C4000RW Series Wide 2:1Input 40W Single, Dual & Triple Output DC/DC Con verters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Key Features: • 40W Output Power • 2:1 Input Voltage Range • 1,600 VDC Isolation • 12, 24, & 48V Input • Single, Dual, Triple Output • Remote ON/OFF • >550 kHour MTBF • Industry Standard Pin-Out Input Voltage Range Input Filter Conditions Min. 12 VDC Input 9.0 24 VDC Input 18.0 48 VDC Input 36.0 (Pi) Filter Typ. 12.0 24.0 48.0 Max. 18.0 36.0 75.0 Units Conditions Typ. ±2.0 ±0.5 ±1.0 ±5.0 ±1.0 ±2.0 ±3.0 ±5.0 Max. Units % % VDC Output Parameter Output Voltage Accuracy, See Note 1 Line Regulation, Single, Dual Output Line Regulation, Triple Output Load Regulation, Single Output Load Regulation, Dual Output Load Regulation, Triple Output Ripple, See Note 2 Noise, See Note 2 Output Power Protection, See Note 3 Over Voltage Protection, See Note 4 Temperature Coefficient Output Short Circuit Min. For Vin Min to Max Vout 1 Vout 2 & Vout 3 Iout = 10% to 100% Iout = 10% to 100% Iout = 10% to 100%, Vout 1 Iout = 10% to 100%, Vout 2 & Vout 3 Single Output Models Dual/Triple Output Models 5V Output Models 12V, 15V &24V Output Models Dual/Triple Output Models % % % % ±1.0 % 0.2% Vout + 20 mV P - P Max. 100 mV ±1.0 % 0.5% Vout + 50 mV P - P Max. 120 % 112 165 % ±0.02 %/°C Continuous (Autorecovery) General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Conditions Switching Frequency, See Note 5 60 Seconds 500 VDC 100 kHz, 1V 5V Output Models 12V Output Models All Other Models Min. 1,600 1,000 Typ. Max. 1,000 250 200 400 Units VDC M⍀ pF kHz Remote On/Off, See Note 6 Parameter Supply On Supply Off Input Current (On) Input Current (Off) Control Common Conditions Min. 5.0 -1.0 Typ. Max. Units 15.0 VDC +1.0 VDC -1 mA 1 mA Referenced to Negative Input (pin 2) Min. -25 Typ. Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Ambient Case -55 See Derating Curve RH, Non-condensing Max. +70 +100 +105 Units °C °C °C 95 % 2.0 x 2.0 x 0.45 Inches (50.8 x 50.8 x 11.4 mm) Nickel Coated Copper with Non-Conductive Base 2.47 Oz (70g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 550 Typ. Max. Units kHours Conditions 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Min. -0.7 -0.7 -0.7 Typ. Max. 25.0 50.0 100.0 260 Units Absolute Maximum Ratings Parameter Input Voltage Surge (0.1 Sec) Lead Temperature Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C www.micropowerdirect.com Model Selection Guide Model Number C4001RW C4002RW C4003RW C4004RW C4005RW C4006RW C4007RW C4008RW C4009RW C4011RW C4012RW C4013RW C4014RW C4015RW C4016RW C4017RW C4018RW C4019RW C4021RW C4022RW C4023RW C4024RW C4025RW C4026RW C4027RW C4028RW C4029RW Voltage (VDC) Nom. Range 12 9 - 18 12 9 - 18 12 9 - 18 12 9 - 18 12 9 - 18 12 9 - 18 12 9 - 18 12 9 - 18 12 9 - 18 24 18 - 36 24 18 - 36 24 18 - 36 24 18 - 36 24 18 - 36 24 18 - 36 24 18 - 36 24 18 - 36 24 18 - 36 48 36 - 75 48 36 - 75 48 36 - 75 48 36 - 75 48 36 - 75 48 36 - 75 48 36 - 75 48 36 - 75 48 36 - 75 Input Output 1 Current (mA) Voltage Current