ARTESYN NLP150H-9610

NLP150H SERIES
Single, dual, triple and quad output
•
•
•
•
•
•
•
•
The NLP150H series is a 150W universal input AC/DC power supply in a 6.5 x 3.0 x
3.06 inch package for use in 2U applications. The series has the smallest standard
125 to 150W footprint in the industry, has input harmonic current emission correction
as standard and has 3.3V models to support the semiconductor industry's transition
from 5V to lower operating voltages. The NLP150H provides 150W of output power
with 150LFM of air. Standard features include overvoltage and short circuit protection.
The series has an enclosure with fan option that does not change the overall package
size. The series, with full international safety approval and the CE mark, meets
conducted emissions EN55022 level B and complies to EN61000-4-2,-3,-4, -5 and -6
immunity standards. The NLP150H series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, file servers,
graphic workstations, storage peripherals and PABX's.
Patent No. 5600546 and 5652700
[ 2 YEAR WARRANTY ]
SPECIFICATION
6.5 x 3.0 x 3.06 package (2U applications)
Smallest industry footprint
EN61000-3-2 compliant
Overvoltage and short circuit protection
150W with 150LFM
EN55022, EN55011 conducted emissions level B
EN61000-4-2, -3, -4, -5, -6 immunity compliant
UL, VDE and CSA safety approvals
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Total regulation
(Line and load)
GENERAL SPECIFICATIONS
Single outputs
Multiple outputs (5V, 3.3V)
Auxiliary outputs
Rise time
At turn-on
Transient response
Main output
25% step
at 0.1A/µs
±2.0%
±2.0%
±5.0%
250ms, max.
5.0% or 250mV
max. dev., 1ms max.
recovery to 1%
Temperature coefficient
±0.02%/°C
Overvoltage protection
Single outputs and 125% of nominal
multi outputs 1 and 2 ±10% tolerance
Short circuit protection
Outputs 1 and 2
Universal input
72% typical
Isolation voltage
Input/output
Input/chassis
Switching frequency
Fixed
Approvals and
standards
(See Note 6)
3000VAC
1500VAC
100kHz, ±10kHz
VDE0805, EN60950
IEC950, UL1950
CSA C22.2 No. 950
Weight
Open-frame
With cover and fan
Size
Open-frame
6.5 x 3.0 x 3.06 in.
With cover and fan 7.5 x 3.0 x 3.10 in.
0.5V max. drop
MTBF
MIL-HDBK-217F
90 to 264VAC
680g (24 oz)
900g (31.77 oz)
120VAC
230VAC
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
Input current
120VAC
Input fuse
UL, IEC approved
EMC CHARACTERISTICS
> 200,000 hours
Thermal performance
0°C to +50°C ambient,
150W
150LFM forced air
Non-operating
-40°C to +85°C
+50°C to +70°C,
Derate to
150LFM forced air
50% load
Peak (0°C to +50°C, 60s) (See Note 2)
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 4)
5Hz to 500Hz
Shock
per MIL-STD-810E
47Hz to 63Hz
Input surge current
(cold start)
PAGE 58
16ms @ 150W
ENVIRONMENTAL SPECIFICATIONS
Input frequency range
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
Efficiency
Yes, see table
INPUT SPECIFICATIONS
Input voltage range
120VAC, 60Hz
Continuous
Minimum output current
Remote sense
Hold-up time
19A max.
38A max.
0.7mA
1.4mA
2.4A max.
250VAC 6.3A
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4G rms peak
(7)
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
Level B
Level A
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
516.4 Part IV
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
125-150W AC/DC
|
125 to 150 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENT
OUTPUT
RIPPLE
MAX
(1)
PEAK
TOTAL
(3)
(2)
MODEL
REGULATION
NUMBERS
(8,9)
VOLTAGE
MIN
5V
3A
30A
36A
50mV
±2.0%
NLP150H-9605
12V
1.25A
12.5A
15A
120mV
±2.0%
NLP150H-9612
13.8V
1.1A
11A
13A
120mV
±2.0%
NLP150H-9614
24V
0.63A
6.3A
7.5A
240mV
±2.0%
NLP150H-9624
48V
0.32A
3.2A
3.75A
480mV
±2.0%
NLP150H-9617
5V (VA)
1.5A
15A
18A
50mV
±2.0%
NLP150H-9690
3.3V (VB)
1.5A
15A
18A
50mV
±2.0%
5V (VA)
1.5A
15A
18A
50mV
±2.0%
12V (VB)
0.63A
6.3A
7.5A
120mV
±2.0%
–12V (VC)
0A
0.8A
1.0A
120mV
±5.0%
5V (VA)
1.5A
15A
18A
50mV
±2.0%
15V (VB)
0.5A
5A
6A
150mV
±2.0%
–15V (VC)
0A
0.8A
1.0A
150mV
±5.0%
5V (VA)
1.5A
15A
18A
50mV
±2.0%
3.3V (VB)
1.2A
12A
15A
50mV
±2.0%
12V (VC)
0A
1.25A
1.25A
120mV
±5.0%
-12V (VD)
0A
0.8A
1.0A
120mV
±5.0%
5V (VA)
1.5A
15A
18A
50mV
±2.0%
12V (VB)
0.63A
6.3A
7.5A
120mV
±2.0%
24V (VC)
0A
0.8A
1.0A
240mV
±5.0%
-12V (VD)
0A
0.8A
1.0A
120mV
±5.0%
NLP150H-9608
NLP150H-9610
NLP150H-9691
NLP150H-9602
Notes
1
2
150LFM forced air cooling (150W max.).
