EMERSON-NETWORKPOWER NLP110

Embedded Power for
Business-Critical Continuity
Rev. 02.10.09_152
NLP110 Series
of 4
NLP110 Series
Single and
Triple Output
Total Power:
Input Voltage:
# of Outputs:
80-110 Watts
90-264 VAC
Single, Triple
Special Features
•
•
•
•
•
•
•
•
•
•
Provides low voltage outputs
Compliance to EN61000-3-2
(Power Factor = 0.98)
90 Vac to 264 Vac universal
input range
UL, CSA and VDE safety
approvals and CE-Marked to
LVD
Overvoltage and short circuit
protection
VDE0871-B, EN55022-B,
EN55011-B conducted noise
VDE0871-A, EN55022-A,
EN55011-A radiated noise
Meets all applicable and
relevant immunity standards
EN61000-4-2,4,5 and 6
RoHS compliant
2 year warranty
Electrical Specifications
Input
Input ra­nge:
Frequency:
Input surge current:
(cold start)
Safety ground
leakage current:
Input current:
Universal input
(See Note 6)
120 Vac
230 Vac
120 Vac, 60 Hz
230 Vac, 50 Hz
120 Vac @ 80 W
120 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 110 W
UL/IEC127
47-63 Hz
18 A max.
35 A max.
0.45 mA
0.75 mA
0.9 A rms
1.3 A rms
0.48 A rms
0.7 A rms
F3.15A H, 250 Vac
Total regulation:
(line and load)
Rise time:
Main output
Auxiliary outputs
At turn-on
±2.0%
±5.0%
1.0 s, max.
Transient response:
Main output
75% to 100%
step at 0.1 A µs
5.0% or 250 mV
max. dev., 1 ms max.
recovery to 1%
Input fuse:
Output
Temperature coefficient:
Safety
90-264 Vac
±0.02%/°C
Overvoltage protection:
Main outputs
125%, ±10%
• VDE0805/EN60950/IEC950
File No. 10401-3336-1096
Short circuit protection:
Cyclic operation
Continuous
Minimum output current:
Single and multiple
See table
• UL1950 File No. E136005
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
• CSA C22.2 No. 950
File No. LR41062
• CCC Mark
Embedded Power for
Business-Critical Continuity
Rev. 02.10.09_152
NLP110 Series
of 4
EMC Characteristics
Conducted emissions:
EN55022, FCC part 15
Level B
EN55022, FCC part 15
Harmonic current emission correction: EN61000-3-2
ESD air:
EN61000-4-2
Level A
ESD contact:
EN61000-4-2
Level 3
Surge:
EN61000-4-5
Level 3
Fast transients:
EN61000-4-4
Level 3
Radiated immunity:
EN61000-4-3
Level 3
Conducted immunity:
EN61000-4-6
Level 3
Hold-up time:
120 Vac, 60 Hz
16.7 ms @ 110 W
Efficiency:
120 Vac. 80 W (-9905J)
75% min.
Isolation voltage:
Input/output
Input/chassis
3000 Vac
1500 Vac
Approvals and standards pending:
EN60950, VDE0805, IEC950, UL1950, CSA C22.2 No. 950
Radiated emissions:
Compliant
Level 3
General Specifications
Weight:
283 g (10 oz)
MTBF demonstrated:
MIL-HDBK-217F
220,000 hours min.
Environmental Specifications
Thermal performance:
Operating, ambient
(see derating curve)
Non-operating
0° C to +50 °C
50 °C to 70 °C ambient convection cooled
0 °C to +50 °C, ambient convection cooled
Derate to 50% load
80 W
-40 °C to +85 °C
0 °C to +50 °C, ambient, 150 LFM forced air 110 W
Peak (0 °C to +50 °C, 60 s)
(See Note 3)
Relative humidity:
Non-condensing
5% to 95% RH
Altitude:
Operating
10,000 feet max.
Non-operating
30,000 feet max.
Vibration (See Note 5):
5-500 Hz
2.4 G rms peak
Shock
per MIL-STD-810E
516.4 Part IV
DERATING CURVE
Output Power (Watts)
110W
80W
150 LFM FORCED
AIR COOLING
NATURAL
CONVECTION
COOLING
0C
55W
40W
10C 20C 30C 40C 50C 60C 70C
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
Min (6)
Max (1)
150 LFM (2)
300 LFM (3)
Peak (4)
Ripple (5)
Total
Regulation
Model Numbers (7, 14, 15)
+5 V
0.5 A
15 A
22 A
22 A
22 A
50 mV
± 2.0%
NLP110-9605J
+12 V
0.3 A
6.4 A
9.2 A
9.2 A
11.5 A
120 mV
± 2.0%
NLP110-9612J
+48 V
0A
1.6 A
2.3 A
2.3 A
2.5 A
240 mV
± 2.0%
NLP110-9617J
+24 V
0.2 A
3.2 A
4.6 A
4.6 A
6.0 A
240 mV
± 2.0%
NLP110-9624J
+5 V (A)
0.5 A
13 A
16 A
18 A
18 A
50 mV
± 2.0%
NLP110-9693J
+3.3 V (B)
0.2 A
13 A
16 A
20 A
20 A
50 mV
± 2.0%
+12 V
0A
0.65 A
1A
1A
1A
120 mV
± 5.0%
+3.3 V (A)
0.5 A
13 A
16 A
20 A
22 A
50 mV
± 2.0%
+2.5 V (B)
0.1 A
13 A
16 A
20 A
22 A
50 mV
± 2.0%
+12 V
0A
0.65 A
1A
1A
1A
120 mV
± 5.0%
+12 V (A)
0.2 A
6.5 A
8.5 A
8.5 A
10 A
120 mV
± 2.0%
+3.3 V (B)
0.5 A
13 A
16 A
20 A
22 A
50 mV
± 2.0%
-12 V
0A
0.65 A
1A
1A
1A
120 mV
± 5.0%
+12 V (A)
0.2 A
6.5 A
8.5 A
8.5 A
10 A
120 mV
± 2.0%
+5 V (B)
0.2 A
13 A
16 A
18 A
22 A
50 mV
± 2.0%
-12 V
0A
0.65 A
1A
1A
1A
120 mV
± 5.0%
Notes
1 Free air convection.
Multiple output units: maximum continuous output power not to exceed
80 W.
For -9693J; I3.3 V = 13 A max.; I5.0 V = 13 A max.; I3.3 V + I5.0 V ² 16 A.
For -9694J; I3.3 V = 13 A max.; I2.5 V = 13 A max.; I3.3 V + I2.5 V ² 16 A
For -9695J; I3.3 V = 13 A max.; I12 V = 6.5 A max.; I3.3 V + I12 V ² 16 A.
For -9608J; I5.0 V = 13 A max.; I12 V = 6.5 A max.; I5.0 V + I12 V ² 16 A.
Single output units: maximum continuous output power not to exceed; 75 W
on -9905J; 76.8 W on -9912J,-9924J, and -9917J.
2 150 LFM forced air cooling from L4 side.
Multiple output units: maximum continuous output power not to exceed 105
W.
For -9693J; I3.3 V = 16 A max.; I5.0 V = 16 A max.; I3.3 V + I5.0 V ² 20 A.
For -9694J; I3.3 V = 16 A max.; I2.5 V = 16 A max.; I3.3 V + I2.5 V ² 20 A
For -9695J; I3.3 V = 16 A max.; I12 V = 8.5 A max.; I3.3 V + I12 V ² 20 A.
For -9608J; I5.0 V = 16 A max.; I12 V = 8.5 A max.; I5.0 V + I12 V ² 20 A.
Single output units: maximum continuous output power not to exceed 110 W
for all models.
3 300 LFM forced air cooling from L4 side.
Multiple output units: maximum continuous output power not to exceed 110
W.
For -9693J; I3.3 V = 20 A max.; I5.0 V = 18 A max.; I3.3 V + I5.0 V ² 22 A.
For -9694J; I3.3 V = 20 A max.; I2.5 V = 20 A max.; I3.3 V + I2.5 V ² 22 A
For -9695J; I3.3 V = 20 A max.; I12 V = 8.5 A max.; I3.3 V + I12 V ² 22 A.
For -9608J; I5.0 V = 20 A max.; I12 V = 8.5 A max.; I5.0 V + I12 V ² 22 A.
Single output units: maximum continuous output power not to exceed 110 W
for all models.
4 Peak output current lasting less than 30 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits.
5 Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6’ twisted pair,
terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor.
6 Minimum load required for correct start-up and operation on single outputs
and on main output of multiple versions. Failure to observe minimum
load on main output will not allow the supply to start-up correctly. Some
electronic test loads have a large delay time before they start drawing
current even though the voltage from the supply is present. During this time
delay, there is no load on the output and as a result, the supply cannot startup properly and maintain its correct output voltage. In these instances, a
dummy resistive load across the output may be necessary to load the output
of the supply until the test load can function correctly and draw the intended
minimum load. Minimum load required on auxiliary outputs to maintain
regulation.
Rev. 02.10.09_152
NLP110 Series
of 4
NLP110-9694J
NLP110-9695J
NLP110-9608J
7 For models NLP110-9608J and NLP110-9695J, the 12 V output is floating. For -12 V output, pin 11 on J2 has to be connected to Return making pin 12
the -12 V output
8 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms
5 Hz to 500 Hz.
9 For optimum reliability, no part of the heatsink should exceed 110 ˚C, and no
semiconductor case temperature should exceed 120 ˚C.
10 CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
11 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
12 The EMI specifications reference measurements made with the power supply
mounted on a grounded metal sheet extending 1 inch beyond each edge,
using an unshielded cable. No external filtering required during conducted
emissions testing but some applications may require additional filtering
to achieve system compliance. A line choke, (ac input cords looped twice
through an EMI suppression toroid) was used during radiated emissions
testing. Considerable radiated testing in 1U six-sided boxes has shown that
units can meet level B in typical systems. Application support is available
from the factory to assist with EMI compliance.
13 All models require a minimum mounting stand-off of 6.35 mm (0.25 inches)
in the end use product.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
15 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.PowerConversion.com/products.
Embedded Power for
Business-Critical Continuity
6.50
(165.10)
6.050
(153.670)
0.23
(5.842)
J4
!
1
3
12
F1
T1 (REF.)
J1
Recommended direction
for forced air relative to
power supply orientation
shown below.
4
Optimum.
Very good.
Good.
Not recommended.
2
1
J5
3.00
(76.20)
1
1
2
J3
ALL DIMENSIONS IN INCHES (mm)
MAXIMUM COMPONENT HEIGHT
IS 1.26 (32.00)
1
2
3
4
2.550
(64.770)
J2
0.23
(5.842)
2
3
Input Pin Connections
J2
Single
Triple
AC Neutral
Pin 1
No Connection
V (B)
Pin 2
No Connection
Pin 2
No Connection
V (B)
Pin 3
AC Line
Pin 3
No Connection
V (B)
Pin 4
Return
Return
Pin 1
V (A) Sense +
Pin 5
Return
Return
Pin 2
V (A) Sense -
Pin 6
Return
Return
J4
Pin 7
Return
Return
Pin 1
Pin 8
V (A)
V (A)
Pin 9
V (A)
V (A)
Safety Earth
J5
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone:+44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone:+852 2176 3333
Facsimile: +852 2176 3888
www.PowerConversion.com
Output Pin Connections
Pin 1
J3
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone:+1 760 930 4600
Facsimile: +1 760 930 0698
For global contact, visit:
1
J1
­Americas
Pin 1
V (B) Sense +
Pin 10
V (A)
V (A)
Pin 2
V (B) Sense -
Pin 11
No Connection
V (C)
Pin 12
No Connection
V (C) Return (7
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Input and output connectors
Mating connectors
Outside Plant
AC (J1) connector type
Molex 26-60-4030 or equi�������
valent.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex 08-50-0105
or equivalent crimp ����������
terminals.
DC (J2) mating connector type
Molex Spox type 26-03-3121 and contact �����������
08-52-0113.
Power Switching & Controls
Sense (J3) mating connector type
Molex 22-01-3027 and contac�������������
t 08-50-0113.
Earth (J4) mating connector ty��
pe
Molex 90028.
Sense (J5) mating connector type
Leoco 2420S020000 and co������������������
ntact 2453TPB00V1.
Surge Protection
DC (J2) connector type
12 position Molex Spox type 26-48
1125 or �����������
equivalent.
Sense (J3) connector type
Molex 22-23-2021 or������������
equivalent.
Earth (J4) connector type
Male 0.250 qui��������������
ck disconnect.
Sense (J5) connector type
Leo���������������
co 2421P02H000.
Rev. 02.10.09_152
NLP110 Series