Full-Load No-Load (VDC) (A, Max) 3,922 120 5.0 8.00 3,922 120 12.0 3.33 3,922 120 15.0 2.66 3,922 120 24.0 1.66 3,557 120 +5.0 +3.50 3,922 120 +12.0 +1.66 3,922 120 +15.0 +1.32 3,922 120 5.0 5.00 3,922 120 5.0 5.00 1,915 85 5.0 8.00 1,938 85 12.0 3.33 1,938 85 15.0 2.66 1,938 85 24.0 1.66 1,757 85 +5.0 +3.50 1,938 85 +12.0 +1.66 1,938 85 +15.0 +1.32 1,938 85 5.0 5.00 1,938 85 5.0 5.00 947 50 5.0 8.00 957 50 12.0 3.33 957 50 15.0 2.66 957 50 24.0 1.66 868 50 +5.0 +3.50 957 50 +12.0 +1.66 957 50 +15.0 +1.32 957 50 5.0 5.00 957 50 5.0 5.00 Max. Fuse Output Efficiency Capacitive Rating Load Voltage Current Voltage Current Power (Typ %) Slow-Blow (µF Max) Output 2 (VDC) Output 3 (A, Max) (VDC) (A, Max) -5.0 -12.00 -15.00 +12.0 +15.0 -3.50 -1.66 -1.32 +0.60 +0.50 -12.0 -15.0 -0.60 -0.50 -5.0 -12.00 -15.00 +12.0 +15.0 -3.50 -1.66 -1.32 +0.60 +0.50 -12.0 -15.0 -0.60 -0.50 -5.0 -12.00 -15.00 +12.0 +15.0 -3.50 -1.66 -1.32 +0.60 +0.50 -12.0 -15.0 -0.60 -0.50 Notes: 1. For triple output models, the voltage accuracy of the auxiliary outputs is ±5%. 2. When measuring output ripple, it is recommended that an external 1.0 µF ceramic in parallel with a 10 µF capacitor be placed from the +Vout pin to the -Vout pin. 3. The unit will recover automatically when the fault condition is removed. 4. Over voltage protection is provided by a zener diode clamp. 5. Typical switching frequency for 12V input models is 200 kHtz. 6. If the on/off pin (Pin 4) is left open, the unit operates. 7. No load operation will not damage these units, but they may not meet all spec’s. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. (W) (mA) 40.0 40.0 40.0 40.0 35.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 35.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 35.0 40.0 40.0 40.0 40.0 85 85 85 85 82 85 85 85 85 87 86 86 86 83 86 86 86 86 88 87 87 87 84 87 87 87 87 13,600 1,800 1,200 330 ±1,000 ±150 ±82 1,000/ ±120 1,000/ ±82 13,600 1,800 1,200 330 ±1,000 ±150 ±82 1,000/ ±120 1,000/ ±82 13,600 1,800 1,200 330 ±1,000 ±150 ±82 1,000/ ±120 1,000/ ±82 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 8,500 4,500 4,500 4,500 4,500 4,500 4,500 4,500 4,500 4,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 2,500 Derating Curve Mechanical Dimensions External Trim Pin Connections Pin Single Dual Triple 1 +Vin +Vin +Vin 2 -Vin -Vin -Vin 4 On/Off On/Off On/Off 5 NC Vout 1 Vout 2 6 +Vout Common Vout 1 7 -Vout Vout 2 Common 8 Trim Trim Vout 3 NC = No Connection Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct A simple external circuit may be used to adjust the converter output. To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and the Vout trim pin. To adjust the output UP, connect a 5%, 3W resistor between the minus output pin and the Vout trim pin. For UP/Down trimming capability, connect a 10 kW potentiometer between the plus and minus outputs with the wiper arm connected to the Vout trim pin. The range for the external trim is about ±10%. We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]