SENSORTECHNICS 143PC03D-PCB

140PC...-PCB Series
Signal conditioned precision pressure transducers
FEATURES
· 1 to 150 psi
absolute, gage or differential pressure
(custom calibrations available)
· 1...6 V output
· Output ratiometric to supply voltage
· Precision temperature compensated
and calibrated
· Special calibrations for small
volumes on request
· EMC-proof
SERVICE
Scale:
Non-corrosive, non-ionic working fluids,
such as dry air and dry gases
SPECIFICATIONS
1 cm
1 inch
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage
Maximum load current
Source
Sink
Temperature limits
Storage
Operating
Compensated
Lead temperature
(10 sec. soldering)
Humidity limits
Pressure inlets only
Proof pressure1
All 1 psi, 3 psi, 5 psi devices
All 15 psi devices
All 30 psi devices
All 100 psi devices
All 150 psi devices
March 2006 / 554
7...16 V
10 mA
5 mA
+Vs
-55 to 100°C
-40 to 85°C
0 to 70°C
140PC...-PCB
7 V to 16 V
(NOM 8.00 V)
Vout
300°C
V
-Vs
0 - 98 %RH
20 psi
30 psi
60 psi
150 psi
200 psi
1/4
www.sensortechnics.com
140PC...-PCB Series
Signal conditioned precision pressure transducers
PERFORMANCE CHARACTERISTICS
Ω, tamb = 25°C)
(unless otherwise noted VS = 8.00 ±0.01 V, RL > 100 kΩ
Characteristics
Operating pressure
vacuum gage devices2
differential devices3
absolute devices3
pressure/vacuum devices3
Zero pressure offset
Full scale span4
Min.
141PC01G-PCB
141PC05G-PCB
141PC15G-PCB
141PC30G-PCB
141PC100G-PCB
142PC01D-PCB
142PC05D-PCB
142PC15D-PCB
142PC30D-PCB
142PC100D-PCB
142PC150D-PCB
142PC15A-PCB
142PC30A-PCB
142PC100A-PCB
143PC01D-PCB
143PC03D-PCB
143PC05D-PCB
143PC15D-PCB
141PC.../142PC...-PCB
143PC...-PCB
141PC.../142PC...-PCB
143PC...-PCB
Full scale output
Output at lowest specified pressure
Non-linearity and hysteresis (BSL)5
Thermal effects6
Combined offset and span (0 to 70°C)
Long term stability7
-1
-5
-15
-30
-100
0
0
0
0
0
0
0
0
0
-1
-2.5
-5
-15
0.95
3.45
4.95
2.45
5.90
Max.
1.00
3.50
5.00
2.50
6.00
0
0
0
0
0
1
5
15
30
100
150
15
30
100
1
2.5
5
15
1.05
3.55
5.05
2.55
6.10
143PC...-PCB
1.00
all 1 psi devices
all others
0.1
±1.5
±0.5
±0.1
Response time (10 to 90%)
Current consumption
Radiated, radio frequency electromagnetic
field immunity (RFI) EN6100-4-3 grade 3,
80 to 1000 MHz,
80 % AMC (1 KHz)
Typ.
0.1
4.5
10
0.5
±3.0
±1.0
Unit
p si g
(vacuum)
psid(g)
p si a
psid(g)
V
%FSO
ms
mA
V/m
Specification notes:
1. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
2. The output signal of all 141PC...-PCB devices is proportional to the vacuum applied to port A, relative to port B, e. g. the
output signal increases when pressure is applied to port B relative to port A.
3. The output signal of all 142PC...D-PCB and 143PC...D-PCB devices is proportional to the pressure applied to port A, relative
to port B, e.g. the output signal increases when vacuum is applied to port B relative to port A.
4. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.
5. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.
6. Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.
7. Change in output after one year or 1 million pressure cycles.
2/4
March 2006 / 554
www.sensortechnics.com
140PC...-PCB Series
Signal conditioned precision pressure transducers
OUTPUT CHARACTERISTICS
Vacuum gage devices
141PC...-PCB
Differential devices
142PC...-PCB
6
6
Vout
5
V
Vout
5
V
4
4
3
3
2
2
1
1
-100
-80
-60
-40
-20
0
% full scale pressure (vacuum)
0
20
40
60
80
100
% full scale pressure
Pressure/vacuum devices
143PC...-PCB
6
Vout
5
V
4
3.5V
3
2
1
0
-100
March 2006 / 554
-50
0
50
100
% full scale pressure
3/4
www.sensortechnics.com
140PC...-PCB Series
Signal conditioned precision pressure transducers
OUTLINE DRAWING
30.0
port A
(high pressure)
31.5
2 x 5.08 typ.
9.1
3 terminals
0.56 diam.
10.7
4.8
diam.
3,4
3.2 diam.
2 x mounting holes
22.7
52.4
59.8
18.3
14.0
NOM 6.0
pin
1
2
3
mass: 20 g
1
2
3
12.6
connection
+Vs
-Vs
Vout
dimensions in mm
ORDERING INFORMATION
Operating pressure
part number
Vacuum gage devices
0 to -1 psig
0 to -5 psig
0 to -15 psig
0 to -30 psig
0 to -100 psig
141PC01G-PCB
141PC05G-PCB
141PC15G-PCB
141PC30G-PCB
141PC100G-PCB
Differential / gage devices
0 to 1 psid(g)
0 to 5 psid(g)
0 to 15 psid(g)
0 to 30 psid(g)
0 to 100 psid(g)
0 to 150 psid(g)
142PC01D-PCB
142PC05D-PCB
142PC15D-PCB
142PC30D-PCB
142PC100D-PCB
142PC150D-PCB
Absolute devices
0 to 15 psia
0 to 30 psia
0 to 100 psia
142PC15A-PCB
142PC30A-PCB
142PC100A-PCB
Pressure/vacuum devices
0 to ±1 psid(g)
0 to ±2.5 psid(g)
0 to ±5 psid(g)
0 to ±15 psid(g)
143PC01D-PCB
143PC03D-PCB
143PC05D-PCB
143PC15D-PCB
Custom calibrations available
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
4/4
March 2006 / 554
www.sensortechnics.com