NLP150H SERIES Single, dual, triple and quad output • • • • • • • • The NLP150H series is a 150W universal input AC/DC power supply in a 6.5 x 3.0 x 3.06 inch package for use in 2U applications. The series has the smallest standard 125 to 150W footprint in the industry, has input harmonic current emission correction as standard and has 3.3V models to support the semiconductor industry's transition from 5V to lower operating voltages. The NLP150H provides 150W of output power with 150LFM of air. Standard features include overvoltage and short circuit protection. The series has an enclosure with fan option that does not change the overall package size. The series, with full international safety approval and the CE mark, meets conducted emissions EN55022 level B and complies to EN61000-4-2,-3,-4, -5 and -6 immunity standards. The NLP150H series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, file servers, graphic workstations, storage peripherals and PABX's. Patent No. 5600546 and 5652700 [ 2 YEAR WARRANTY ] SPECIFICATION 6.5 x 3.0 x 3.06 package (2U applications) Smallest industry footprint EN61000-3-2 compliant Overvoltage and short circuit protection 150W with 150LFM EN55022, EN55011 conducted emissions level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals All specifications are typical at nominal input, full load at 25°C unless otherwise stated OUTPUT SPECIFICATIONS Total regulation (Line and load) GENERAL SPECIFICATIONS Single outputs Multiple outputs (5V, 3.3V) Auxiliary outputs Rise time At turn-on Transient response Main output 25% step at 0.1A/µs ±2.0% ±2.0% ±5.0% 250ms, max. 5.0% or 250mV max. dev., 1ms max. recovery to 1% Temperature coefficient ±0.02%/°C Overvoltage protection Single outputs and 125% of nominal multi outputs 1 and 2 ±10% tolerance Short circuit protection Outputs 1 and 2 Universal input 72% typical Isolation voltage Input/output Input/chassis Switching frequency Fixed Approvals and standards (See Note 6) 3000VAC 1500VAC 100kHz, ±10kHz VDE0805, EN60950 IEC950, UL1950 CSA C22.2 No. 950 Weight Open-frame With cover and fan Size Open-frame 6.5 x 3.0 x 3.06 in. With cover and fan 7.5 x 3.0 x 3.10 in. 0.5V max. drop MTBF MIL-HDBK-217F 90 to 264VAC 680g (24 oz) 900g (31.77 oz) 120VAC 230VAC Safety ground leakage current 120VAC, 60Hz 230VAC, 50Hz Input current 120VAC Input fuse UL, IEC approved EMC CHARACTERISTICS > 200,000 hours Thermal performance 0°C to +50°C ambient, 150W 150LFM forced air Non-operating -40°C to +85°C +50°C to +70°C, Derate to 150LFM forced air 50% load Peak (0°C to +50°C, 60s) (See Note 2) Relative humidity Non-condensing Altitude Operating Non-operating Vibration (See Note 4) 5Hz to 500Hz Shock per MIL-STD-810E 47Hz to 63Hz Input surge current (cold start) PAGE 58 16ms @ 150W ENVIRONMENTAL SPECIFICATIONS Input frequency range Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity Efficiency Yes, see table INPUT SPECIFICATIONS Input voltage range 120VAC, 60Hz Continuous Minimum output current Remote sense Hold-up time 19A max. 38A max. 0.7mA 1.4mA 2.4A max. 250VAC 6.3A 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4G rms peak (7) EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Perf. Perf. Perf. Perf. Perf. Perf. Level B Level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 516.4 Part IV LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 125-150W AC/DC | 125 to 150 Watt AC/DC universal input switch mode power supplies OUTPUT CURRENT OUTPUT RIPPLE MAX (1) PEAK TOTAL (3) (2) MODEL REGULATION NUMBERS (8,9) VOLTAGE MIN 5V 3A 30A 