Embedded Power for Business-Critical Continuity Rev.06.02.08 NLP65 Series 1 of 4 NLP65 Series Single, dual, and triple output Total Power: 65 - 75W Input Voltage: 85 - 264 Vac 120 - 370 Vdc* # of Outputs: Single, dual, triple Electrical Specifications Special Features • • • • • • • • • • • Universal Input 3" x 5" footprint Low profile fits 1U applications EN61000-3-2 compliance option (HCC) Overvoltage and short circuit protection 65 W with free air convection cooling EN55022, EN55011 conducted emissions level B EN61000-4-2,-3,-4, -5, -6 immunity compliant RoHS compliant LPX80 enclosure kit available 2 year warranty Safety VDE0805/EN60950/IEC950 File No. 1040100-3336-0096 Licence No. 114404 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C China Compulsory Certification 60950 *NLP65-76xx version only Input Input voltage range Universal input, (See Note 2) NLP65-76xx version only Input frequency range 85-264 Vac 120-370 Vdc 47-63 Hz Input current (cold start) 120 Vac 230 Vac 17 A max. 32 A max. Safety ground leakage current 120 Vac, 60 Hz 230 Vac, 50 Hz 0.7 mA 1.4 mA Input current 120 Vac, with PFC 230 Vac, with PFC 120 Vac, without PFC 230 Vac, without PFC 1.05 A rms 0.51 A rms 1.40 A rms 0.80 A rms Input fuse UL/IEC127 S3.15 A, 250 Vac In live and neutral Total regulation (line and load) Rise time Main output Auxiliary outputs At turn-on ±2.0% ±5.0% 1.0 s, max Transient response Main output 25% step at 0.1 A/μs 5.0% or 250 mV max. dev., 1ms max. recovery to 1% Output Temperature coefficient ±0.02%/°C Overvoltage protection Main outputs 125%, ±10% Short circuit protection Minimum output current Cyclic operation Single and multiple Continuous (See Note 6) Embedded Power for Business-Critical Continuity All specifications are typical at nominal input, full load at 25° C unless otherwise stated. Rev.06.02.08 NLP65 Series 2 of 4 EMC Charateristics (11, 12) Conducted emissions EN55022, FCC part 15 Level B Radiated emissions EN55022, FCC part 15 Level A ESD air EN61000-4-2, level 3 Perf. criteria 1 ESD contact EN61000-4-2, level 4 Perf. criteria 1 Surge EN61000-4-2, level 3 Perf. criteria 1 Fast transients Radiated immunity EN61000-4-4, level 3 EN61000-4-3, level 3 Perf. criteria 1 Perf. criteria 2 Conducted immunity EN61000-4-6, level 3 Perf. criteria 2 Hold-up time 120 Vac, 60 Hz 230 Vac, 50 Hz 16 ms @ 65 W 78 ms @ 65 W Efficiency 120 Vac, 65 W 72% typical Isolation voltage Input/output Input/chassis 3000 Vac 1500 Vac Switching frequency Fixed 100 kHz, ±5 kHz General Specifications Approvals and standards EN60950, VDE0805 (see Notes 9, 13) IEC950, UL1950, CCC60950 CSA C22.2 No. 950 Weight 283 g (10 oz) MTBF demonstrated MIL-HDBK-217F 150,000 hours min Environmental Specifications Thermal performance (see Notes 1, 3, 10) Operating ambient, 0 °C to +70 °C (See derating curve) Non-operating -40 °C to +85 °C 50 °C to 70 °C ambient, Derate to convection cooled 50% load 0 °C to 50 °C, ambient, 65 W convection cooled 0 °C to 50 °C ambient, 75 W 20 CFM forced air (See Note 10) Peak (0 °C to +50 °C, 60 s) See table Relative humidity Non-condensing 5% to 95% RH Altitude Operating Non-operating 10,000 feet max 30,000 feet max Vibration (see Note 5) 5-500 Hz 2.4 G rms peak Shock per MIL-STD-810E 516.4 Part IV DERATING CURVE Output Power (Watts) 75W 20 CFM FORCED AIR COOLING 65W NATURAL CONVECTION COOLING 0°C 38W 32W 10°C 20°C 30°C 40°C 50°C 60°C 70°C Embedded Power for Business-Critical Continuity Output Voltage Output Current Total Non-harmonic Regulation (6) Corrected Harmonic Corrected Ground Pin (12, 14, 17) NLP65-7608J NLP65-9608J NLP65-X608GJ NLP65-7610J NLP65-9610J NLP65-X610GJ NLP65-7620J NLP65-9620J NLP65-X620GJ NLP65-7629J NLP65-9629J NLP65-X629GJ Max (1) Peak (3) Fan (10) +5 V (IA) 7.5 A 9.1 A 8A 50 mV ±2.0% +12 V (IB) 2.5 A 3.3 A 3A 150 mV ±5.0% –12 V 0.65 A 0.81 A 0.8 A 120 mV ±5.0% +5 V (IA) 7.5 A 9.1 A 8A 50 mV ±2.0% +15 V (IB) 2.2 A 2.9 A 2.5 A 150 mV ±5.0% –15 V 0.65 A 0.85 A 0.8 A 150 mV ±5.0% +5 V 7.0 A 9.1 A 8.0 A 50 mV ±2.0% +24 V 1.5 A 2.6 A 2.0 A 240 mV ±5.0% +12 V 0.7 A 1.0 A 1.0 A 120 mV ±5.0% +5 V (IA) 7A 9.1 A 8A 50 mV ±2.0% +24 V (IB) 2A 2.6 A 2A 240 mV ±5.0% +5 V (IA) 7A 9.1 A 8A 50 mV ±2.0% +12 V (IB) 2.5 A 3.3 A 3A 150 mV ±5.0% +5 V 10 A 13 A 12 A 50 mV ±2.0% NLP65-7605J NLP65-9605J NLP65-X605GJ +12 V 5.4 A 7A 6.5 A 120 mV ±2.0% NLP65-7612J NLP65-9612J NLP65-X612GJ +15 V 4.4 A 5.7 A 5.3 A 150 mV ±2.0% NLP65-7615J NLP65-9615J NLP65-X615GJ +24 V 2.7 A 3.5 A 3.5 A 240 mV ±2.0% NLP65-7624J NLP65-9624J NLP65-X624GJ Ripple (4) NLP65-3322J Notes 1 Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65-X610J must not exceed 62.5 Watts continuous output power with natural convection. Model NLP65-X620J not to exceed 65 Watts continuous output power with natural convection. Model NLP65-3322J must not exceed 60 Watts continuous output power with natural convection. 