ETC RMB962A1211351008

RMB962
miniature relays
1
• Height 15 mm • IP 67
• For PCB
• Insulation 4 kV / 8 mm
• High switching capacity, low power consumption
• Bistable relays with two coils • DC coils
• Terminals raster: type A - 3,2 mm for version 1 C/O,
type A - 5,0 mm for version 1 NO ❶
• Recognitions, certifications, directives: RoHS,
BISTABLE
2-COILS
Contact data
Number and type of contacts
Contact material
Max. switching voltage
Min. switching voltage
AC/DC
1 C/O, 1 NO
AgSnO2, AgCdO, AgCdO/Au 3,5 µm
400 V / 300 V
24 V AgSnO2, 24 V AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
Rated load
Min. switching current
AC1
8 A / 250 V AC
100 mA AgSnO2, 100 mA AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
AC1
10 A
8A
2 000 VA
2,4 W AgSnO2, 2,4 W AgCdO
AgCdO/Au 3,5 µm - contact Relpol S.A.
Contact resistance
Max. operating frequency
• at rated load
• no load
≤ 100 mΩ
AC1
3 600 cycles/hour
20 000 cycles/hour
Coil data
Rated voltage
Operating range of supply voltage
Duration of supply voltage pulse
DC
3...24 V ❷
see Table 1
min. 10 ms;
max. 5 s
Insulation
Insulation category
Insulation rated voltage
Insulation max. voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
• between coil and contacts
• contact clearance
Contact - coil distance
• clearance
• creepage
C250
250 V AC
400 V AC
4 000 V AC
III
PN-EN 60664-1
3
4 000 V AC
1 000 V AC
≥ 8 mm
≥ 8 mm
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive AC1
• cos φ = 0,4
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storage
• operating
Cover protection category
Environmental protection
Vibration resistance
Solder bath temperature
Soldering time
10 ms
7 ms
8 A, 250 V AC
> 105
> 105
5 A, 250 V AC
> 3 x 107
29 x 10 x 15 mm
10 g
-40...+80 oC
-40...+70 oC
IP 67
RTII
PN-EN 116000-3
10 g 10...100 Hz
max. 270 oC
max. 5 s
The data in bold type pertain to the standard versions of the relays.
Note: At IP 67 waterproof version it is recommended that the vent pin is removed after soldering and washing process.
❶ Relays with other rasters available - contact Relpol S.A.
❷ Supply of bistable relays RMB962 - see page 2
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
www.relpol.com.pl
RMB962
2
miniature relays
Supplying mode: energizing only in pulse mode. Min. pulse duration 10 ms; max. pulse duration 5 s.
Terminals raster: type A
1 C/O - raster A (3,2 mm)
1 NO - raster A (5,0 mm)
1 C/O - raster A (3,2 mm)
1 NO - raster A (5,0 mm)
Mounting openings raster ❶
(solder side view)
1 C/O - raster A (3,2 mm)
Two coils circuit
1 NO - raster A (5,0
mm)
Mounting
Relays RMB962 (raster A (3,2 / 5,0 mm)) are designed for direct PCB mounting.
www.relpol.com.pl
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
RMB962
miniature relays
3
Ordering codes
Cover protection
category
Type
Type of raster
Contact
material
Number and type
of contacts
Connection
mode
Coil code
Coil type
2 - bistable, two coils
Type of raster ❶
see Table 1 page 2
A - 3,2 / 5,0 mm raster
Contact material
10 - AgCdO
12 - AgCdO/Au 3,5 µm
30 - AgSnO2
Number and type of contacts
11 - 1 C/O
21 - 1 NO
Cover protection category
3 - in cover, IP 67 waterproof version
❶ Relays with other
rasters available
- contact Relpol S.A.
Connection mode
5 - for PCB
Examples of ordering codes:
RMB962A-3011-35-1012
bistable relay RMB962 with two coils, contact material AgSnO2, with one changeover
contact - raster type A (3,2 mm), in cover IP 67, for PCB, voltage version 12 V DC
RMB962A-3021-35-1012
bistable relay RMB962 with two coils, contact material AgSnO2, with one normally open
contact - raster type A (5,0 mm), in cover IP 67, for PCB, voltage version 12 V DC
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900