OMRON G3VM

MOS FET Relays
G3VM-61G2
Ultrasensitive MOS FET Relays in 60 V Load
series for power savings, SOP Package.
• Trigger LED forward current of 1 mA (maximum)
facilitates power saving designs and prolonged battery life.
• Continuous load current of 400 mA.
• RoHS Compliant
■ Application Examples
• Broadband systems and Measurement devices
• Security systems
• Industrial equipment
• Battery powered equipment and Amusement machines
Note: The actual product is marked differently from the image shown
here.
■ List of Models
Contact form
SPST-NO
Load voltage (peak value)
(See the note.)
Terminals
Surface-mounting
terminals
Model
60 V
Number per stick
Number per tape
G3VM-61G2
100
---
G3VM-61G2(TR)
---
2,500
Note: The AC peak and DC value are given for the load voltage.
■ Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3VM-61G2
4.4±0.25
3.9±0.25
2.1 max.
0.15
Note: The actual product is marked differently
from the image shown here.
0.4±0.1
0.6±0.3
0.1±0.1
7.0±0.4
2.54±0.25
Weight: 0.1 g
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-61G2
4
4
3
3
Mold pin mark
OMRON logo
Model name
LOT No.
Pin 1 mark
1
1
2
2
Note: The actual product is marked differently
from the image shown here.
■ Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-61G2
6 to 6.3
1.2
0.8
2.54
MOS FET Relays
G3VM-61G2
125
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input
Symbol
Rating
Unit
Measurement Conditions
LED forward current
IF
50
mA
Repetitive peak LED
forward current
IFP
1
A
100 μs pulses, 100 pps
LED forward current
reduction rate
Δ IF/°C
−0.5
mA/°C
Ta ≥ 25°C
LED reverse voltage
VR
5
V
Note:
Tj
125
°C
VOFF
60
V
Continuous load current
(AC peak/DC)
IO
400
mA
ON current reduction rate
Δ IO/°C
−4.0
mA/°C
Connection temperature
Tj
125
°C
Dielectric strength between input and VI-O
output (See note 1.)
1,500
Vrms
AC for 1 min
Connection temperature
Output Load voltage (AC peak/DC)
1. The dielectric strength between the input and
output was checked by applying voltage between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Ta ≥ 25°C
Operating temperature
Ta
−40 to +85
°C
With no icing or condensation
Storage temperature
Tstg
−55 to +125 °C
With no icing or condensation
Soldering temperature (10 s)
---
260
°C
10 s
■ Electrical Characteristics (Ta = 25°C)
Item
Input
Minimum
Symbol
Typical
Maximum
Measurement
conditions
Unit
LED forward voltage
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
μA
VR = 5 V
Capacity between terminals
CT
---
30
---
pF
V = 0, f = 1 MHz
IFT
---
0.4
1
mA
IO = 400 mA
RON
---
1
2
Ω
IF = 2 mA,
IO = 400 mA
Current leakage when the relay is open ILEAK
---
1
1000
nA
VOFF = 60 V
Capacity between terminals
---
130
---
pF
V = 0, f = 1MHz
Trigger LED forward current
Output Maximum resistance with output ON
COFF
CI-O
---
0.8
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance
RI-O
1,000
---
---
MΩ
VI-O = 500 VDC,
RoH ≤ 60%
Turn-ON time
tON
---
3
8
ms
Turn-OFF time
tOFF
---
1
3
ms
IF = 2 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
VDD
---
---
48
Operating LED forward current
Unit
V
IF
---
2
25
mA
Continuous load current (AC peak/DC) IO
---
---
320
mA
Operating temperature
− 20
---
65
°C
126
Ta
MOS FET Relays
G3VM-61G2
2. Turn-ON and Turn-OFF
Times
IF
Capacity between I/O terminals
Load voltage (AC peak/DC)
Note:
1
4
2
3
RL
VDD
VOUT
IF
VOUT
10%
t ON
90%
t OFF
■ Engineering Data
LED forward current vs.
Ambient temperature
Continuous load current vs.
Ambient temperature
IO - Ta
50
40
30
20
10
0
-20
0
20
40
60
80
400
300
200
100
00
100
Ambient temperature Ta (ഒ)
-20
0
IO - VON
On-state resistance RON (Ω)
40
60
80
100
200
100
0
-100
-200
-300
-500
0.4
0.2
0
0.2
0.4
-40
-20
0
20
40
IO = 400mA
IF = 2mA
t < 1s
60
80
100
Turn ON, Turn OFF time tON, tOFF (mS)
tOFF
1
0.1
tON
1
0.7
0.6
0.5
0.4
0.3
0.2
0.1
IO = 400mA
t < 1s
0
0.0
-40
-20
10
LED forward current IF (mA)
100
tON
1
tOFF
0.1
-40
-20
0
20
40
0
20
40
60
80
100
I LEAK - Ta
tON, tOFF - Ta
V DD = 20V
R L = 200 Ω
IF = 2mA
1.4
Current leakage vs.
Ambient temperature
10
10
1.3
Ambient temperature Ta (ഒ)
Turn ON, Turn OFF time vs.
Ambient temperature
tON, tOFF - IF
1.2
0.8
Ambient temperature Ta (ഒ)
100
1.1
IFT - Ta
0.6
Turn ON, Turn OFF time vs.
LED forward current
0.1
1.0
Trigger LED forward current vs.
Ambient temperature
0.8
0.0
0
0.01
0.9
LED forward voltage VF (V)
1.0
-400
V DD = 20V
R L = 200 Ω
T a = 25 ഒ
0.8
Current leakage ILEAK (nA)
Continuous load current IO (mA)
Ta = 25 ഒ
IF = 2mA
-0.2
1
RON - Ta
On-state voltage VON (V)
Turn ON, Turn OFF time tON, tOFF (mS)
20
1.2
-0.4
10
On-state resistance vs.
Ambient temperature
500
300
Ta = 25ഒ
Ambient temperature Taഒ
Continuous load current vs.
On-state voltage
400
100
0.1
-40
Trigger LED forward current I F T (mA)
-40
IF - VF
500
LED forward current I F (mA)
60
Continuous load current I O (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs.
LED forward voltage
60
80
100
100
VOFF = 60V
10
1
0.1
0.01
0.001
-40
Ambient temperature Ta (ഒ
MOS FET Relays
-20
0
20
40
60
80
100
Ambient temperature Ta (ഒ)
G3VM-61G2
127
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X302-E-1
MOS FET Relays
12/10
Specifications subject to change without notice
G3VM-61G2