LAMBDA MF1210

MF-SERIES
䡵 Features
(1) Wide band: High attenuation.
Band wide: 150kHz ~ 30MHz, 2 stage filter
(2) Fast-on Terminals
(3) Compact, thin type package
Low profile metal case
10A type: 26mm
䡵 Safety standard
UL1283,
CSA Std. C22. 2 No. 8 (C-UL)
VDE0565 Teil. 3
5653
EN133200
EN133200
(VDE0565 will expire on July 23, 2003.)
MF1216
MF1210
MF1206
䡵 Specifications
Item
Model
MF1206
(Note)
6A
MF1210
1
Rated voltage (AC, DC)
2
Rated current (AC, DC)
3
Test voltage (terminal to case, AC 1 minute)
2500V (20mA) at 25°C, 70% RH
4
Isolation resistance (terminal to case, 500VDC)
100MΩ min. at 25°C, 70% RH
5
Leakage current
250V
10A
Noise Filter
DC resistance
7
Temperature rise
8
Operating temperature
9
Operating humidity
10
Storage temperature
11
Storage humidity
12
Vibration
13
Safety standard
14
Weight
16A
0.5mA max.
125V, 60Hz
1mA max.
250V, 60Hz
6
MF1216
140mΩ max.
50mΩ max.
34mΩ max.
40°C max.
–25 ~ +85°C
30% ~ 95% RH (No dewdrop)
–40 ~ +85°C
10% ~ 95% RH (No dewdrop)
Sweep: 10 ~ 55 ~ 10 Hz (for one minute), Amplitude: 1,5 mm
X, Y and Z axes for 2 hours
Approved by UL1283, CSA C22.2 No. 8 (C-UL), VDE0565 Teil 3 and EN133200 (VDE).
(typ)
190g
220g
310g
(Note) : Value at Ta <
= 35°C. Refer to the derating curve shown below at Ta > 35°C.
䡵 Circuit
䡵 Derating
䢇 Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
䢇 Contact us about delivery before ordering.
156
MF-SERIES
䡵 MF1206
Case: Metal
(Unit: mm)
䡵 MF1210
Noise Filter
Case: Metal
(Unit: mm)
䡵 MF1216
Case: Metal
(Unit: mm)
157
MF-SERIES
CHARACTERISTICS
䡵 Typical Insertion Loss
(2) Symmetrical
(1) Asymmetrical
Attenuation (dB)
MF1206
Attenuation (dB)
MF1206
Frequency (MHz)
Frequency (MHz)
Frequency (MHz)
MF1216
Attenuation (dB)
MF1216
Attenuation (dB)
Noise Filter
Attenuation (dB)
MF1210
Attenuation (dB)
MF1210
Frequency (MHz)
Frequency (MHz)
158
Frequency (MHz)