36A 50mV ±2.0% NLP150H-9605 12V 1.25A 12.5A 15A 120mV ±2.0% NLP150H-9612 13.8V 1.1A 11A 13A 120mV ±2.0% NLP150H-9614 24V 0.63A 6.3A 7.5A 240mV ±2.0% NLP150H-9624 48V 0.32A 3.2A 3.75A 480mV ±2.0% NLP150H-9617 5V (VA) 1.5A 15A 18A 50mV ±2.0% NLP150H-9690 3.3V (VB) 1.5A 15A 18A 50mV ±2.0% 5V (VA) 1.5A 15A 18A 50mV ±2.0% 12V (VB) 0.63A 6.3A 7.5A 120mV ±2.0% –12V (VC) 0A 0.8A 1.0A 120mV ±5.0% 5V (VA) 1.5A 15A 18A 50mV ±2.0% 15V (VB) 0.5A 5A 6A 150mV ±2.0% –15V (VC) 0A 0.8A 1.0A 150mV ±5.0% 5V (VA) 1.5A 15A 18A 50mV ±2.0% 3.3V (VB) 1.2A 12A 15A 50mV ±2.0% 12V (VC) 0A 1.25A 1.25A 120mV ±5.0% -12V (VD) 0A 0.8A 1.0A 120mV ±5.0% 5V (VA) 1.5A 15A 18A 50mV ±2.0% 12V (VB) 0.63A 6.3A 7.5A 120mV ±2.0% 24V (VC) 0A 0.8A 1.0A 240mV ±5.0% -12V (VD) 0A 0.8A 1.0A 120mV ±5.0% NLP150H-9608 NLP150H-9610 NLP150H-9691 NLP150H-9602 Notes 1 2 150LFM forced air cooling (150W max.). Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. 3 Figure is peak-to-peak. Output noise measurements are made across a 20MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF capacitor. 4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G rms 5Hz to 500Hz. 5 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 6 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 7 For system EMI compliance, a ground choke may be required before connecting the ground wire to the chassis. 8 To order the NLP150H with an enclosure, add the suffix 'E' to the model number e.g. NLP150H-96XXE. See page 61 for details. 9 For single output models, J2 and J3 must be connected in parallel for proper operation. To maintain specified regulation on enclosed single output models and on VA and VB of enclosed multiple output models, the remote sense pins should be used. 10 For optimum reliability no part of the heatsink should exceed 120°C and no semi-conductor case temperature should exceed 135°C. DERATING CURVE Output Power (Watts) 150W 150 LFM FORCED AIR COOLING 0°C 10°C 20°C 30°C 40°C 50°C 75W 60°C 70°C International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. 10401-3336-0108 Licence No. 98724 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C http://www.artesyn.com PAGE 59 1 125-150W AC/DC | LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 125 to 150 Watt AC/DC universal input switch mode power supplies Open-frame mechanical drawing 6.50 (165.1) 0.35 (8.89) 3.06 (77.72) 6.085 (154.559) Va sense J12 Power Good J13 3.000 (76.2) 2.300 (58.42) J1 AC Input 0.59 (14.99) 0.19 (4.826) J2 Va Power J1 AC Input L J12 J13 J7 Int Fan Power J6 Vb Sense 1.825 (46.355) J3 Vb-d Power 3.00 (76.20) J7 J6 J2 J3 N G Pin # 1 Typ. (•) 0.138-32-UNC-2B (10 Places) (3 Each Side, 4 on Bottom) 1/4" (6.35) Max. Thread Penetration - Typ. 0.35 (8.89) 5.625 (142.875) 1.750 (44.45) Third Angle Projection 0.94 (23.876) Input pin assignment (J1) (Open-frame only) The input connector is a standard Leoco 5-pin polarized header type connector with 0.156 inch spacing (3940P05V000) or equivalent. The recommended mating connector socket is the Leoco 3940 series (3940S050000) or equivalent. The pin assignment is summarized below. Pin numbering is from right to left facing the connector. 