RoboClock CY7B9945V High-speed Multi-phase PLL Clock Buffer Features • • • • • • • • • • • • • • • 500 ps max. Total Timing Budget™ (TTB™) window 24–200 MHz input/output operation Low output-output skew < 200 ps 10 + 1 LVTTL outputs driving 50Ω terminated lines Dedicated feedback output Phase adjustments in 625/1300 ps steps up to +10.4 ns 3.3V LVTTL/LVPECL, fault-tolerant, and hot-insertable reference inputs Multiply/divide ratios of 1–6, 8, 10, and 12 Individual output bank disable Output high-impedance option for testing purposes Integrated phase-locked loop (PLL) with lock indicator Low cycle-cycle jitter (<100 ps peak-peak) 3.3V operation Industrial temperature range: –40°C to +85°C 52-pin 1.4-mm TQFP package Functional Description The CY7B9945V high-speed multi-phase PLL clock buffer offers user-selectable control over system clock functions. Block Diagram FS This multiple-output clock driver provides the system integrator with functions necessary to optimize the timing of high-performance computer and communication systems. The device features a guaranteed maximum TTB window specifying all occurrences of output clocks with respect to the input reference clock across variations in output frequency, supply voltage, operating temperature, input edge rate, and process. Ten configurable outputs each drive terminated transmission lines with impedances as low as 50Ω while delivering minimal and specified output skews at LVTTL levels. The outputs are arranged in two banks of four and six outputs. These banks allow a divide function of 1 to 12, with phase adjustments in 625-ps–1300-ps increments up to ±10.4 ns. The dedicated feedback output allows divide-by functionality from 1 to 12 and limited phase adjustments. However, if needed, any one of the ten outputs can be connected to the feedback input as well as driving other inputs. Selectable reference input is a fault-tolerant feature which allows smooth change over to secondary clock source, when the primary clock source is not in operation. The reference inputs and feedback inputs are configurable to accommodate both LVTTL or Differential (LVPECL) inputs. The completely integrated PLL reduces jitter and simplifies board layout. Pin Configuration 3 REFA+ REFA+ VCCQ FBK GND QF VCCN 1Q1 VCCN 1Q0 REFBREFSEL FBK GND PLL FBDS0 LOCK LOCK REFB+ FBDS1 REFA- 52 51 50 49 48 47 46 45 44 43 42 41 40 3 1F3 3 1Q2 1Q3 DIS1 REFAREFSEL REFBREFB+ 1F2 FS GND 1Q2 VCCN 1Q3 FBF0 1F0 VCCQ DIS2 1F2 MODE 3 GND 3 1DS1 GND 1DS0 1Q1 Divide and Phase Select 2Q5 3 CY7B9945V VCCN 1F1 1Q0 2Q4 3 DIS1 1F0 QF 1F1 3 1F3 FBDS1 VCCQ 3 3 GND FBF0 FBDS0 Divide and Phase Select 1 39 2 38 3 37 4 36 5 35 6 34 7 33 8 32 9 31 10 30 11 29 12 28 13 27 14 15 16 17 18 19 20 21 22 23 24 25 26 1DS0 MODE 2F1 2F0 2DS1 GND 2Q0 VCCN 2Q1 2Q2 VCCN 2Q3 GND 1DS1 2DS0 2Q0 2F0 3 2F1 3 2DS0 3 2DS1 3 2Q1 Divide and Phase Select 2Q2 2Q3 2Q4 2Q5 DIS2 Cypress Semiconductor Corporation Document #: 38-07336 Rev. *D • 3901 North First Street • San Jose, CA 95134 • 408-943-2600 Revised July 24, 2003 RoboClock CY7B9945V Pin Definitions Pin Name I/O Type Description 34 FS Input Three-level Frequency Select. This input must be set according to the nominal frequency Input (fNOM). See Table 1. 40,39, 36,37 REFA+, REFAREFB+, REFB- Input LVTTL/ LVDIFF Reference Inputs. These inputs can operate as differential PECL or single-ended TTL reference inputs to the PLL. When operating as a single-ended LVTTL input, the complementary input must be left open. 38 REFSEL Input LVTTL Reference Select Input. The REFSEL input controls how the reference input is configured. When LOW, it will use the REFA pair as the reference input. When HIGH, it will use the REFB pair as the reference input. This input has an internal pull-down. 42 FBK Input LVTTL Feedback Input Clock. The PLL will operate such that the rising edges of the reference and feedback signals are aligned in phase and frequency. This pin is used to feedback the clock output QF to the phase detector. 