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation
limits.
3 Figure is peak-to-peak. Output noise measurements are made across a
20MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF
capacitor.
4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G
rms 5Hz to 500Hz.
5 CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
6 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
7 For system EMI compliance, a ground choke may be required before
connecting the ground wire to the chassis.
8 To order the NLP150H with an enclosure, add the suffix 'E' to the model
number e.g. NLP150H-96XXE. See page 61 for details.
9 For single output models, J2 and J3 must be connected in parallel for
proper operation. To maintain specified regulation on enclosed single
output models and on VA and VB of enclosed multiple output models, the
remote sense pins should be used.
10 For optimum reliability no part of the heatsink should exceed 120°C and
no semi-conductor case temperature should exceed 135°C.
DERATING CURVE
Output Power (Watts)
150W
150 LFM FORCED
AIR COOLING
0°C 10°C
20°C
30°C
40°C
50°C
75W
60°C
70°C
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-0108
Licence No. 98724
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
http://www.artesyn.com
PAGE 59
1
125-150W AC/DC
|
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
125 to 150 Watt
AC/DC universal input switch mode power supplies
Open-frame mechanical drawing
6.50
(165.1)
0.35
(8.89)
3.06
(77.72)
6.085
(154.559)
Va sense J12
Power Good J13
3.000
(76.2)
2.300
(58.42)
J1 AC Input
0.59
(14.99)
0.19
(4.826)
J2
Va Power
J1 AC Input
L
J12
J13
J7 Int Fan Power
J6 Vb Sense
1.825
(46.355)
J3
Vb-d Power
3.00
(76.20)
J7
J6
J2
J3
N
G
Pin # 1 Typ. (•)
0.138-32-UNC-2B (10 Places)
(3 Each Side, 4 on Bottom)
1/4" (6.35) Max. Thread Penetration - Typ.
0.35
(8.89)
5.625
(142.875)
1.750
(44.45)
Third Angle Projection
0.94
(23.876)
Input pin assignment (J1)
(Open-frame only)
The input connector is a standard
Leoco 5-pin polarized header type
connector with 0.156 inch spacing
(3940P05V000) or equivalent. The
recommended mating connector
socket is the Leoco 3940 series
(3940S050000) or equivalent. The
pin assignment is summarized
below. Pin numbering is from right
to left facing the connector.
5.500
(139.7)
0.156 (4 Places)
(4.191)
2.275
(57.785)
The output power connectors are two
standard Leoco 6-pin polarized header
type connectors with 0.156 inch spacing
(3940P06V000) or equivalent. The
recommended mating connector sockets
are the Leoco 3940 series (3940S060000)
or equivalents. The pin assignment is
summarized below. Pin numbering is from
right to left facing the connector. For
single output models, J2 and J3 must be
connected in parallel for proper operation.
Signal pin assignment (J6, J12, J13)
Three two-pin Molex 6373 type
connectors (P/N: 22-23-2021) with 0.100
inch spacing or equivalent are used for
remote sensing and power good signal.
The pin assignment is summarized in the
following tables. Pin numbering is from
right to left facing the connector.
