MOS FET Relays G3VM-61G2 Ultrasensitive MOS FET Relays in 60 V Load series for power savings, SOP Package. • Trigger LED forward current of 1 mA (maximum) facilitates power saving designs and prolonged battery life. • Continuous load current of 400 mA. • RoHS Compliant ■ Application Examples • Broadband systems and Measurement devices • Security systems • Industrial equipment • Battery powered equipment and Amusement machines Note: The actual product is marked differently from the image shown here. ■ List of Models Contact form SPST-NO Load voltage (peak value) (See the note.) Terminals Surface-mounting terminals Model 60 V Number per stick Number per tape G3VM-61G2 100 --- G3VM-61G2(TR) --- 2,500 Note: The AC peak and DC value are given for the load voltage. ■ Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-61G2 4.4±0.25 3.9±0.25 2.1 max. 0.15 Note: The actual product is marked differently from the image shown here. 0.4±0.1 0.6±0.3 0.1±0.1 7.0±0.4 2.54±0.25 Weight: 0.1 g ■ Terminal Arrangement/Internal Connections (Top View) G3VM-61G2 4 4 3 3 Mold pin mark OMRON logo Model name LOT No. Pin 1 mark 1 1 2 2 Note: The actual product is marked differently from the image shown here. ■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-61G2 6 to 6.3 1.2 0.8 2.54 MOS FET Relays G3VM-61G2 125 ■ Absolute Maximum Ratings (Ta = 25°C) Item Input Symbol Rating Unit Measurement Conditions LED forward current IF 50 mA Repetitive peak LED forward current IFP 1 A 100 μs pulses, 100 pps LED forward current reduction rate Δ IF/°C −0.5 mA/°C Ta ≥ 25°C LED reverse voltage VR 5 V Note: Tj 125 °C VOFF 60 V Continuous load current (AC peak/DC) IO 400 mA ON current reduction rate Δ IO/°C −4.0 mA/°C Connection temperature Tj 125 °C Dielectric strength between input and VI-O output (See note 1.) 1,500 Vrms AC for 1 min Connection temperature Output Load voltage (AC peak/DC) 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Ta ≥ 25°C Operating temperature Ta −40 to +85 °C With no icing or condensation Storage temperature Tstg −55 to +125 °C With no icing or condensation Soldering temperature (10 s) --- 260 °C 10 s ■ Electrical Characteristics (Ta = 25°C) Item Input Minimum Symbol Typical Maximum Measurement conditions Unit LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Reverse current IR --- --- 10 μA VR = 5 V Capacity between terminals CT --- 30 --- pF V = 0, f = 1 MHz IFT --- 0.4 1 mA IO = 400 mA RON --- 1 2 Ω IF = 2 mA, IO = 400 mA Current leakage when the relay is open ILEAK --- 1 1000 nA VOFF = 60 V Capacity between terminals --- 130 --- pF V = 0, f = 1MHz Trigger LED forward current Output Maximum resistance with output ON COFF CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V Insulation resistance RI-O 1,000 --- --- MΩ VI-O = 500 VDC, RoH ≤ 60% Turn-ON time tON --- 3 8 ms Turn-OFF time tOFF --- 1 3 ms IF = 2 mA, RL = 200 Ω, VDD = 20 V (See note 2.) ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum VDD --- --- 48 Operating LED forward current Unit V IF --- 2 25 mA Continuous load current (AC peak/DC) IO --- --- 320 mA Operating temperature − 20 --- 65 °C 126 Ta MOS FET Relays G3VM-61G2 2. Turn-ON and Turn-OFF Times IF Capacity between I/O terminals Load voltage (AC peak/DC) Note: 1 4 2 3 RL VDD VOUT IF VOUT 10% t ON 90% t OFF ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 50 40 30 20 10 0 -20 0 20 40 60 80 400 300 200 100 00 100 Ambient temperature Ta (ഒ) -20 0 IO - VON On-state resistance RON (Ω) 40 60 80 100 200 100 0 -100 -200 -300 -500 0.4 0.2 0 0.2 0.4 -40 -20 0 20 40 IO = 400mA IF = 2mA t < 1s 60 80 100 Turn ON, Turn OFF time tON, tOFF (mS) tOFF 1 0.1 tON 1 0.7 0.6 0.5 0.4 0.3 0.2 0.1 IO = 400mA t < 1s 0 0.0 -40 -20 10 LED forward current IF (mA) 100 tON 1 tOFF 0.1 -40 -20 0 20 40 0 20 40 60 80 100 I LEAK - Ta tON, tOFF - Ta V DD = 20V R L = 200 Ω IF = 2mA 1.4 Current leakage vs. Ambient temperature 10 10 1.3 Ambient temperature Ta (ഒ) Turn ON, Turn OFF time vs. Ambient temperature tON, tOFF - IF 1.2 0.8 Ambient temperature Ta (ഒ) 100 1.1 IFT - Ta 0.6 Turn ON, Turn OFF time vs. LED forward current 0.1 1.0 Trigger LED forward current vs. Ambient temperature 0.8 0.0 0 0.01 0.9 LED forward voltage VF (V) 1.0 -400 V DD = 20V R L = 200 Ω T a = 25 ഒ 0.8 Current leakage ILEAK (nA) Continuous load current IO (mA) Ta = 25 ഒ IF = 2mA -0.2 1 RON - Ta On-state voltage VON (V) Turn ON, Turn OFF time tON, tOFF (mS) 20 1.2 -0.4 10 On-state resistance vs. Ambient temperature 500 300 Ta = 25ഒ Ambient temperature Taഒ Continuous load current vs. On-state voltage 400 100 0.1 -40 Trigger LED forward current I F T (mA) -40 IF - VF 500 LED forward current I F (mA) 60 Continuous load current I O (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 60 80 100 100 VOFF = 60V 10 1 0.1 0.01 0.001 -40 Ambient temperature Ta (ഒ MOS FET Relays -20 0 20 40 60 80 100 Ambient temperature Ta (ഒ) G3VM-61G2 127 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X302-E-1 MOS FET Relays 12/10 Specifications subject to change without notice G3VM-61G2 Printed in USA