2 When the input voltage is less than 90 Vac the operating temperature range is 0 °C to +40 °C. The ripple and regulation specifications may not be met. 3 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation limits. 4 Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 μF electrolytic capacitor and a 0.1 μF ceramic capacitor. 5 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 6 A minimum load on the main output is required for proper start up. For multiple outputs and single +5V output, the minimum load on the +5 V is 0.2 A. For single outputs greater than +5 V the minimum load is 0.1 A. To maintain stated regulation then: for single output units I ≥ 0.2 A for multiple output units 0.25 ≤ I(A)/I(B) ≤ 5, for I(A) ≥ 0.2 A. 7 For optimum reliability, no part of the heatsink should exceed 120 oC, and no semiconductor case temperature should exceed 130 oC. 8 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 9 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 10 Maximum continuous output power for all multiple output models must not exceed 75 Watts (70 watts for NLP65-3322J)with 20 CFM forced air cooling. Model Numbering Options 1 2 3 The enclosure version includes: IEC connector, on/off switch, wire harness output connector and fitted cover. To order, please add the suffix ‘E’ the model number, e.g. NLP65-9608EJ. See NLP65 enclosure for details. A Safety earth ground pin and ground choke are available as an option. To order, please add the suffix ‘G’ the model number, e.g. NLP65-X608GJ. To order an enclosure kit (unfitted), order the part number LPX80. 11 Conducted and radiated emissions testing were performed using the standard EN55022 set-up with a stand alone NLP65 unit placed on a grounded metal plate with a line choke on the AC input and ground wires (i.e. the wires are looped through an EMI suppression toroid). For system compliance it is usually necessary to install an ‘off-the-shelf’ AC inlet with an integral line filter in the system chassis or to install a line choke on the input wires as close as possible to AC entry point of the system chasssis. Please contact the applications group at Artesyn for assistance with EMI compliance. 12 The NLP65 units with the suffix ‘G’ is the ground pin and ground choke option. J2, L6 and JP10 are included. J2 is a safety agency approved grounding pin, L6 is a ground choke and JP10 is a jumper. This option is intended for use in nonmetallic chassis applications where grounding is not possible via the mounting screws. The ground choke is provided to assist system EMC compliance. When performing conducted emissions testing on stand alone units, the ‘G’ option is required to meet level B. To order simply add the suffix ‘G’ to the standard model number, e.g. NLP65-7608GJ, NLP65-9608GJ. This option is available for both the PFC and non-PFC versions. 13 All models require a minimum mounting stand-off of 0.25 inches (6.35 mm) in the end use product. 14 The NLP65-9608J is available with an enclosure. To order an enclosed version, see model numbering options below. 15 No PFC version, EN61000-3-2 is not applicable to this model. 16 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 17 NOTICE: Some models do not support all options. Please contact your local Emerson Network Power representative or use the on-line model number search tool at http://www.powerversion.com. Rev.06.02.08 NLP65 Series 3 of 4 Embedded Power for Business-Critical Continuity Americas Mechanical Drawing 5.00 (127.00) 4.550 (115.57) 0.225 (5.715) 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Rev.06.02.08 NLP65 Series 4 of 4 Europe (UK) J1 J3 3 N 1 L 1 3.00 (76.20) 6 2.550 (64.770) Asia (HK) T1 J2 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 C19 MAXIMUM COMPONENT HEIGHT 1.26 (32.00) Mounting Hole Diameter 0.156 (4.00) TOLERANCE: .xxx .xx 0.005" 0.02" ALL DIMENSIONS IN INCHES (mm) For global contact, visit: www.powerconversion.com technicalsupport@ powerconversion.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. INPUT PIN CONNECTIONS J1 Pin 1 AC Line Pin 2 No Pin Pin 3 AC Neutral J2 (ON ‘G’ SUFFIX ONLY) Pin 1 Safety Ground Input and output connectors Mating connectors AC (J1) connector type Molex 26-60-4030 type. AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J3) connector type Molex 26-60-4060 type. DC (J3) mating connector type Molex 09-50-3061 with Molex 2478 phosphor bronze crimp terminals or equivalent. Note: The input and output connectors are the same as those used on NFS40, NFN40, NAL40, NAN40 and NLP40. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls J3 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 OUTPUT PIN CONNECTIONS SINGLE DUAL TRIPLE V (A) V (A) V (A) Return Return Return V (B) V (A) V (A) Return Return V (C) V (B) V (A) V (A) Return Return N/C Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.