28,18, 35,17, 2, 1 1F[0:3], 2F[0:1] Input 19,26 DIS[1:2] Input 14,12, 13,3 [1:2]DS[0:1] Input 3-level Input Output Divider Function Select. Each pair determines the divider ratio of the respective bank of outputs. See Table 4. 29 FBF0 Input 3-level Input Feedback Output Phase Function Select. This input determines the phase of the QF output. See Table 3. 50,51 FBDS[0:1] Input 3-level Input Feedback Output Divider Function Select. This input determines the divider ratio of the QF output. See Table 4. 3-level Input Output Phase Function Select. Each pair determines the phase of the respective bank of outputs. See Table 3. LVTTL Output Disable. Each input controls the state of the respective output bank. When HIGH, the output bank is disabled to “HOLD-OFF” or “High-Z” state; the disable state is determined by MODE. When LOW, outputs 1Q[0:3] and 2Q[0:5] are enabled. See Table 5. 48,46, 1Q[0:3], 2Q[0:5] 32,30, 5,7,8,10 , 20,22 Output LVTTL Clock Outputs with Adjustable Phases and fNOM Divide Ratios. The output frequencies and phases are determined by [1:2]DS[0:1], and 1F[0:3] and 2F[0:1], respectively. See Table 3 and Table 4. 44 QF Output LVTTL Feedback Clock Output. This output is intended to be connected to the FBK input. The output frequency and phase are determined by FBDS[0:1] and FBF0, respectively. See Table 3 and 4. 52 LOCK Output LVTTL PLL Lock Indicator. When HIGH, this output indicates the internal PLL is locked to the reference signal. When LOW, it indicates that the PLL is attempting to acquire lock 25 MODE Input 6,9,21, 31, 45, 47 VCCN PWR Power Supply for the Output Buffers 16,27, 41 VCCQ PWR Power Supply for the Internal Circuitry PWR Device Ground 4,11,15, GND 23,24, 33,43,4 9 Document #: 38-07336 Rev. *D 3-level Input This pin determines the clock outputs’ disable state. When this input is HIGH, the clock outputs will disable to high impedance state (High-Z). When this input is LOW, the clock outputs will disable to HOLD-OFF mode. When in MID, the device will enter factory test mode. Page 2 of 10 RoboClock CY7B9945V Block Diagram Description The PLL adjusts the phase and the frequency of its output signal to minimize the delay between the reference (REFA/B+, REFA/B-) and the feedback (FB) input signals. The CY7B9945V has a flexible REF input scheme. These inputs allow the use of either differential LVPECL or single-ended LVTTL inputs. To configure as single-ended LVTTL inputs, the complementary pin must be left open (internally pulled to 1.5V), then the other input pin can be used as a LVTTL input. The REF inputs are also tolerant to hot insertion. The REF inputs can be changed dynamically. When changing from one reference input to the other reference input of the same frequency, the PLL is optimized to ensure that the clock outputs period will not be less than the calculated system budget (tMIN = tREF (nominal reference period) – tCCJ (cycle-cycle jitter) – tPDEV (max. period deviation)) while reacquiring lock. The FS control pin setting determines the nominal operational frequency range of the divide by one output (fNOM) of the device. fNOM is directly related to the VCO frequency. The FS setting for the device is shown in Table 1. For CY7B9945V, the upper fNOM range