140PC...-PCB Series Signal conditioned precision pressure transducers FEATURES · 1 to 150 psi absolute, gage or differential pressure (custom calibrations available) · 1...6 V output · Output ratiometric to supply voltage · Precision temperature compensated and calibrated · Special calibrations for small volumes on request · EMC-proof SERVICE Scale: Non-corrosive, non-ionic working fluids, such as dry air and dry gases SPECIFICATIONS 1 cm 1 inch ELECTRICAL CONNECTION Maximum ratings Supply voltage Maximum load current Source Sink Temperature limits Storage Operating Compensated Lead temperature (10 sec. soldering) Humidity limits Pressure inlets only Proof pressure1 All 1 psi, 3 psi, 5 psi devices All 15 psi devices All 30 psi devices All 100 psi devices All 150 psi devices March 2006 / 554 7...16 V 10 mA 5 mA +Vs -55 to 100°C -40 to 85°C 0 to 70°C 140PC...-PCB 7 V to 16 V (NOM 8.00 V) Vout 300°C V -Vs 0 - 98 %RH 20 psi 30 psi 60 psi 150 psi 200 psi 1/4 www.sensortechnics.com 140PC...-PCB Series Signal conditioned precision pressure transducers PERFORMANCE CHARACTERISTICS Ω, tamb = 25°C) (unless otherwise noted VS = 8.00 ±0.01 V, RL > 100 kΩ Characteristics Operating pressure vacuum gage devices2 differential devices3 absolute devices3 pressure/vacuum devices3 Zero pressure offset Full scale span4 Min. 141PC01G-PCB 141PC05G-PCB 141PC15G-PCB 141PC30G-PCB 141PC100G-PCB 142PC01D-PCB 142PC05D-PCB 142PC15D-PCB 142PC30D-PCB 142PC100D-PCB 142PC150D-PCB 142PC15A-PCB 142PC30A-PCB 142PC100A-PCB 143PC01D-PCB 143PC03D-PCB 143PC05D-PCB 143PC15D-PCB 141PC.../142PC...-PCB 143PC...-PCB 141PC.../142PC...-PCB 143PC...-PCB Full scale output Output at lowest specified pressure Non-linearity and hysteresis (BSL)5 Thermal effects6 Combined offset and span (0 to 70°C) Long term stability7 -1 -5 -15 -30 -100 0 0 0 0 0 0 0 0 0 -1 -2.5 -5 -15 0.95 3.45 4.95 2.45 5.90 Max. 1.00 3.50 5.00 2.50 6.00 0 0 0 0 0 1 5 15 30 100 150 15 30 100 1 2.5 5 15 1.05 3.55 5.05 2.55 6.10 143PC...-PCB 1.00 all 1 psi devices all others 0.1 ±1.5 ±0.5 ±0.1 Response time (10 to 90%) Current consumption Radiated, radio frequency electromagnetic field immunity (RFI) EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) Typ. 0.1 4.5 10 0.5 ±3.0 ±1.0 Unit p si g (vacuum) psid(g) p si a psid(g) V %FSO ms mA V/m Specification notes: 1. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 2. The output signal of all 141PC...-PCB devices is proportional to the vacuum applied to port A, relative to port B, e. g. the output signal increases when pressure is applied to port B relative to port A. 3. The output signal of all 142PC...D-PCB and 143PC...D-PCB devices is proportional to the pressure applied to port A, relative to port B, e.g. the output signal increases when vacuum is applied to port B relative to port A. 4. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset. 5. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure. 6. Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C. 7. Change in output after one year or 1 million pressure cycles. 2/4 March 2006 / 554 www.sensortechnics.com 140PC...-PCB Series Signal conditioned precision pressure transducers OUTPUT CHARACTERISTICS Vacuum gage devices 141PC...-PCB Differential devices 142PC...-PCB 6 6 Vout 5 V Vout 5 V 4 4 3 3 2 2 1 1 -100 -80 -60 -40 -20 0 % full scale pressure (vacuum) 0 20 40 60 80 100 % full scale pressure Pressure/vacuum devices 143PC...-PCB 6 Vout 5 V 4 3.5V 3 2 1 0 -100 March 2006 / 554 -50 0 50 100 % full scale pressure 3/4 www.sensortechnics.com 140PC...-PCB Series Signal conditioned precision pressure transducers OUTLINE DRAWING 30.0 port A (high pressure) 31.5 2 x 5.08 typ. 9.1 3 terminals 0.56 diam. 10.7 4.8 diam. 3,4 3.2 diam. 2 x mounting holes 22.7 52.4 59.8 18.3 14.0 NOM 6.0 pin 1 2 3 mass: 20 g 1 2 3 12.6 connection +Vs -Vs Vout dimensions in mm ORDERING INFORMATION Operating pressure part number Vacuum gage devices 0 to -1 psig 0 to -5 psig 0 to -15 psig 0 to -30 psig 0 to -100 psig 141PC01G-PCB 141PC05G-PCB 141PC15G-PCB 141PC30G-PCB 141PC100G-PCB Differential / gage devices 0 to 1 psid(g) 0 to 5 psid(g) 0 to 15 psid(g) 0 to 30 psid(g) 0 to 100 psid(g) 0 to 150 psid(g) 142PC01D-PCB 142PC05D-PCB 142PC15D-PCB 142PC30D-PCB 142PC100D-PCB 142PC150D-PCB Absolute devices 0 to 15 psia 0 to 30 psia 0 to 100 psia 142PC15A-PCB 142PC30A-PCB 142PC100A-PCB Pressure/vacuum devices 0 to ±1 psid(g) 0 to ±2.5 psid(g) 0 to ±5 psid(g) 0 to ±15 psid(g) 143PC01D-PCB 143PC03D-PCB 143PC05D-PCB 143PC15D-PCB Custom calibrations available Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 4/4 March 2006 / 554 www.sensortechnics.com