PH150S280 Specifications NEMIC-LAMBDA * PH150S PH150S ITEMS 280-3.3 280-5 1 Nominal Output Voltage V 3.3 5 2 Maximum Output Current A 30 30 3 Nominal Output Power W 99 150 72 82 4 Efficiency (Typ) (∗1) % 5 Input Voltage Range - 200 ~ 400VDC 280VDC input A 0.47 0.65 0.63 0.63 0.61 0.61 6 Input Current (Typ) 360VDC input A (at full load) 0.37 0.51 0.49 0.49 0.48 0.48 7 Output Voltage Accuracy (∗1) % ± 1% 8 Output Voltage Range (∗8) % ± 10% (At 280VDC input) 9 Maximum Ripple & Noise 100 100 150 150 240 280 (∗9) mV 10 Maximum Line Regulation 20 20 48 60 96 112 (∗2) mV 40 40 96 120 192 224 11 Maximum Load Regulation (∗3) mV 12 Over Current Protection (∗4) - 105% ~ 150% 13 Over Voltage Protection (∗5) - 165~240% 125% ~ 145% 14 Remote Sensing - Possible 15 Remote ON/OFF Control (*8) - Possible (Short : ON, Open : OFF) 16 Parallel Operation - ----17 Series Operation (∗8) - Possible 19 Operating Temperature (∗6) - -20 ~ +85°C (Baseplate) Ambient Temperature min = -20°C 20 Operating Humidity 30 ~ 95%RH (No dewdrop) 21 Storage Temperature - -40 ~ +85°C 22 Storage Humidity 10 ~ 95%RH (No dewdrop) 23 Cooling (∗7) - Conduction Cooled 24 Temperature Coefficient - 0.02% / °C 25 Withstand Voltage - Input - Baseplate : 2.5kVAC (20mA) for 1 minute. Input - Output : 3.0kVAC (20mA) for 1 minute. Output - Baseplate : 500VDC for 1 minute. 26 Isolation Resistance - More than 100MΩ at 25°C and 70%RH Output - Baseplate : 500VDC 27 Vibration - At no operating, 10 ~ 55Hz amplitude (sweep for 1minute) 0.825mm constant (Maximum 5G) X,Y,Z 1hour each. 28 Shock - Less than 20G (In Package) 29 Safety Standard UL1950 - Approved by UL (excluding PH150S280-3.3) CSA234 - Approved by CSA (excluding PH150S280-3.3) EN60950 - Approved by BSI (excluding PH150S280-3.3) 30 Weight (Typ) g 150g mm 72 x 12.7 x 86 (Refer to Outline Drawing) 31 Size (WxHxD) * Read instruction manual carefully, before using the power supply unit. MODEL =NOTES= ∗1. At 280VDC and maximum output current. ∗2. 200 ~ 400VDC input, constant load. ∗3. No load ~ Full load, constant input voltage. ∗4. Constant current limiting with automatic recovery. ∗5. Inverter shut-down method, manual reset. ∗6. Ratings - Refer to Derating Curve on the right. - Load (%) is percent of maximum output current. ∗7. Heatsink has to be chosen according to instruction manual. ∗8. Refer to instruction manual. ∗9. External components are needed for operation. (Refer to basic connection and instruction manual) Derating Curve 100 Load (%) C095-01-01B * : For delivery, contact to our sales office. * * PH150S PH150S PH150S PH150S 280-12 280-15 280-24 280-28 12 15 24 28 12.5 10.0 6.3 5.4 150 150 151.2 151.2 85 85 88 88 80 60 40 20 0 -20 0 20 40 60 85 80 100 Baseplate Temperature (°C) PH150S280 Specifications NEMIC-LAMBDA C095-01-02B 1. Basical Connection PH150S280 Power Module Measurement point for Vo load / line regulation +S Fuse ∗ 1 +Vin +V + C1 Vin 200~400VDC ∗2 C2 4700pF -Vin C3 R1 C4 ∗3 ∗4 1uF Load 2A - -V -S CNT L = 50mm TRM Baseplate Measurement point for output ripple & noise (EIAJ RC-9002A probe) Bandwidth of scope:100MHz = Note = ∗1. Use an external fuse of fast blow type for each unit. ∗2. When the input line impedance is high, insert input electrical capacitor. C1 : more than 22uF. (Refer to instruction manual) ∗3. Put an output capacitor C3. 3.3V, 5V : more than 1000uF 12V, 15V : more than 470uF 24V : more than 220uF 28V : more than 220uF ∗4. Set the minimum load current (more than 3% of rated current) in order to prevent recurrent output voltage dropout (due to continuous skip cycle) under dynamic load conditions. ∗5. Refer to instruction manual for further details.