extends from 96 MHz to 200 MHz. Table 1. Frequency Range Select fNOM (MHz) FS[1] Min. 24 48 96 LOW MID HIGH Max. 52 100 200 Time Unit Definition Selectable skew is in discrete increments of time unit (tU). The value of a tU is determined by the FS setting and the maximum nominal output frequency. The equation to be used to determine the tU value is as follows: tU = 1/(fNOM*N). N is a multiplication factor which is determined by the FS setting. fNOM is nominal frequency of the device. N is defined in Table 2. Table 2. N Factor Determination FS LOW MID HIGH N 32 16 8 CY7B9945V fNOM (MHz) at which tU = 1.0 ns 31.25 62.5 125 Divide and Phase Select Matrix The Divide Select Matrix is comprised of three independent banks: two banks of clock outputs and one bank for feedback. The Phase Select Matrix, on the other hand, enables independent phase adjustments on 1Q[0:1], 1Q[2:3] and 2Q[0:5]. The frequency of 1Q[0:3] is controlled by 1DS[0:1] while the frequency of 2Q[0:5] is controlled by 2DS[0:1]. The phase of 1Q[0:1] is controlled by 1F[0:1], that of 1Q[2:3] is controlled by 1F[2:3] and that of 2Q[0:5] is controlled by 2F[0:1]. The high-fanout feedback output buffer (QF) may connect to the feedback input (FBK). This feedback output also has one phase function select input (FBF0) and two divider function selects FBDS[0:1]. The phase capabilities that are chosen by the phase function select pins are shown in Table 3. The divide capabilities for each bank are shown in Table 4. Table 3. Output Phase Select Control Signal 1F1 1F0 1F3 1F2 2F1 2F0 FBF0 LOW LOW LOW MID LOW HIGH MID LOW MID MID MID HIGH HIGH LOW HIGH MID HIGH HIGH Output Phase Function 1Q[0:1] 1Q[2:3] 2Q[0:5] –4tU –3tU –2tU –1tU 0tU +1tU +2tU +3tU +4tU –4tU –3tU –2tU –1tU 0tU +1tU +2tU +3tU +4tU QF –8tU –4tU –7tU N/A –6tU N/A BK1Q[0:1][2] N/A 0tU 0tU BK1Q[2:3][2] N/A +6tU N/A +7tU N/A +8tU +4tU Table 4. Output Divider Select Control Signal [1:2]DS1 [1:2]DS0 and FBDS1 and FBDS0 LOW LOW LOW MID LOW HIGH MID LOW MID MID MID HIGH HIGH LOW HIGH MID HIGH HIGH Output Divider Function Bank1 Bank2 Feedback /1 /2 /3 /4 /5 /6 /8 / 10 / 12 /1 /2 /3 /4 /5 /6 /8 / 10 / 12 /1 /2 /3 /4 /5 /6 /8 / 10 / 12 Figure 1 illustrates the timing relationship of programmable skew outputs. All times are measured with respect to REF with the output used for feedback programmed with 0tU skew. The PLL naturally aligns the rising edge of the FB input and REF input. If the output used for feedback is programmed to another skew position, then the whole tU matrix will shift with respect to REF. For example, if the output used for feedback is programmed to shift –4tU, then the whole matrix is shifted forward in time by 4tU. Thus an output programmed with 4tU of skew will effectively be skewed 8tU with respect to REF. Notes: 1. The level to be set on FS is determined by the “nominal” operating frequency (fNOM) of the VCO and Phase Generator. fNOM always appears on an output when the output is operating in the undivided mode. The REF and FB are at fNOM when the output connected to FB is undivided. 2. BK1Q denotes following the skew setting of indicated Bank1 outputs. Document #: 38-07336 Rev. *D Page 3 of 10 U t 0 +6t U U t 0 +5t t 0 +8t U t 0 +4t U U t 0 +3t t 0 +7t U t 0 +2t t 0 +1t t0 U U 0 t – 1t t 0 – 2t U t 0 – 3t U t 0 – 4t U t 0 – 5t U t 0 – 6t U t 0 – 7t U t 0 – 8t U RoboClock CY7B9945V FBInput REFInput 1F[0:3] 2F[0:3] (N/A) LL –8tU (N/A) LM –7tU (N/A) LH –6tU LL (N/A) –4tU LM (N/A) –3tU LH (N/A) –2tU ML (N/A) –1tU MM MM 0t U MH (N/A) +1t U HL (N/A) +2t U HM (N/A) +3t U HH (N/A) +4t U (N/A) HL +6t U (N/A) HM +7t U (N/A) HH +8t U Figure 