ARTESYN LX200-4617

LX200 SERIES
Flexible single and muliple outputs
•
•
•
•
•
•
•
The LX200 series offers 200 Watts of continuous output power in a low profile
industry standard footprint. With two single output options and a flexible
multiple output version, the series can address most power requirements as
standard. The design is specifically tailored to allow full flexibility and
modifications to meet customer applications can be implemented with relative
ease. The LX200 AC input series meets the safety requirements of EN60950,
VDE0805, UL1950 and CSA C22.2 No. 950. Input conducted noise levels meet
the requirements of FCC and EN55022 class B. LX200 series power supplies
are ideal for use in applications such as point-of-sale equipment, central and
public telecom power systems and network equipment.
[ 2 YEAR WARRANTY ]
SPECIFICATION
200W continuous, 300W peak output power
Industry standard footprint, low profile
Conducted noise to meet EN55022 class B
AC and DC input voltage options in same package
Efficiency up to 88%
Optional power sharing/VME signals board
Autoranging input option
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Voltage adjustability
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
Vout on singles
+5V output on multiple
-8%/+16%
±20%
Remote sense
±10%
Line regulation
(LL to HL, FL)
Single outputs
Multiple: +5V output
Multiple: aux. outputs, Note 5
±0.2%
±0.2%
±0.5%
Load regulation
(20% to 100% FL)
Single outputs:
Multiple: +5V output
Multiple: -5V output
Multiple: ±12V, 24V, Note 5
±0.2%
±1.0%
±4.0%
±2.0%
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, level A
EN55022, level B
EN61000-4-2, level
EN61000-4-2, level
EN61000-4-5, level
EN61000-4-4, level
EN61000-4-3, level
EN61000-4-6, level
Transient response
5A load step on main output
Auxiliary outputs, Note 5
25% di/dt
±0.02%/°C
±0.04%/°C
Main/single output
Output power limit
Multiples:
300W Pout
primary power limited
Singles:
105%-120% Iout
current foldback
Hold-up time
110/230VAC
All outputs
130% ±10% Vout
Switching frequency
Fixed
Approvals and
standards
EN60950, VDE0805, UL1950
See Note 7
CSA C22.2 No. 950
Weight
3000VAC
1500VAC
25A max.
115VAC, 60Hz
230VAC, 50Hz
1.6mA
2.5mA
Logic 0 on ROF
44kHz
1.3kg (46oz)
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating
0°C to +70°C
Non-operating
–25°C to +85°C
0°C to +40°C ambient,
200W
convection cooled
40°C to 70°C ambient, Derate linearly
convection cooled
to 25% full load
Peak (0°C to 40°C, max. 10s)
300W
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration
Operating, 5–50Hz
0.05mm pk-pk
Operating, 50–100Hz 0.025mm pk-pk
Non-operating
100mm drop on
chassis face
50Hz/60Hz
Input surge current
PAGE 1
82% min.
Input/output
Input/chassis
Yes
LX200-46xx models, 175 to 264VAC
(230VAC version)
LX200-76xx models,
98 to 132VAC
autorange version
190 to 264VAC
Drop-out voltage
90VAC
Input frequency
Remote OFF
28ms
Isolation voltage
INPUT SPECIFICATIONS
Safety ground
leakage current
1
1
1
1
2
2
1.0%
Overvoltage protection
Input voltage range
See Note 3
criteria
criteria
criteria
criteria
criteria
criteria
1% max. dev., 1ms recov.
Temperature coefficient Main/single output
Multiple: auxiliary outputs
Short circuit protection
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
GENERAL SPECIFICATIONS
Efficiency
Cross regulation
3
4
3
3
3
3
5% to 95% RH
10,000 feet max.
30,000 feet max.
AC/DC POWER SUPPLIES
|
200W AC
200 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENTS
OUTPUT
VOLTAGE
MAX
(1)
PEAK
RIPPLE
(2)
MODEL NUMBER
RMS
PK-PK
(3)
230VAC
AUTORANGE
LX200-4620
LX200-7620
+5.0V
20.0A
40.0A
0.2%
2.0%
–5.0V
4.0A
10.0A
0.2%
2.0%
–12.0V
4.0A
10.0A
0.2%
2.0%
+12.0V
8.0A
20.0A
0.2%
2.0%
+24.0V
4.0A
10.0A
0.2%
2.0%
(4)
9.0A
–
0.1%
1.0%
LX200-4624
LX200-7624
(4)
4.5A
–
0.1%
1.0%
LX200-4617
LX200-7617
24.0V
48.0V
Notes
PIN CONNECTIONS
PIN NO
INPUT
1
Earth
1
MULTI O/P SINGLE O/P
PS
SIGNALS
PS
SRS
2
N/C
ACF
ACF
ACF
3
Neutral
SRS
SRS
DCF
2
3
4
N/C
ROF
ROF
PM
5
Live
+5VS
0VS
PS
6
N/C
+5V
0V
ROF
7
115V
+5V
0V
+VS
8
Link
+5V
0V
0V
9
N/C
0V
0V
–
10
N/C
0V
0V
–
11
N/C
0V
+Vout
–
12
N/C
–5V
+Vout
–
•
13
N/C
–12V
+Vout
–
•
14
N/C
+12V
+Vout
–
15
N/C
+24V
+VS
–
4
5
6
7
The multiple output LX200 has a continuous output power rating of 200W.
