CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications P Series UL Recognized CSA Certified VDE Approved PS Unfiltered PS000SS30 PS Filtered The P series power entry module offers fuller flexibility of design in a more compact package. H models provide susceptibility protection without leakage current associated with line-to-ground capacitors and are designed to allow equipment to meet UL 544 for patient care and non-patient care equipment. As the first 10 amp module to provide all five power entry functions in one compact design, the CHAMELEON module readily adapts to its environment and the needs of international markets. Also available is an interconnection block, B models. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with a switch and an IEC connector to reduce external wiring. • Snap-in or flange mounting L Models – High performance medical filter versions that are designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC part 15J, Class B) conducted emissions limits while additionally allowing equipment to meet UL544, UL2601and EN60601 for patient care equipment and non-patient care equipment. They are available with current ratings of 6 and 10 amps. High performance versions are available with horizontal mounting ears, single voltage, complete can shield with options for switch, fuses and current ratings only. Extenders are not available. P Series • IEC power line connector • Both North American and European fusing capabilities • Two voltage selections • Optional DPST on/off switch • Filtering options for general purpose, medical and high-performance applications. The CHAMELEON modules compact design and modular construction will allow you to select the power entry features you require — without altering the panel cutout. And the Chameleon module, with adapters, will fit any standard panel cutout. The CHAMELEON module has four filter options. S models offer protection for general purpose applications where line-to-ground and line-to-line noise must be controlled. The filters are designed to meet low leakage requirements of VDE portable equipment. They are available in current ratings of 3, 6 and 10 amps. Z Models – High performance filter versions are designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10 amps. High performance versions are available with horizontal mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses and current ratings only. PE Filter with "A" Shield 132 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series P Series Part Number Schematic Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. Mounting Extender Style Options* Switch Voltage Fuse Options ‡ Select ** Options Filter Type Filter Current Shield Options* P S J 0 X S S 6 0 Switch Option 0 = Blank S = Double pole single throw (DPST) Extender Option 0 = None C = FN260 J = J Series L = L Series Filter Current 0 = No filter 3 = 3 amps 6 = 6 amps X = 10 amps Fuse Options D = Dual fuse S = Single fuse Input Voltage Select 0 = Single voltage S = Dual voltage ** select (SMPS) X = Dual voltage ** select (series/parallel) Notes: An additional extender which allows the P series to adapt to Corcom's L series product cutout as well as the panel cutout of Schaffner and Delta parts is also available. • Extenders cannot be added to units with B shields † When using the interconnection block, the last 3 digits of the part number are BX (0, A, or B) ‡ For alternative switch orientation options, please contact technical sup port or your Corcom sales representative ** Dual voltage options only available with filter types O, H or S ••• High performance versions are available with horizontal mounting ears (PE style), no extenders, single voltage, complete can shield with options for switch, fuses, filter type (L or Z) and 6 or 10 amp current ratings only. Power Entry Modules Mounting Style E = Mounting ears (Horizontal) S = Snap-in M = Mounting ears (Vertical) Shield Options Filter Type 0 = No filter 0 = No shield B = Interconnection A = Filter shield B = Complete block ✝ Shield H = Medical Filter L = High Performance C = Complete can Medical (for L & Z models) S = General purpose Z = High Performance *** Extender for J-Series or others Fuse holder Optional switch The part number PSJ0XSS60 would represent the equivalent of the Corcom J Series 6J4:. P Series (P) with a snap-in mount (S) with the J extender to fit the 6J4 cutout(J), and includes no switch (0) dual voltage select (X) single fusing (S), general purpose filter (S) for 6 amps (6) with no shield (0). Optional filter Additional extender which allows the P series to adapt to CORCOM's L series product cutout, as well as the panel cutout of Schaffner and Delta parts is available. * Extenders cannot be added to units with B shields. 133 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Voltage Selection Input Voltage Selection Schemes The P series of power entry modules provides a dual voltage selector which is integrated with the fuseholder. To simplify the wiring in each individual application, Tyco Electronics provides dedicated voltage selectors for different voltage selection schemes. The two most popular schemes are the parallel and serial for dual primary transformers and the “DPST switch” for switching mode power supplies (jumper types.) P series products with an “S” as the fifth digit are specifically designed for “jumper” type applications associated with switching mode power supplies. P series products with an “X” as the fifth digit are specifically designed for dual primary transformer applications. The voltage selector installed will allow proper wiring from these applications. No matter what voltage selection scheme is used, wiring is always made to the same four terminals. X - Dual Primary Transformer Type 115V 230V Power on/off Hot G Note 1 A Note 2 B Ground Note 1 C Note 2 Neutral 115V 115V D H Transformer primary Provision for single fusing S - Jumper Type 115V 230V Power on/off Hot G Note 1 Note 1 Note 1 Note 1 B Ground Neutral A C H Power input Sel. Jumpers D SMPS Provision for single fusing Note 1: Jumpers are required if a filter or interconnection module is not used. Note 2: Location of optional filter. Jumpers are required if a filter or interconnection block is not used. Shield A new feature available on the P series is an RF shield. The metal shield, available on filtered models, provides shielding from radiated emissions and provides an additional RF ground for the filter to the case. The shield is available in two versions, a shield of the filter components (designated by A as the ninth digit) and a complete shield (designated by B as the ninth digit). The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from magnetic coupling. This shield improves RF ground connection to the case while still allowing the use of the P Series extender. The B shield covers the entire power entry module with metal, protecting the equipment from all radiated noise. Used with the filter, the shield provides the most secure protection from RFI noise problems. The B shield cannot be used with any extender. A Shield B Shield 134 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Fuseholder Power Entry Modules Another feature of the P series power entry module is a versatile fusing arrangement. Its fuseholder can hold two 1/4” x 1-1/4” or 5 x 20mm fuses. It can also be converted to accept one fuse with a conversion clip that bridges one of the two fuse chambers. The conversion clip is installed on the P Series power entry modules set for single fusing (those with part numbers with an “S” as the sixth digit). Units with a “D” as the sixth digit do not include a conversion clip. Fuseholder shown with 5x20mm fuse Conversion clip included for use in single fuse applications. Interconnection Block Also available is an interconnection block (B models). The block connects the voltage selection terminals of an unfiltered CHAMELEON module with a switch and an IEC connector to reduce external wiring. Installation of the unfiltered versions of the P series involves wiring of the IEC socket to the switch and the switch to the fuseholder. Labor can be eliminated by ordering the product with an interconnection block. This feature, designated by a BX in the seventh and eighth digits, pre wires the module for easier installation. The wiring is protected with the plastic case to better prevent access to the terminals and connections. The dimensions of this alternative are the same as the filtered versions. Interconnection Block installed in place of filer. Accessories A full range of accessories are available for the P Series. To simplify customer installation wiring can be simplified by ordering a PA100 connector assembly which is pre-wired with 6" of wire lead. See page 143 for a complete list of all accessories available for this series. PA100 Assembly 135 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Electrical Schematics Minimum insertion loss in dB: H Model Line-to-ground in 50 ohm circuit S Model Current .03 Rating H Models 03A 7 06A 10A 3 S Models 03A 7 06A 10A - .1 .15 Frequency-MHz .5 1 3 5 10 30 17 8 5 21 11 8 27 30 15 17 10 12 29 19 11 26 18 11 23 16 10 15 13 10 17 