N1500 and N2000 SERIES Single, and dual output • • • • • • • • The N1500 and N2000 series are a range of system-orientated, single or dual output power supplies with output powers of 1500W and 2000W. Harmonically corrected, they operate from 180VAC to 264VAC. World wide safety approvals are standard. Fan cooled and enclosed in the industry standard 5 x 8 x 11 inch form, the N1500 and N2000 series are an ideal choice when the economy and predictable performance of a centralized system power supply are desired. By utilizing dual high current converters, operating independently or together, a wide variety of output voltage and current combinations can be factory configured. The N1500 and N2000 extend the range of the N1000 family. Forced current share provides higher current to satisfy needs in large systems, or to power expansion chassis. Dual output models at 5VDC/12VDC are perfect to power mass storage systems. Other applications might use 5VDC/3.3VDC, both operating at high currents. Single output versions, operating alone or in redundant mode provide an economic power source for distributed systems. System interface signals include AC and DC good, current monitor (V1). OVP, OCP, overtemperature protection, remote enable, margin check inhibit as standard. By combining robust performance and broad range, the N1500 and N2000 series sets the standard for centralized system power supplies. [ 2 YEAR WARRANTY ] SPECIFICATION OUTPUT SPECIFICATIONS Active harmonic correction to EN61000-3-2 180VAC to 264VAC input voltage range Flexible output voltage configuration Two output power ratings Forced current sharing, all outputs DC OK (including LED) UL, CSA and TÜV safety approvals Industry standard 5 x 8 x 11 inch footprint All specifications are typical at nominal input, full load at 25°C unless otherwise stated (2) EMC CHARACTERISTICS Voltage adjustability Accessible at front panel Remote sense Open/reverse sense lead protection Compensates for voltage drop of up to 0.5V to the load Regulation, line or load All outputs, NL-FL at nominal line or all line variations at FL Cross regulation ±0.2%; 10mV min. 0.2% max. or 10mV between outputs Overshoot/undershoot Transient response None at turn-on/off ≤2.0% max. dev., ≤200µs recovery to 1.0% Main output 25% step load change at 1A/µs Temperature coefficient 0Hz to 20MHz Overvoltage protection Reset by cycling AC 50mV pk-pk or 1.0% Overload protection 115 to 130% of nominal 105-115% full load All outputs Thermal protection Auto recovery EN55022/11, FCC part 15 EN55022/11, FCC part 15 EN61000-3-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 ±5.0% 50% to 100% load Current monitor (V1) 5VDC at full load ±0.5V INPUT SPECIFICATIONS Input voltage range 180 to 264VAC Input frequency range Level A Level A Conforms Level 3 Level 3 Level 3 Level 3 GENERAL SPECIFICATIONS Hold-up time 180VAC, 2kW load Efficiency 230VAC, full load Isolation voltage Input/output Input/chassis Output/output 15ms min. 73% 3000VAC 1500VAC 500VAC Switching frequency 100kHz Approvals and standards EN60950, UL1950, CSA C22.2 No. 950 Weight 6.9kg (15Ibs) Size 5 x 8 x 11 inches 127 x 203.2 x 279.4 mm Auto shutdown, AC reset Current sharing MTBF per MIL-HDBK-217E 100,000 hours ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient Non-operating Cooling 60CFM Relative humidity Non-condensing Altitude Operating Non-operating Vibration 5Hz to 500Hz 0°C to +50°C -15°C to +85°C Internal DC ball bearing fan 47Hz to 63Hz Input surge current Meets IEEE std. 587.1980; 3KV ring wave Input current 230VAC, 2000W Power factor 230VAC, 2kW load 0.98 min. Power up time Full load 1.0s max. PAGE 1 Radiated emissions Conducted emissions Harmonic distortion Electrostatic discharge RF field susceptibility Electrical fast transients/bursts Surge susceptibility ±0.02%/°C Ripple and noise Short circuit protection ±10% 0% to 95% RH 6,000 feet max. 55,000 feet max. 13A 2.4G rms peak MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES | 1500-2000W AC/DC 1500 and 2000 Watt AC/DC high wattage power supplies with PFC MAX. OUTPUT POWER (1) OUTPUT V1 OUTPUT V2 VOLTAGE/CURRENT VOLTAGE/CURRENT MODEL NUMBER 1500W 3.3V @ 300A N1500-96-9 1500W 5.0V @ 300A N1500-96-1 1500W 12V @ 125A N1500-96-2 1500W 24V @ 62A N1500-96-4 1500W 28V @ 54A N1500-96-5 1500W 48V @ 31A N1500-96-6 1500W 5.0V @ 200A 12V @ 50A N1500-96-12 1500W 5.0V @ 200A 24V @ 24A N1500-96-14 2000W 5.0V @ 360A N2000-96-1 2000W 12V @ 150A N2000-96-2 2000W 24V @ 83A N2000-96-4 2000W 28V @ 71A N2000-96-5 2000W 48V @ 42A N2000-96-6 2000W 5.0V @ 240A 12V @ 66A N2000-96-12 2000W 5.0V @ 240A 24V @ 33A N2000-96-14 2000W 5.0V @ 240A 3.3V @ 120A N2000-96-19 International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. R917062 TÜV Certificate No. R9172062 UL1950 File No. E135734 CSA C22.2 No. 950 Bulletin No. 1402C http://www.artesyn.com PAGE 2 1500-2000W AC/DC | MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES 1500 and 2000 Watt AC/DC high wattage power supplies with PFC PIN NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 OUTPUT PIN CONNECTIONS J1 J2 + Sense (V1) (4) + Sense (V2) Current Monitor (V1) (5) - Sense (V2) Inhibit (5) Current Share (V2) - Sense (V1) (4) Inhibit (5) No Connection N/A No Connection N/A Current Share (5) N/A Remote Adj. (V1) (6) N/A AC Good (5) N/A Chassis Ground N/A Logic Ground N/A Margin (7) N/A No Connection N/A DC OK (5,8) N/A Mechanical notes A AC connector is 3 position terminal block (#8 screws included), mating to #8 ring tongue terminal. B DC output is 5/16-18 studs mating to 5/16 terminal lugs. C J-1 signal connector is Molex 39-30-1140 or equivalent. Mating connector is Molex 39-01-2140 or equivalent. D J-2 signal connector is Molex 39-01-1120 or equivalent. Mating connector is 39-01-2120 or equivalent. E Signal connector contacts are Molex 39-00-0039 or equivalent. F TB1 and J2 are not installed on single output models. G Alternate I/O configurations are available. Please consult factory for further details. Notes 1 2 3 4 5 6 7 8 1500W or 2000W max. power. All outputs isolated. Specifications refer to all outputs except as noted (V1). Signal referenced to V1 output neg. sense trim. Use 20AWG or larger twisted pair. Reference to Logic Ground (Pin J1-J11). See Figure 4. See Figure 3. See Figure 5. 12.13 Max. (308.10) 11.00 (279.40) 0.75 (19.05) AC Input (# 8 Screws) 6.750 (171.450) ACH ACN 5.00 (127.0) 4.00 (101.60) + + V1 0.90 (22.86) _ V1 1.30 (33.02) J1 0.50 (12.7) 8-32 x 0.29 (7.37) Deep (4) Both Sides Main Output 5/16 - 18 Studs 50 IN-LB Torque Max. 1.13 (28.70) 2.80 (71.12) J1 5.75 (146.05) 0.90 (22.86) PIN 1 AIRFLOW 1.00 (25.40) 8.00 (203.2) 0.90 (22.86) 8-32 x 0.29 (7.37) Deep (4) Top and Bottom ALL DIMENSIONS IN INCHES (mm) PAGE 3 MEDIUM TO HIGH POWER AC/DC POWER SUPPLIES | 1500-2000W AC/DC 1500 and 2000 Watt AC/DC high wattage power supplies with PFC FIG. 1 15V FIG. 2 (Ref. FIG 5) FIG. 5 J1-P9 AC Good, J1-P14 DC OK AC Power Fail Signal/DC OK Timing 10K Low = Power/Output fail High = Power/Output OK External Pull-up Required Sink Current 20mA (On Voltage 0.7V) J1-P3 AC Input Voltage 170Vrms 0V >10ms AC Good Flag Close to Enable >5ms FIG. 3 DC Outputs FIG. 4 Open = Nominal Voltage 5V Tie to +5V for High Margin Tie to Logic Ground (J1-11) For Low Margin. Output Voltage DC Good Flag (J1-P8) > 10K (J1-P12) Margin Sense STANDARD CONTROL SIGNALS Remote enable DC OK (See Figures 2 and 5) AC power fail signal (See Figure 5) Margin Hi/Lo (V1) (See Figure 3) Remote Adjust (See Figure 4) Current Monitor See Figure 1 Signal remains "Hi" as long as output is ±5.0% of nominal. Signal "Hi" when AC >170VAC and "Lo" when <150VAC. Allows ±5.0% change in output for system margin checking. The outputs may be remotely adjusted linearly ±10%. Analog signal indicates load current in single or parallel operation. 5±0.5VDC represents FL, resistive load 103kΩ. DS_N1500/N2000_19980401.PDF http://www.artesyn.com PAGE 4