The single-output versions have a continuous output power rating of
216W.
Peak power figures for individual outputs on the multiple output unit are
for less than 10 seconds duration. The overall peak power for the unit is
300W for 10 seconds duration.
The LX200 is available with a standard 230VAC input operation (order
LX200-46xx) or the input board can be fitted with an autorange circuit
which automatically senses the input voltage and switches to the
appropriate voltage range (order LX200-76xx).
Single output models are adjustable -8%, +16%.
A 10% load on the main output is necessary to maintain regulation on the
auxiliaries at full load (multiple output model).
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Consideration should be given to measuring the temperature on the main
transformer (T1) when the power supply is installed in end-use equipment.
The measured temperature on T1 must not exceed 90°C. For further
information on the LX200 safety approvals, contact Computer Products.
Options
DC input models for 24V and 48V operation are detailed on the LX200,
LX350 and LX550 series DC/DC converter data sheet on page 170.
A cover and signals board are available as options. To order, add the
suffixes ‘-C’, ‘-S’ respectively, see table below.
OPTIONS
OVERLOAD/SHORT CIRCUIT PROTECTION
The overload/short circuit protection mechanisms are different for the single
output models and the multiple output model.
The single output models will current limit when the output load reaches
105-120% of maximum load during overload or short circuit conditions.
The unit will operate in a constant current mode making the single output
models suitable for battery charging applications.
The multiple output model uses a power limiting function. When the total
output power reaches 300W the outputs will foldback to the values detailed
below:
Output
+5V
+12V
+24V
–5V/–12V
Foldback Value
15A continuous
4A continuous
2A continuous
Protected by 4A Multi Fuse™
The outputs will not foldback until the total output power exceeds the maximum power limits. This allows the units to have a peak power capability
but it requires that care must be taken not to permanently overload any
individual output. The +5V, +12V and +24V outputs are not individually protected and it is recommended that the maximum continuous load does not
exceed the value given in the output specifications. The -5V and -12V outputs are individually protected by a 4A Multi Fuse™ and the maximum continuous load should not exceed the value given in the output specifications.
http://www.artesyn.com
None
Cover
Signals
Cover and Signals
SUFFIX
-C
-S
-C-S
EXAMPLE
LX200-76xx
LX200-76xx-C
LX200-76xx-S
LX200-76xx-C-S
SIGNALS (OPTIONAL)
An optional signals board supplies the following VME utility bus signals:
ACF (AC Fail) Logic 1 to 0 transition occurs >10ms before outputs fall
below 80%-85% of nominal in the event of input failure.
DCF (DC Fail) Logic 0 occurs if output falls below 85%–95% of nominal.
SRS (System Reset) Logic 1 for system OK (AC and DC good and reset
times [200ms])
PM Power Monitor signal, proportional to the output power, ratio of
20mV/W ±10%.
PS Power Share connections, to be joined for parallel operation of two
or more units, ensuring equal power share. For power share
operation unit outputs need to be set to ±5% of each other and
should be connected in star configurations with the load as star
centre.
PAGE 2
AC/DC POWER SUPPLIES
|
200W AC
200 Watt
AC/DC universal input switch mode power supplies
Mechanical notes
A Input and output connectors are 15 way terminal block, 5mm pitch.
Signals board option is 8 way, single row right angle 0.1”, Molex
910210128, this mates with 90147 1108 or equivalent.
B Customer fixing screws (A) are M3 isometric. They must not penetrate into
unit by more than 5mm.
INPUT
1
SYSTEM
O. K. LED
SIGNALS
1
8
1
15
OUTPUT
15
9.18 (233.2)
A
A
A
A
A
2.06
(52.4)
1.25
(31.75)
6.27 (159.3)
1.25
(31.75)
A
7.15 (181.6)
A
A
A
(15)
A
(21)
8.52 (216.4)
0.59 0.83
2.05
(52)
1.02
(25.9)
.42
(10.7)
ALL DIMENSIONS IN INCHES (mm)
DERATING CURVE (See Notes 1 & 2)
Output Power (Watts)
300W
PEAK OUTPUT
POWER
International Safety Standard Approvals
Multiple output and 24V Single output units are approved to these
200W
standards. Safety approval pending for 48V output model. See Note 7
NATURAL
CONVECTION
COOLING
EN60950/VDE0805 Reg. File No. 90371
UL1950 File No. E136005
50W
CSA C22.2 No. 950 File No. LR41062C/LR101320
0W
10% MIN. LOAD FOR AUXILIARY REGULATION
0°C 10°C
PAGE 3
20°C
30°C
40°C
50°C
60°C
70°C
http://www.artesyn.com
PAGE 4
DS_LX200AC_19980401.PDF
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising