C4000RW Datasheet - Micropower Direct

C4000RW Series
Wide 2:1Input 40W
Single, Dual & Triple Output
DC/DC Con
verters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
• 40W Output Power
• 2:1 Input Voltage Range
• 1,600 VDC Isolation
• 12, 24, & 48V Input
• Single, Dual, Triple Output
• Remote ON/OFF
• >550 kHour MTBF
• Industry Standard Pin-Out
Input Voltage Range
Input Filter
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
␲ (Pi) Filter
Typ.
12.0
24.0
48.0
Max.
18.0
36.0
75.0
Units
Conditions
Typ.
±2.0
±0.5
±1.0
±5.0
±1.0
±2.0
±3.0
±5.0
Max.
Units
%
%
VDC
Output
Parameter
Output Voltage Accuracy, See Note 1
Line Regulation, Single, Dual Output
Line Regulation, Triple Output
Load Regulation, Single Output
Load Regulation, Dual Output
Load Regulation, Triple Output
Ripple, See Note 2
Noise, See Note 2
Output Power Protection, See Note 3
Over Voltage Protection, See Note 4
Temperature Coefficient
Output Short Circuit
Min.
For Vin Min to Max
Vout 1
Vout 2 & Vout 3
Iout = 10% to 100%
Iout = 10% to 100%
Iout = 10% to 100%, Vout 1
Iout = 10% to 100%, Vout 2 & Vout 3
Single Output Models
Dual/Triple Output Models
5V Output Models
12V, 15V &24V Output Models
Dual/Triple Output Models
%
%
%
%
±1.0
%
0.2% Vout + 20 mV P - P Max.
100
mV
±1.0
%
0.5% Vout + 50 mV P - P Max.
120
%
112
165
%
±0.02
%/°C
Continuous (Autorecovery)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Conditions
Switching Frequency, See Note 5
60 Seconds
500 VDC
100 kHz, 1V
5V Output Models
12V Output Models
All Other Models
Min.
1,600
1,000
Typ.
Max.
1,000
250
200
400
Units
VDC
M⍀
pF
kHz
Remote On/Off, See Note 6
Parameter
Supply On
Supply Off
Input Current (On)
Input Current (Off)
Control Common
Conditions
Min.
5.0
-1.0
Typ.
Max.
Units
15.0
VDC
+1.0
VDC
-1
mA
1
mA
Referenced to Negative Input (pin 2)
Min.
-25
Typ.
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
-55
See Derating Curve
RH, Non-condensing
Max.
+70
+100
+105
Units
°C
°C
°C
95
%
2.0 x 2.0 x 0.45 Inches (50.8 x 50.8 x 11.4 mm)
Nickel Coated Copper with Non-Conductive Base
2.47 Oz (70g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
550
Typ.
Max.
Units
kHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
-0.7
Typ.
Max.
25.0
50.0
100.0
260
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (0.1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Model
Number
C4001RW
C4002RW
C4003RW
C4004RW
C4005RW
C4006RW
C4007RW
C4008RW
C4009RW
C4011RW
C4012RW
C4013RW
C4014RW
C4015RW
C4016RW
C4017RW
C4018RW
C4019RW
C4021RW
C4022RW
C4023RW
C4024RW
C4025RW
C4026RW
C4027RW
C4028RW
C4029RW
Voltage (VDC)
Nom. Range
12
9 - 18
12
9 - 18
12
9 - 18
12
9 - 18
12
9 - 18
12
9 - 18
12
9 - 18
12
9 - 18
12
9 - 18
24 18 - 36
24 18 - 36
24 18 - 36
24 18 - 36
24 18 - 36
24 18 - 36
24 18 - 36
24 18 - 36
24 18 - 36
48 36 - 75
48 36 - 75
48 36 - 75
48 36 - 75
48 36 - 75
48 36 - 75
48 36 - 75
48 36 - 75
48 36 - 75
Input
Output 1
Current (mA)
Voltage Current
Full-Load No-Load (VDC) (A, Max)
3,922
120
5.0
8.00
3,922
120
12.0
3.33
3,922
120
15.0
2.66
3,922
120
24.0
1.66
3,557
120
+5.0
+3.50
3,922
120
+12.0
+1.66
3,922
120
+15.0
+1.32
3,922
120
5.0
5.00
3,922
120
5.0
5.00
1,915
85
5.0
8.00
1,938
85
12.0
3.33
1,938
85
15.0
2.66
1,938
85
24.0
1.66
1,757
85
+5.0
+3.50
1,938
85
+12.0
+1.66
1,938
85
+15.0
+1.32
1,938
85
5.0
5.00
1,938
85
5.0
5.00
947
50
5.0
8.00
957
50
12.0
3.33
957
50
15.0
2.66
957
50
24.0
1.66
868
50
+5.0
+3.50
957
50
+12.0
+1.66
957
50
+15.0
+1.32
957
50
5.0
5.00
957
50
5.0
5.00
Max.
Fuse
Output Efficiency Capacitive
Rating
Load
Voltage Current Voltage Current Power
(Typ %)
Slow-Blow
(µF Max)
Output 2
(VDC)
Output 3
(A, Max)
(VDC)
(A, Max)
-5.0
-12.00
-15.00
+12.0
+15.0
-3.50
-1.66
-1.32
+0.60
+0.50
-12.0
-15.0
-0.60
-0.50
-5.0
-12.00
-15.00
+12.0
+15.0
-3.50
-1.66
-1.32
+0.60
+0.50
-12.0
-15.0
-0.60
-0.50
-5.0
-12.00
-15.00
+12.0
+15.0
-3.50
-1.66
-1.32
+0.60
+0.50
-12.0
-15.0
-0.60
-0.50
Notes:
1. For triple output models, the voltage accuracy of the auxiliary outputs is ±5%.
2. When measuring output ripple, it is recommended that an external 1.0 µF ceramic in parallel with a 10 µF capacitor be placed
from the +Vout pin to the -Vout pin.
3. The unit will recover automatically when the fault condition is removed.
4. Over voltage protection is provided by a zener diode clamp.
5. Typical switching frequency for 12V input models is 200 kHtz.
6. If the on/off pin (Pin 4) is left open, the unit operates.
7. No load operation will not damage these units, but they may not meet all spec’s.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
(W)
(mA)
40.0
40.0
40.0
40.0
35.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
35.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
40.0
35.0
40.0
40.0
40.0
40.0
85
85
85
85
82
85
85
85
85
87
86
86
86
83
86
86
86
86
88
87
87
87
84
87
87
87
87
13,600
1,800
1,200
330
±1,000
±150
±82
1,000/ ±120
1,000/ ±82
13,600
1,800
1,200
330
±1,000
±150
±82
1,000/ ±120
1,000/ ±82
13,600
1,800
1,200
330
±1,000
±150
±82
1,000/ ±120
1,000/ ±82
8,500
8,500
8,500
8,500
8,500
8,500
8,500
8,500
8,500
4,500
4,500
4,500
4,500
4,500
4,500
4,500
4,500
4,500
2,500
2,500
2,500
2,500
2,500
2,500
2,500
2,500
2,500
Derating Curve
Mechanical Dimensions
External Trim
Pin Connections
Pin
Single
Dual
Triple
1
+Vin
+Vin
+Vin
2
-Vin
-Vin
-Vin
4
On/Off
On/Off
On/Off
5
NC
Vout 1
Vout 2
6
+Vout Common Vout 1
7
-Vout
Vout 2 Common
8
Trim
Trim
Vout 3
NC = No Connection
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
A simple external circuit may be used to adjust
the converter output. To adjust the output DOWN,
connect a 5%, 3W resistor between the plus output
pin and the Vout trim pin. To adjust the output UP,
connect a 5%, 3W resistor between the minus
output pin and the Vout trim pin.
For UP/Down trimming capability, connect a 10 kW
potentiometer between the plus and minus outputs
with the wiper arm connected to the Vout trim pin.
The range for the external trim is about ±10%.
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]