1. Typical Outputs with FB Connected to a Zero-Skew Output[3] Output Disable Description The output of each output bank can be independently put into a HOLD-OFF or high-impedance state. The combination of the MODE and DIS[1:2] inputs determines the clock outputs’ state for each bank. When the DIS[1:2] is LOW, the outputs of the corresponding banks will be enabled. When DIS[1:2] is HIGH, the outputs for that bank will be disabled to a high-impedance (HI-Z) or HOLD-OFF state. Table 5 defines the disabled outputs functions. The HOLD-OFF state is intended to be a power saving feature. An output bank is disabled to the HOLD-OFF state in a maximum of six output clock cycles from the time when the disable input is HIGH. When disabled to the HOLD-OFF state, outputs are driven to a logic LOW state on their falling edges. This ensures the output clocks are stopped without a glitch. When a bank of outputs is disabled to HI-Z state, the respective bank of outputs will go HI-Z immediately. Table 5. DIS[1:2] Functionality MODE DIS[1:2] 1Q[0:3], 2Q[0:5] HIGH/LOW LOW ENABLED HIGH HIGH HI-Z LOW HIGH HOLD-OFF MID X FACTORY TEST Note: 3. FB connected to an output selected for “Zero” skew (i.e., FBF0 = MID or XF[1:0] = MID). Document #: 38-07336 Rev. *D Page 4 of 10 RoboClock CY7B9945V Lock Detect Output Description The LOCK detect output indicates the lock condition of the integrated PLL. Lock detection is accomplished by comparing the phase difference between the reference and feedback inputs. Phase error is declared when the phase difference between the two inputs is greater than the specified device propagation delay limit tPD. When in the locked state, after four or more consecutive feedback clock cycles with phase-errors, the LOCK output will be forced LOW to indicate out-of-lock state. When in the out-of-lock state, 32 consecutive phase-errorless feedback clock cycles are required to allow the LOCK output to indicate lock condition (LOCK = HIGH). f the feedback clock is removed after LOCK has gone HIGH, a “Watchdog” circuit is implemented to indicate the out-of-lock condition after a time-out period by deasserting LOCK LOW. This time out period is based upon a divided down reference clock. on the configurations of the divide, skew and frequency selection. All clock outputs will stay in High-Z mode and all FSMs will stay in the deterministic state until DIS2 is deasserted, which will cause the device to reenter factory test mode. Safe Operating Zone Figure 2 illustrates the operating condition at which the device does not exceed its allowable maximum junction temperature of 150°C. Figure 2 shows the maximum number of outputs that can operate at 185 MHz (with 25-pF load and no air flow) or 200 MHz (with 10-pF load and no air flow) at various ambient temperatures. At the limit line, all other outputs are configured to divide-by-two (i.e., operating at 92.5 MHz) or lower frequencies. The device will operate below maximum allowable junction temperature of 150°C when its configuration (with the specified constraints) falls within the shaded region (safe operating zone). Figure 2 shows that at 85°C, the maximum number of outputs that can operate at 200 MHz is 6. This assumes that there is activity on the selected REF input. If there is no activity on the selected REF input then the LOCK detect pin may not accurately reflect the state of the internal PLL. Typical Safe Operating Zone (25-pF Load, 0-m/s air flow) Factory Test Mode Description When in the test mode, the device can be reset to a deterministic state by driving the DIS2 input HIGH. Doing so will cause all outputs