8 3 21 12 5 27 33 17 23 10 13 40 32 23 44 36 27 50 44 35 32 30 27 .1 Frequency-MHz .15 .5 1 5 10 30 27 22 30 37 24 27 43 32 49 52 52 47 42 40 27 22 29 34 23 24 35 25 25 21 21 18 16 14 10 30 48 40 40 41 35 32 50 55 55 45 45 45 L Model LINE LOAD Z Model LINE LOAD Specifications Maximum leakage current, each line-to-ground: † H & L Models S & Z Models @ 120 VAC 60 Hz: 2 µA .25 mA .50 mA @ 250 VAC 50 Hz: 5 µA †Applies to Filtered models only Hipot rating (one minute): line-to-ground 1500 VAC line-to-line 1450 VAC Operating frequency: 50/60 Hz Rated voltage: 250 VAC Operating voltages: 115/230 VAC Selectable or Fixed Rated current: Unfiltered – 10A Filtered – 3, 6 or 10A Switch: Double-insulated, rated for 10,000 operations at full load at 51 Amp inrush current. Fuseholder: Accepts one or two fuses 1/4 x 1-1/4 or 5 x 20 mm Conversion clip provided on fuseholder for single fuse models. Current Rating .01 .05 Z Models 06A 8 21 10A 5 17 L Models 06A 8 21 10A 5 17 Line-to-line in 50 ohm circuit Current Frequency-MHz Rating .10 .15 .5 1 3 5 H Models 03A 2 4 12 18 31 40 06A 2 4 12 16 26 35 10A 2 4 12 16 26 33 S Models 03A 2 4 12 15 30 48 06A 2 4 12 15 22 42 10A 2 4 12 15 22 42 Current Rating .01 .05 Z Models 06A 10 15 10 20 10A L Models 10 15 06A 10A 10 20 .1 Frequency-MHz 1 5 .15 .5 10 30 34 20 44 75 35 67 75 75 75 75 70 70 60 60 34 20 44 75 35 67 75 75 75 75 70 70 60 60 Terminals: Standard versions: .187 x 0.032 [4.8 x .81] terminal tabs High performance versions: .250 x 0.032 [6.4 x .81] terminal tabs Recommended for use with mating connector - no solder 136 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Case Styles PS/PSL .06 R Max 1.52 C E C (Note 1) .225 5.72 A .225 5.72 B1 D B2 Unfiltered Power Entry Modules .020 R Min .508 Panel Cutout Filtered Note1: For snap-in applications, the D sides of the cutout must have a .02 [.508] radius on the installation side. Snap-in models allow front mounting only. Not recommended for plastic panels. .06 R Max 1.52 PE E C C .020 R Min .508 .225 Max. 5.72 D B1 .225 Max. 5.72 D B2 F F Unfiltered A PM Panel Cutout Filtered A D D F E C .225 5.72 Max. B1 Unfiltered Typical dimensions: Terminals: .187 x 0.032 [4.8 x .81] terminal tabs Slot (Ground Terminal): .06 x .115 [1.52 x 2.92] ± .004 [.10] .225 5.72 Max. B2 F .06 1.52 R Max Filtered Panel Cutout Holes: .055 [1.5] Dia. ± .004 [.10] Mounting Holes (PE, PM only) : .135 [3.43] Dia. (2) countersunk 137 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Case Styles (continued) PSC/PSJ .06 R Max 1.52 C E (Note 1) .020 R Min .508 .225 5.72 Max. A B1 Unfiltered D .225 5.72 B2 Filtered Panel Cutout Note 1: For snap-in applications, the D sides of the cutout must have a .02 [.508] radius on the installation side. Snap-in models, allow front mounting only. Typical dimensions: Terminals: .187 x 0.032 [4.8 x .81] terminal tabs Slot (Ground Terminal): .06 x .115 [1.52 x 2.92] ± .004 [.10] Holes: .055 [1.5] Dia. ± .004 [.10] Mounting Holes (PE, PM only) : .135 [3.43] Dia. (2) countersunk PE High Performance 3.93 Max. C F .225 5.72 A 2.39 Max. 2.17 Max. B2 D Rear View Note 1: Use cutout for PE Style. Typical dimensions: Terminals: .250 x 0.032 [6.4 x .81] terminal tabs Slot (Ground Terminal): .07 x .16 [1.8 x 4.1] Holes: .07 [1.8] Dia. (2) Mounting Holes: .135 [3.43] Dia. (2) countersunk 138 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Shielding Case Dimensions Part No. A B1 B2 C (max) (max) (max) (max) PS PSL 2.19 Max PE 0.225 .508 Max. 2.19 Max A Shield B Shield Shields can be used only with filtered models. Shields add approximately 0.06" to depth. B shield may not be used with J or C extender. PM 1.93 1.24 2.13 1.93 PE High A B C D A B C D N L GND 2.31 1.12 2.201* 54.1 58.67 28.45 55.91 1.98 2.13 1.93 2.31 F — 55.91 31.49 49.02 — 1.122 2.201* 1.575 50.29 49.02 54.1 58.67 28.5 55.91 40.0 1.24 2.13 1.06 2.13 2.496 1.93 1.24 1.93 1.24 1.93 31.49 49.02 Rear View ∆ 2.201* 1.06∆ 54.1 58.67 26.93 31.49 49.02 PSJ 2.31 31.49 49.02 31.49 49.02 PSC 2.13 E 1.98 50.29 Performance — 2.9 54.1 73.66 26.93 54.1 63.4 2.13 2.52 — 2.51 1.06 54.1 63.75 26.93 64.01 2.13 2.72 1.06 2.6+ 54.1 69.09 26.93 4.42 Power Entry Modules 0.225 .508 Max. 1.24 D +.008/-.000 +.008/-.000 +.20/-.00 +.20/-.00 — 66.0 2.31 1.12 2.201 1.575 112.27 58.67 28.5 55.91 40.0 * Panel cutout for thickness of .031 - .079 [0.8 - 2.0]. For panel thickness at .083 - .114 [2.1 - 2.9] use 2.213 [56.21]. + Panel cutout for thickness of 0.06 - 0.09 [0.76 - 2.29]. ∆ For shielded models use D=1.12 +.008/-.000. GND Filtered Unfiltered 139 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com