POWERDYNAMICS HGN-375A01W-20-2D

HGN-375(A, B, C) FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS (Unit: mm)
CASE A
60.71
49.83
55.04
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
65.4
60.0
O
32.45
3.5
40 +- 0.2
49.37
28.5
29.5
40.0+- 0.2
4x R0.5
6.30 TYP.
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
48.7
* Medical application
(3.5)
2x 3.5
29 6.3 TYP.
29.3+0.5
60.8+0.5
72.0+0.1
CASE C
(61.3)
(56.2)
TECHNICAL DATA
• Rated Voltage: 125/250VAC
• Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2µA*, max
@ 250VAC 50Hz: 5µA*, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
59.8
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
48.7
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
(3.5)
R2.5 TYP.
29 6.3 TYP.
29.3+0.5
61.4+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com • www.powerdynamics.com
81
HGN-375(A, B, C) Series Example & Ordering Code
01
5 - 1
Q - 1
SCHEMATICS
A
1
FLANGE MOUNT, TOP/BOTTOM
SNAP-IN
LINE
FLANGE MOUNT, SIDES
L mH
FUSE
L
CASE CODE:
=A
=B
=C
R
N
L'
Cy
CX
L
G'
Cy
LOAD
HGN-375 A
N'
FUSE
L mH
G
Lg
2
R
N
=Q
6.6
SOLDER
=S
WIRE
=W
G'
Cy
N'
L mH
LINE
=2
RED ILLUMINATED SWITCH, 1 FUSE (5X20MM)
=3
RED ILLUMINATED SWITCH, 2 FUSE (5X20MM)
=4
GREEN ILLUMINATED SWITCH, 1 FUSE (5X20MM)
=5
GREEN ILLUMINATED SWITCH, 2 FUSE (5X20MM)
=6
R
CX
L'
L
FUSE
L mH
G
N'
G'
Lg
2M
L
N
G
NO BLEEDER RESISTOR & NO GROUND CHOKE
=
BLEEDER RESISTOR (1/4 W, 1M)
=
BLEEDER RESISTOR (1/2 W, 1M)
=
BLEEDER RESISTOR (1/4 W, 1M) & GROUND CHOKE =
BLEEDER RESISTOR (1/2 W, 1M) & GROUND CHOKE =
GROUND CHOKE (400µH)
=
L mH
FUSE
LINE
BLACK, NON-ILLUMINATED SWITCH, 2 FUSE (5X20MM)
L mH
FUSE
N
FUSE
& SWITCH BLACK, NON-ILLUMINATED SWITCH, 1 FUSE (5X20MM) = 1
OPTIONS:
OPTIONS:
COMPONENT LOCATIONS:
L'
Cy
1M
L
OPTIONS:
CX
LOAD
QUICK CONNECT
UL 1015, 18AWG
STRANDED, 4”
FUSE
L
MEDICAL
SCHEMATICS
8.0
2.0 -3.0L
4.0/0.187
CX
G
3.0 -3.6L
6.3/0.25
L mH
FUSE
L
LOAD
01
02
03
04
06
10**
R
FUSE
CX
L
L'
CX
L mH
LOAD
TERMINAL:
=
=
=
=
=
=
LINE
CURRENT RATING (A):
N'
G'
0
5
6
7✠
8✠
9✠
STANDARD TYPE
STANDARD TYPE; ADDITIONAL C(X) BEHIND L
WITHOUT C(Y); C(X) ONLY
WITHOUT C(Y); ADDITIONAL C(X) BEHIND L
=
=
=
=
1
2✢
1M
2M✢
✢
Contact PDI for attenuation numbers
**UL and cUL approved to 10A; VDE approved
to 6.3A
✠
Not available for Schematic 2 & 2M
ATTENUATION CODE TABLE:
Non-Medical applications, select Attenuation code with corresponding component values from the table.
Capacitor C(x) Capacitor C(y) 1A (mH)
0.1µF
2200pF
6.5
0.1µF
3300pF
3.7
0.22µF
2200pF
7.5
0.22µF
3300pF
10.5
2A (mH)
3.8
2.7
5.5
6.5
3A (mH)
2.5
1.8
2.5
2.5
4A (mH)
1.6
1.3
2.0
2.7
6A (mH)
0.8
0.8
0.8
1.05
10A (mH)
0.2
0.3
0.4
0.4
=
=
=
=
A
B
C
D
=
=
=
=
M1
M2
M3
M4
Medical applications, select Attenuation code with corresponding component values from the table.
Capacitor C(x)
0.1µF
0.1µF
0.22µF
0.22µF
82
1A (mH)
6.5
3.7
7.5
10.5
2A (mH)
3.8
2.7
5.5
6.5
3A (mH)
2.5
1.8
2.5
2.5
4A (mH)
1.6
1.3
2.0
2.7
6A (mH)
0.8
0.8
0.8
1.05
10A (mH)
0.2
0.3
0.4
0.4
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com • www.powerdynamics.com
HGN-375(A, B, C) Series Attenuation Tables
Non-Medical Applications
Medical Applications
❖
Insertion loss in dB (50 Ohm circuit)
Attenuation Current
Code
Rating
1A
2A
3A
4A
6A
10A
B
C
D
Insertion loss in dB (50 Ohm circuit)
Comm. Mode(L-G) in MHz Diff. mode(L-L) in MHz
.15 .5 1 5 10 30 .15 .5 1 5 10 30
34 38 40 32 26 11
8
25 37
71 62 12
29 32 55 48 49 51
8 23 34
68 64 14
28 36 39 45 48 39
8 19 27
58 65 15
22 27 30 48 54 47
8 19 28
66 72 34
18 24 28 44 50 47
8 18 26
43 51 31
8 14 18 33 41 39
8 18 25
29 38 31
1A
2A
3A
4A
6A
10A
29 33 47 53 57 41
8 23 35
73 58 14
28 37 44 52 56 41
8 19 27
74 59 17
25 33 46 53 57 44
8 19 29
63 62 13
19 24 27 43 53 38
8 18 25
57 60 32
19 29 36 49 55 46
8 18 23
50 54 24
11 19 24 41 53 36
8 18 24
51 46 25
1A
2A
3A
4A
6A
10A
37 44 52 47 48 49
17 35 48
65 57 36
31 34 48 50 52 50
16 33 48
63 62 17
25 30 34 45 47 39
15 27 37
59 57 21
27 28 33 50 56 48
14 26 35
51 57 24
19 25 30 43 51 44
15 25 32
60 59 29
14 19 24 41 54 42
14 25 33
45 56 31
1A
2A
3A
4A
6A
10A
36 54 53 45 32 40
26 60 84
49 36 17
35 42 50 51 57 59
15 32 45
70 71 14
25 31 37 48 52 37
15 27 37
60 56 23
26 32 41 49 51 45
14 26 36
64 57 23
19 27 32 47 56 45
14 25 31
56 59 31
14 18 22 38 49 41
17 42 64
58 49 29
A
✧
Attenuation Current Comm. Mode(L-G) in MHz Diff. mode(L-L) in MHz
Code
Rating
.15 .5 1 5 10 30 .15 .5 1 5 10 30
1A
35 38 40 32 20 24
8 25 37 71 62 12
2A
30 34 36 31 18 22
8 23 34 68 64 14
3A
27 34 36 29 23 22
8 19 27 58 65 15
4A
22 27 28 29 26 13
8 18 26 43 51 31
6A
20 25 26 27 25 32
8 18 25 29 38 31
10A
9 13 19 19 17 13
7 17 23 39 47 27
M1
M2
M3
M4
1A
2A
3A
4A
10A
28 35 37 28 22 24
8 20 29
61 48 15
25 33 58 51 56 41
8 20 30
57 47 13
11 16 18 18 16 12
8 18 24
47 36 24
19 23 24 27 27 21
8 19 27
47 45 30
11 16 18 18 16 12
8 18 24
47 36 24
1A
2A
3A
4A
6A
10A
37 45 41 22 30 19
17 35 47
57 44 34
31 35 37 31 37 15
16 34 48
57 54 18
25 29 30 26 19 12
15 28 38
52 47 19
24 27 28 30 27 22
14 26 37
44 45 23
19 24 25 25 23 17
15 26 33
50 44 27
14 16 18 20 20 15
14 26 34
37 35 26
1A
2A
4A
6A
17 36 49 65 47 23
38 42 42
25 43 16
35 38 40 33 20 24
16 33 45
66 53 14
26 30 31 27 19 14
14 27 37
60 46 20
19 24 25 25 24 17
14 25 33
45 42 29
✧
This table applies to schematic 1M only.
Visit our website or contact PDI for other schematic attenuation numbers.
❖
This table applies to schematic 1 only.
Visit our website or contact PDI for other schematic attenuation numbers.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com • www.powerdynamics.com
83