to disable and after the selected reference clock pin has five positive transitions, all internal finite state machines (FSM) to be set a deterministic state. The states will depend Document #: 38-07336 Rev. *D Ambient Temperature (C) The device will enter factory test mode when the MODE is driven to MID. In factory test mode, the device will operate with its internal PLL disconnected; input level supplied to the reference input will be used in place of the PLL output. In TEST mode the FB input must be tied LOW. All functions of the device are still operational in factory test mode except the internal PLL and output bank disables. The MODE input is designed to be a static input. Dynamically toggling this input from LOW to HIGH may temporarily cause the device to go into factory test mode (when passing through the MID state). 100 95 90 85 80 75 70 Safe Operating Zone 65 60 55 50 2 4 6 8 10 Number of Outputs at 185 MHz Figure 2. Typical Safe Operating Zone Page 5 of 10 RoboClock CY7B9945V Absolute Maximum Conditions (Above which the useful life may be impaired. For user guidelines, not tested.) Storage Temperature .................................–40°C to +125°C Output Current into Outputs (LOW)............................. 40 mA Static Discharge Voltage........................................... > 1100V (per MIL-STD-883, Method 3015) Latch-up Current.................................................. > ± 200 mA Operating Range Ambient Temperature with Power Applied ..................................... –40°C to +125°C Range Supply Voltage to Ground Potential ............... –0.5V to +4.6V Commercial DC Input Voltage......................................–0.3V to VCC+0.5V Industrial Ambient Temperature VCC 0°C to +70°C 3.3V ±10% –40°C to +85°C 3.3V ±10% Electrical Characteristics Over the Operating Range Parameter Description LVTTL-compatible Output Pins (1Q[0:3],2Q[0:5]) Test Conditions Min. Max. Unit 2.4 2.4 – – V V – – 0.5 0.5 V V –100 100 µA 2.0 –0.3 VCC + 0.3 0.8 V V – – 100 500 µA µA –500 – µA Min. < VCC < Max. 0.87 * VCC – V 0.47 * VCC 0.53 * VCC – 0.13 * VCC – 200 – 400 VOH LVTTL HIGH Voltage (QF, 1Q[0:3], 2Q[0:5]) LOCK VCC = Min., IOH = –30 mA IOH = –2 mA, VCC = Min. VOL LVTTL LOW Voltage (QF, 1Q[0:3], 2Q[0:5]) LOCK VCC = Min., IOL= 30 mA IOL= 2 mA, VCC = Min. High-impedance State Leakage Current IOZ LVTTL-compatible Input Pins (FBK, REF±, DIS[1:2],REFSEL) VIH VIL LVTTL Input HIGH LVTTL Input LOW Min. < VCC < Max. Min. < VCC < Max. II IlH LVTTL VIN >VCC LVTTL Input HIGH Current VCC = GND, VIN = 3.63V VCC = Max., VIN = VCC LVTTL Input LOW Current VCC = Max., VIN = GND IlL Three-level Input Pins (FS[0:2], 1F[0:3], 2F[0:1], [1:2]DS[0:1], FBFO, FBDS[0:1],MODE) VIHH Three-level Input HIGH[4] MID[4] VIMM VILL Three-level Input Three-level Input LOW[4] Min. < VCC < Max. Min. < VCC < Max. IIHH Three-level Input HIGH FS[0:2],IF[0:3],FBDS[0:1] Current 2F[0:1],[1:2]DS[0:1],FBFO VIN = VCC IIMM Three-level Input MID Current VIN = VCC/2 –50 –100 50 100 µA µA IILL Three-level Input LOW FS[0:2],IF[0:3],FBDS[0:1] Current 2F[0:1],[1:2]DS[0:1],FBFO VIN = GND –200 –400 – – µA µA FS[0:2],IF[0:3],FBDS[0:1] 2F[0:1],[1:2]DS[0:1],FBFO LVDIFF Input Pins (REF[A:B]±) VDIFF Input Differential Voltage V V µA µA 400 VCC mV Highest Input HIGH Voltage Lowest Input LOW Voltage 1.0 GND VCC VCC – 0.4 V V Common Mode Range (Crossing Voltage) VCOM Operating Current 0.8 VCC – 0.2 V VIHHP VILLP ICCI ICCN Internal Operating Current Output Current Dissipation/Pair[6] CY7B9945V VCC = Max., fMAX[5] – 250 mA CY7B9945V VCC = Max., CLOAD = 25 pF, RLOAD = 50Ω at VCC/2, fMAX – 40 mA Note: 4. These inputs are normally wired to VCC, GND, or left unconnected (actual threshold voltages vary as a percentage of VCC). Internal termination resistors hold the unconnected inputs at VCC/2. If these inputs are switched, the function and timing of the outputs may glitch and the PLL may require an additional tLOCK time before all data sheet limits are achieved. 