5.500 (139.7) 0.156 (4 Places) (4.191) 2.275 (57.785) The output power connectors are two standard Leoco 6-pin polarized header type connectors with 0.156 inch spacing (3940P06V000) or equivalent. The recommended mating connector sockets are the Leoco 3940 series (3940S060000) or equivalents. The pin assignment is summarized below. Pin numbering is from right to left facing the connector. For single output models, J2 and J3 must be connected in parallel for proper operation. Signal pin assignment (J6, J12, J13) Three two-pin Molex 6373 type connectors (P/N: 22-23-2021) with 0.100 inch spacing or equivalent are used for remote sensing and power good signal. The pin assignment is summarized in the following tables. Pin numbering is from right to left facing the connector. PAGE 60 1.775 (45.085) 6.085 (154.559) INPUT PIN CONNECTIONS J1 Pin 1 Ground Pin 2 No Pin Pin 3 Neutral (AC Low) Pin 4 No Pin Pin 5 Line (AC High) Output pin assignment (J2, J3) 0.45 (11.43) 5.175 (131.445) 0.19 (4.826) 0.37 Ref. (9.398) ALL DIMENSIONS IN INCHES (mm) Tolerances unless otherwise specified .xx = ± 0.02 .xxx = ± 0.010 PIN CONNECTIONS J2 (ALL MODELS) Pin 1 VA Pin 2 VA Pin 3 VA Pin 4 Return Pin 5 Return Pin 6 Return PIN CONNECTIONS J13 (ALL MODELS) Pin 1 VA Return Pin 2 Power Good J3 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 OUTPUT PIN CONNECTIONS SINGLE (9) DUAL TRIPLE VA VB VC VA VB VB VA VB VB Return Return Return Return Return Return Return Return No Pin PIN CONNECTIONS J12 (ALL MODELS) Pin 1 - Sense VA Pin 2 + Sense VA QUAD VD VB VB Return Return VC PIN CONNECTIONS J6 (ALL MODELS) Pin 1 - Sense VB Pin 2 + Sense VB LOW TO MEDIUM POWER AC/DC POWER SUPPLIES | 125-150W AC/DC 125 to 150 Watt AC/DC universal input switch mode power supplies Enclosed mechanical drawing 0.50 (12.70) IEC - 380 AC INLET 0.691 (17.55) 0.48 (12.19) 7.50 (190.50) 40mm INTERNAL FAN 5.500 (139.70) 0.35 (8.89) 5.175 (131.445) 2.275 2.300 (57.785) (58.42) AIR FLOW 0.38 (9.65) 3.10 (78.74) 0.59 (14.99) 1.50 (38.10) 2.80 (71.12) 2.000 (50.8) 2.09 (53.09) 0.138 (3.505) 32-UNC-2B (2 PLACES) 1.775 1.825 (45.09) (46.36) 0.22 (5.59) 6.05 (153.67) 0.138 (3.505) 32-UNC-2B (10 PLACES) (3 EACH SIDE, 4 ON BOTTOM) 1/4" max. Thread penetration -Typ. 0.94 (23.88) 2.57 (65.28) 0.156 (3.96) (4 PLS) 0.41 (10.41) 5.625 (142.875) 1.750 (44.45) THIRD ANGLE PROJECTION 3.00 (76.20) 1 0.63 (16.00) OUTPUT CABLE ASSEMBLY P1 MAIN OUTPUT - 6 INCHES LONG P4-6 SIG OUTPUTS - 8 INCHES LONG 6.50 (165.1) 0.14 (3.56) ALL DIMENSIONS IN INCHES (mm) Tolerances unless otherwise specified .xx = ± 0.02 .xxx = ± 0.010 OUTPUT PIN CONNECTIONS SINGLE DUAL TRIPLE Return Return Return Return Return Return Return Return Return VA VB VB VA VB VB VA VB VB VA VB VC Return Return No Connect. Return Return Return Return Return Return Return Return Return VA VA VA VA VA VA VA VA VA P1 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 P4 Va Sense 1 Molex mini-fit connector (P/N: 39-01-2145) or equivalent with Molex crimp terminals (P/N: 39-00-0059) or equivalent. The pin assignment is summarized below. P1 OUTPUT POWER CONNECTOR 1 14 1 7 Signal pin assignment (P4, P5, P6) Three two-pin Molex mini-fit connectors (P/N: 39-01-4031) with 0.165 inch spacing or equivalent with Molex crimp terminals (P/N: 39-00-0039) or equivalent. The pin assignment is summarized in the following tables. Pin numbering is from right to left facing the connector. P6 Vb Sense 3 1 PIN CONNECTIONS P5 (ALL MODELS) 8 MATING END OF CONNECTOR SHOWN P5 Power Good 3 PIN CONNECTIONS P4 (ALL MODELS) Output pin assignment (P1) QUAD Return Return Return VB VB VB VD VC Return Return Return VA VA VA 3 PIN CONNECTIONS P6 (ALL MODELS) - Sense VA Pin 1 VA Return Pin 1 No Connection Pin 2 Pin 3 + Sense VA No Connection Pin 2 Pin 3 No Connection Power Good Pin 2 Pin 3 - Sense VB + Sense VB Data Sheet © Artesyn Technologies® 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. http://www.artesyn.com PAGE 61 DS_NLP150H_20010226PDF Pin 1