VCC = 3 V TA Operating free-air temperature NOTE 2: Unused or floating inputs must be held high or low. V 1.65 Input voltage Low-level output current V 3.85 VI VO IOL V 2.1 3.15 VCC = 4.5 V VCC = 5.5 V Low-level input voltage UNIT mA 12 mA 24 0 10 ns/ V −40 85 °C SCAS233 − AUGUST 1992 − REVISED APRIL 1993 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS IOH = − 50 µA IOH = − 4 mA VOH TA = 25°C TYP MAX MIN 3V 2.9 2.9 4.5 V 4.4 4.4 5.5 V 5.4 5.4 3V 2.58 2.48 3.94 3.8 IOL = − 24 mA 5.5 V 4.94 4.8 IOH = − 75 mA† 5.5 V IOL = 12 mA IOL = 24 mA IOL = 75 mA† VI = VCC or GND II ICC MIN 4.5 V IOL = 50 µA VOL VCC IO = 0 UNIT V 3.85 3V 0.1 0.1 4.5 V 0.1 0.1 5.5 V 0.1 0.1 3V 0.36 0.44 4.5 V 0.36 0.44 5.5 V 0.36 0.44 5.5 V VI = VCC or GND, VI = VCC or GND MAX V 1.65 5.5 V ± 0.1 ±1 µA 5.5 V 4 40 µA Ci 5V 4 † Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. pF switching characteristics over recommended operating free-air temperature range, VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A, B, C, or D Y or Z MIN TA = 25°C TYP MAX MIN MAX 2.5 5.8 9.8 2.5 10.7 2.7 6.2 10.9 2.7 12 UNIT ns switching characteristics over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A, B, C, or D Y or Z MIN TA = 25°C TYP MAX MIN MAX 2.2 4.6 7.2 2.2 7.7 2.3 4.8 7.7 2.3 8.4 UNIT ns operating characteristics, VCC = 5 V, TA = 25°C PARAMETER Cpd TEST CONDITIONS Power dissipation capacitance per gate CL = 50 pF, • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • f = 1 MHz TYP UNIT 63 pF 2−3 SCAS233 − AUGUST 1992 − REVISED APRIL 1993 PARAMETER MEASUREMENT INFORMATION Input (see Note B) From Output Under Test CL = 50 pF (see Note A) VCC 50% VCC 50% VCC 0V tPLH tPHL 500 Ω 50% VCC Output VOH 50% VCC VOL VOLTAGE WAVEFORMS LOAD CIRCUIT NOTES: A. CL includes probe and jig capacitance. B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns. C. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms 2−4 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77001 • IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DLP® Products DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com www.dlp.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2009, Texas Instruments Incorporated