5. ICCI measurement is performed with Bank1 and FB Bank configured to run at maximum frequency (fNOM = 200 MHz) and the other output bank to run at half the maximum frequency. FS is asserted to the HIGH state. 6. This is dependent upon frequency and number of outputs of a bank being loaded. The value indicates maximum ICCN at maximum frequency and maximum load of 25 pF terminated to 50Ω at VCC/2. Document #: 38-07336 Rev. *D Page 6 of 10 RoboClock CY7B9945V Capacitance Parameter CIN Description Test Conditions Min. Max. Unit – 5 pF TA = 25°C, f = 1 MHz, VCC = 3.3V Input Capacitance Switching Characteristics Over the Operating Range [7, 8, 9, 10, 11] CY7B9945V-2 CY7B9945V-5 Min. Max. Min. Max. Unit fin Parameter Clock Input Frequency Description 24 200 24 200 MHz fout Clock Output Frequency 24 200 24 200 MHz tSKEWPR Matched-Pair Skew[12, 13],1Q[0:1],1Q[2:3],2Q[0:1],2Q[2:3],2Q[4:5] – 200 – 200 ps Skew[12, 13] tSKEWBNK Intrabank – 250 – 250 ps tSKEW0 Output-Output Skew (same frequency and phase, rise to rise, fall to fall)[12, 13] – 250 – 550 ps tSKEW1 Output-Output Skew (same frequency and phase, other banks at different frequency, rise to rise, fall to fall)[12, 13] – 250 – 650 ps tSKEW2 Output-Output Skew (all output configurations outside of tSKEW0 and tSKEW1)[12, 13] – 500 – 800 ps tCCJ1-3 Cycle-to-Cycle Jitter (divide by 1 output frequency, FB = divide by 1, 2, 3) – 150 – 150 ps PeakPeak tCCJ4-12 Cycle-to-Cycle Jitter (divide by 1 output frequency, FB = divide by 4, 5, 6, 8, 10, 12) – 100 – 100 ps PeakPeak tPD Propagation Delay, REF to FB Rise –250 250 –500 500 ps TTB Total Timing Budget window (same frequency and phase)[14, 15] – 500 – 700 ps tPDDELTA Propagation Delay difference between two devices[16] – 200 – 200 ps tREFpwh REF input (Pulse Width HIGH)[5] 2.0 – 2.0 – ns tREFpwl REF input (Pulse Width LOW)[5] tr/tf Output Rise/Fall Time[17] tLOCK PLL Lock TIme From Power-Up – 10 tRELOCK1 PLL Relock Time (from same frequency, different phase) with Stable Power Supply – 500 tRELOCK2 PLL Re-Lock Time (from different frequency, different phase) with Stable Power Supply[18] – 1000 tODCV Output duty cycle deviation from 50%[11] 2.0 – 2.0 – ns 0.15 2.0 0.15 2.0 ns – 10 ms – 500 µs – 1000 µs –1.0 1.0 –1.0 1.0 ns tPWH Output HIGH time deviation from 50% [19] – 1.5 – 1.5 ns tPWL Output LOW time deviation from 50%[19] – 2.0 – 2.0 ns reference[20] tPDEV Period deviation when changing from reference to – 0.025 – 0.025 UI tOAZ DIS[1:2] HIGH to output high-impedance from ACTIVE[12, 21] 1.0 10 1.0 10 ns tOZA DIS[1:2] LOW to output ACTIVE from output is high-impedance[21, 22] 0.5 14 0.5 14 ns Notes: 7. This is for non-three-level inputs. 8. Assumes 25 pF Max. Load Capacitance up to 185 MHz. At 200 MHz the max. load is 10 pF. 9. Both outputs of pair must be terminated, even if only one is being used. 10. Each package must be properly decoupled. 11. AC parameters are measured at 1.5V, unless otherwise indicated. 12. Test Load CL= 25 pF, terminated to VCC/2 with 50Ω up to185 MHz and 10-pF load to 200 MHz. 13. SKEW is defined as the time between the earliest and the latest output transition among all outputs for which the same phase delay has been selected when all outputs are loaded with 25 pF and properly terminated up to 185 MHz. At 200 MHz the max load is 10 pF. 14. Tested initially and after any design or process changes that may affect these parameters. 