NAL40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES • • • • • • 40W AC/DC Universal Input Switch Mode Power Supplies 1 5.0 x 3.0 x 1.2 inch package (1U applications) Ideal for high volume designs Industry standard package Overvoltage and short circuit protection 40W with free air convection EN55022, EN55011 conducted emissions level A The NAL40 series are 40W universal input AC/DC power supplies on a 5 x 3 inch card with a maximum component height of 1.2 inch for use in 1U applications. These series are available with a wide range of models in the industry standard 5 x 3 inch footprint at low cost making the series ideal for new and existing high volume communication and industrial applications. The NAL40 meets level A conducted emissions. The NAL40 series provide 40W of output power with free air convection cooling with a peak output of 50W for a maximum duration of 60 seconds. The NAL40 series are designed for use in high volume low power data networking, computer and telecom applications such as hubs, routers, POS terminals, cable modems and PABX’s. This list is not exclusive as the generic feature set of both series with industry standard output configurations provide a solution for most high volume applications including many industrial applications. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25°C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Line regulation Main output Auxiliary outputs ±0.5% ±1.0% Total regulation Main output Auxiliary outputs ±3.0% ±5.0% Overshoot/undershoot At turn-on <10% Transient response +5.1V (1.5A to 3A step) Temperature coefficient ±150mV max. dev., 500µs recovery ±0.02%/°C Overvoltage protection +5.1V output Output power limit Primary power limited Short circuit protection Multiple output Single 12V, 15V, 24V and 48V 6.25V ±0.75Vout 50W Pout, min. 110W Pin, max. 30 seconds Continuous automatic recovery INPUT SPECIFICATIONS Input voltage range Universal input Input frequency range 90 to 264VAC 120 to 370VDC 47Hz to 440Hz Input surge current 110VAC, cold start 230VAC, cold start Safety ground leakage current 110VAC, 60Hz 230VAC, 50Hz 15A 32A Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Perf. Perf. Perf. Perf. Perf. Perf. level A level A criteria 2 criteria 2 criteria 2 criteria 2 criteria 2 criteria 2 GENERAL SPECIFICATIONS Hold-up time 110VAC 230VAC 10ms @ 40W 60ms @ 40W Efficiency Isolation voltage 68% min. @ 40W Input/output Input/chassis Switching frequency Approvals and standards (See Note 9) Variable VDE0805, EN60950, IEC950 BABT, IEC1010, UL1950 CSA C22.2 No. 950 Weight MTBF 3000VAC 1500VAC 200g (7.06oz) MIL-HDBK-217F 150,000 Hours ENVIRONMENTAL SPECIFICATIONS Thermal performance 0.2mA 0.4mA Operating 0°C to +70°C Non-operating -40°C to +85°C 0°C to 50°C ambient, 40W convection cooled 50°C to 70°C, Derate linearly ambient conv. cooled to half load Peak (0°C to 50°C) max. 60s 50W Relative humidity Non-condensing Altitude Operating Non operating 5% to 95% RH Vibration Three orthogonal axes, 2.4G rms random vibration, 10 5Hz to 500Hz minute test for each axis 10,000 feet max. 30,000 feet max. File Name: NAL40.PDF Rev: 19 Nov 2001 NAL40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT CURRENT OUTPUT VOLTAGE MAX + 5.1V (IA) 3A (1) PEAK 7A (2) FAN (3) 4A TOTAL (4) RIPPLE REG. 50mV MODEL NUMBER (5) ±3.0% +12V (IB) 2A 3A 2A 120mV ±5.0% –12V (IC) 0.35A 1A 0.5A 120mV ±5.0% +5.1V 3A 7A 4A 45mV ±3.0% +12V 0.35A 3A 0.5A 110mV ±5.0% NAL40-7608 (5) NAL40-7628 (8) NAL40-7607 (5) NAL40-7610 (5) NAL40-7629 (5) –12V 0.35A 1A 0.5A 110mV ±5.0% +5.1V (IA) 3A 7A 4A 50mV ±3.0% +12V (IB) 2A 3A 2A 120mV ±5.0% –5V (IC) 0.35A 1.0A 0.5A 50mV ±5.0% +5.1V (IA) 3A 7A 4A 50mV ±3.0% +15V (IB) 1.5A 3A 1.5A 160mV +13% –0% –15V (IC) 0.35A 1A 0.5A 150mV ±5.0% +5.1V (IA) 3A 7A 4A 50mV ±3.0% +12V (IB) 2A 3A 2A 120mV ±5.0% 5V 6A 10A 8A 50mV ±3.0% NAL40-7605 12V 3.3A 5A 4A 120mV ±3.0% NAL40-7612 15V 2.6A 4A 3.3A 150mV ±3.0% NAL40-7615 24V 1.6A 2.5A 2A 240mV ±3.0% NAL40-7624 48V 0.8A 1A 1A 480mV ±3.0% NAL40-7617 (B) Notes 1 2 3 4 5 6 7 8 9 Natural convection cooling (40W maximum). Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. Forced air, 20CFM at 1 atmosphere, 50W maximum. Figure is peak-to-peak. Output noise measurements are made across a 50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF capacitor. Total regulation is defined as the static output regulation at 25°C, including initial tolerance, line voltage within stated limits, load currents within stated limits and output voltages adjusted to their factory settings. For multiple output units to maintain stated regulation then: 0.25 ≤ IA / IB ≤ 5, for IB > 0.3A 0.50 ≤ IA / IB ≤ 5, for IB < 0.3A Minimum load must also be 4W to achieve design MTBF. For maximum output current IC on triple-output models, i.e. for: IC = IMax., then IA min. ≥ 0.5A and IB ≥ IC. This does not apply to the NAL40-7628 which has a separately regulated output, see note 8. Derating curve is application specific for ambient temperatures >50°C, for optimum reliability, no part of the heatsink should exceed 120°C, and no semiconductor case temperature should exceed 130°C. Caution: allow a minimum of 1 second after disconnecting line power when making thermal measurements. The NAL40-7628 has separately linear regulated +12V and -12V outputs. The loading conditions in note 5 do not apply. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. DERATING CURVE (See Notes 6, 7) Output Power (Watts) 50W 20 CFM FORCED AIR COOLING 40W 25W NATURAL CONVECTION COOLING 4W 20W 4W MIN. LOAD TO ACHIEVE DESIGN MTBF 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C Available Output Power V's Ambient Temperature www.artesyn.com File Name: NAL40.PDF Rev: 19 Nov 2001 NAL40 Series Single, dual and triple output LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm Mechanical Notes A Ground pad encircling mounting hole near P1 allows system grounding through a metal stand-off of up to 8mm max. diameter to metal chassis. B A standard L-bracket and cover is available for mounting, which contains all screws, connectors and necessary mounting hardware. Order part number ‘NAL40 COVER KIT’. AC (J1) mating connector Molex 09-50-3031 or equiv. with Molex 08-50-0105 or equiv. crimp terminals. DC (J2) mating connector Molex 09-50-3061 or equiv. with Molex 08-50-0164 or equiv. crimp terminals. 5.00 (127.00) 0.156 (3.96) Dia. (4 Places) J2 F1 F3.15A, 250VAC 1 3.00 (76.20) 2.55 (64.80) T1 1 J1 P1 0.22 (5.59) 4.55 (115.80) 0.22 (5.59) MAXIMUM COMPONENT HEIGHT 1.2 inches ALL DIMENSIONS IN INCHES (mm) International Safety Standard Approvals VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1076 Licence No. 70567, 1076 and 90354 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C Certificate No. PS/605108 INPUT PIN CONNECTIONS J1 Pin 1 AC Neutral Pin 2 No Pin Pin 3 AC Line P1 Pin 1 Safety Ground OUTPUT PIN J2 SINGLE P1 +Vout P2 +Vout P3 +Vout P4 Return P5 Return P6 Return CONNECTIONS DUAL TRIPLE +12V V (B) +5.1V V (A) +5.1V V (A) Return Return Return Return N/C V (C) Data Sheet © Artesyn Technologies® 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. www.artesyn.com File Name: NAL40.PDF Rev: 19 Nov 2001