PAGE 60
1.775
(45.085)
6.085
(154.559)
INPUT PIN CONNECTIONS
J1
Pin 1
Ground
Pin 2
No Pin
Pin 3
Neutral (AC Low)
Pin 4
No Pin
Pin 5
Line (AC High)
Output pin assignment (J2, J3)
0.45
(11.43)
5.175
(131.445)
0.19
(4.826)
0.37 Ref.
(9.398)
ALL DIMENSIONS IN INCHES (mm)
Tolerances unless otherwise specified
.xx
=
± 0.02
.xxx
=
± 0.010
PIN CONNECTIONS
J2 (ALL MODELS)
Pin 1
VA
Pin 2
VA
Pin 3
VA
Pin 4
Return
Pin 5
Return
Pin 6
Return
PIN CONNECTIONS
J13 (ALL MODELS)
Pin 1
VA Return
Pin 2
Power Good
J3
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
OUTPUT PIN CONNECTIONS
SINGLE (9)
DUAL
TRIPLE
VA
VB
VC
VA
VB
VB
VA
VB
VB
Return
Return
Return
Return
Return
Return
Return
Return
No Pin
PIN CONNECTIONS
J12 (ALL MODELS)
Pin 1
- Sense VA
Pin 2
+ Sense VA
QUAD
VD
VB
VB
Return
Return
VC
PIN CONNECTIONS
J6 (ALL MODELS)
Pin 1
- Sense VB
Pin 2
+ Sense VB
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
125-150W AC/DC
125 to 150 Watt
AC/DC universal input switch mode power supplies
Enclosed mechanical drawing
0.50
(12.70)
IEC - 380
AC INLET
0.691
(17.55)
0.48
(12.19)
7.50
(190.50)
40mm INTERNAL FAN
5.500
(139.70)
0.35
(8.89)
5.175
(131.445)
2.275
2.300 (57.785)
(58.42)
AIR FLOW
0.38
(9.65)
3.10
(78.74)
0.59
(14.99)
1.50
(38.10)
2.80
(71.12)
2.000
(50.8)
2.09
(53.09)
0.138 (3.505)
32-UNC-2B (2 PLACES)
1.775 1.825
(45.09) (46.36)
0.22
(5.59)
6.05
(153.67)
0.138 (3.505)
32-UNC-2B (10 PLACES) (3 EACH
SIDE, 4 ON BOTTOM)
1/4" max. Thread penetration -Typ.
0.94
(23.88)
2.57
(65.28)
0.156 (3.96) (4 PLS)
0.41
(10.41)
5.625
(142.875)
1.750
(44.45)
THIRD ANGLE
PROJECTION
3.00
(76.20)
1
0.63
(16.00)
OUTPUT CABLE ASSEMBLY
P1 MAIN OUTPUT - 6 INCHES LONG
P4-6 SIG OUTPUTS - 8 INCHES LONG
6.50
(165.1)
0.14
(3.56)
ALL DIMENSIONS IN INCHES (mm)
Tolerances unless otherwise specified
.xx
=
± 0.02
.xxx =
± 0.010
OUTPUT PIN CONNECTIONS
SINGLE
DUAL
TRIPLE
Return
Return
Return
Return
Return
Return
Return
Return
Return
VA
VB
VB
VA
VB
VB
VA
VB
VB
VA
VB
VC
Return
Return
No Connect.
Return
Return
Return
Return
Return
Return
Return
Return
Return
VA
VA
VA
VA
VA
VA
VA
VA
VA
P1
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Pin 13
Pin 14
P4 Va Sense
1
Molex mini-fit connector (P/N: 39-01-2145) or equivalent with Molex crimp
terminals (P/N: 39-00-0059) or equivalent. The pin assignment is summarized
below.
P1 OUTPUT POWER CONNECTOR
1
14
1
7
Signal pin assignment (P4, P5, P6)
Three two-pin Molex mini-fit connectors (P/N: 39-01-4031) with 0.165 inch
spacing or equivalent with Molex crimp terminals (P/N: 39-00-0039) or
equivalent. The pin assignment is summarized in the following tables.
Pin numbering is from right to left facing the connector.
P6 Vb Sense
3
1
PIN CONNECTIONS
P5 (ALL MODELS)
8
MATING END OF CONNECTOR
SHOWN
P5 Power Good
3
PIN CONNECTIONS
P4 (ALL MODELS)
Output pin assignment (P1)
QUAD
Return
Return
Return
VB
VB
VB
VD
VC
Return
Return
Return
VA
VA
VA
3
PIN CONNECTIONS
P6 (ALL MODELS)
- Sense VA
Pin 1
VA Return
Pin 1
No Connection
Pin 2
Pin 3
+ Sense VA
No Connection
Pin 2
Pin 3
No Connection
Power Good
Pin 2
Pin 3
- Sense VB
+ Sense VB
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 61
DS_NLP150H_20010226PDF
Pin 1