15. TTB is the window between the earliest and the latest output clocks with respect to the input reference clock across variations in output frequency, supply voltage, operating temperature, input clock edge rate, and process. The measurements are taken with the AC test load specified and include output-output skew, cycle-cycle jitter, and dynamic phase error. TTB will be equal to or smaller than the maximum specified value at a given output frequency. 16. Guaranteed by statistical correlation. Tested initially and after any design or process changes that may affect these parameters. 17. Rise and fall times are measured between 2.0V and 0.8V. 18. fNOM must be within the frequency range defined by the same FS state. 19. tPWH is measured at 2.0V. tPWL is measured at 0.8V. Document #: 38-07336 Rev. *D Page 7 of 10 RoboClock CY7B9945V AC Test Loads and Waveforms[23] 3.3V R1 For LOCK output only R1 = 910 Ω R2 = 910 Ω CL < 30 pF For all other outputs OUTPUT R1 = 100Ω CL R2 = 100Ω CL < 25 pF to 185 MHz or 10 pF at 200 MHz (Includes fixture and probe capacitance) R2 (a) LVTTL AC Test Load 3.3V 2.0V 2.0V 0.8V GND 0.8V < 1 ns < 1 ns (b) TTL Input Test Waveform AC Timing Diagram tREFpwl tREFpwh [1:2]Q[0,2] REF t SKEWPR t SKEWPR t PWH tPD t PWL [1:2]Q[1,3] 2.0V FB 0.8V tCCJ1-3,4-12 Q [1:2]Q[0:3] t SKEWBNK t SKEWBNK [1:2]Q[0:3] REF TO DEVICE 1 and 2 tODCV tODCV tPD Q FB DEVICE1 tPDELTA tPDELTA t SKEW0,1 t SKEW0,1 Other Q FB DEVICE2 Notes: 20. UI = unit interval. Examples: 1 UI is a full period. 0.1UI is 10% of period. 21. Measured at 0.5V deviation from starting voltage. 22. For tOZA minimum, CL = 0 pF. For tOZA maximum, CL= 25 pF to 185 MHz or 10 pF to 200 MHz. 23. These figures are for illustration purposes only. The actual ATE loads may vary. Document #: 38-07336 Rev. *D Page 8 of 10 RoboClock CY7B9945V Ordering Information Propagation Delay (ps) Max. Speed (MHz) Ordering Code Package Name Package Type 250 200 CY7B9945V-2AC A52 52-lead Thin Quad Flat Pack Operating Range Commercial 500 200 CY7B9945V-5AC A52 52-lead Thin Quad Flat Pack Commercial 250 200 CY7B9945V-2AI A52 52-lead Thin Quad Flat Pack Industrial 500 200 CY7B9945V-5AI A52 52-lead Thin Quad Flat Pack Industrial Package Diagram 52-lead Thin Plastic Quad Flat Pack (10 × 10 × 1.4 mm) A52 51-85131-** RoboClock is a registered trademark, and Total Timing Budget and TTB are trademarks, of Cypress Semiconductor. All product and company names mentioned in this document are the trademarks of their respective holders. Document #: 38-07336 Rev. *D Page 9 of 10 © Cypress Semiconductor Corporation, 2003. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges. RoboClock CY7B9945V Document History Page Document Title: CY7B9945V RoboClock High-speed Multi-phase PLL Clock Buffer Document Number: 38-07336 REV. ECN NO. Issue Date Orig. of Change Description of Change ** 111747 03/04/02 CTK New Data Sheet *A 116572 09/05/02 HWT Added TTB Features *B 119078 10/16/02 HWT Corrected the following items in the Electrical Characteristics table: IIIL,IIIH,IIIM specifications from: three-level input pins excluding FBFO to FS[0:2],IF[0:3],FBDS[0:1] and FBFO to 2F[0:1],[1:2]DS[0:1],FBFO Common Mode Range (VCOM) from VCC to VCC–0.2 Corrected typo TQFP to LQFP in Features *C 124645 03/20/03 RGL Corrected typo LQFP to TQFP in Features *D 128464 07/25/03 RGL Added clock input frequency (fin) specifications in the switching characteristics table. Document #: 38-07336 Rev. *D Page 10 of 10