DESCRIPTION BY APPD DATE A RELEASED PER ER5435 CWB 2. MATERIAL SPECIFICATIONS: CENTER CONTACT, SLEEVE AND BUSHING: BRASS PER ASTM B16. BODY, OUTER CONTACT, AND FERRULE: COPPER ALLOY INSULATOR: TEFLON PER ASTM D1710 REV CWB 11/28/07 NOTES: UNLESS OTHERWISE SPECIFIED 1. FOR GENERAL SERIES SPECIFICATIONS, SEE SD12-0000. 3. FINISH SPECIFICATIONS: CENTER CONTACT: .000050 MIN GOLD PER ASTM B488 OVER .000100 MIN COPPER PER ASTM B734 (RoHS) ALL OTHER METAL PARTS: .000080 MIN TRI-METAL OVER .000100 MIN COPPER PER ASTM B734 (RoHS) FERRULE: .000010 MIN TRI-METAL OVER .000100 MIN COPPER PER ASTM B734 (RoHS) 4. FERRULE AND CONTACT SHIPPED LOOSE. 5. DESIGNED FOR USE WITH RG55/U, 142, 223, 400 AND EQUIVALENT CABLES. 6. CRIMP FERRULE USING .213 HEX DIE. 7. MATES WITH STANDARD TYPE N INTERFACE PER MIL-STD-348A, FIG 304.2 (.187±.015 THREAD LENGTH). 8. ELECTRICAL SPECIFICATIONS: FREQUENCY RANGE: DC-11GHz VSWR: 1.15 MAX (1.72 43.7 ) WHEN ASSEMBLED .880 22.35 TO TOP OF INNER CABLE CONDUCTOR .250 6.35 .375 9.53 .121 3.07 .042 1.07 .219 5.56 .84 21.3 CATALOG P/N: 120-900-1161R .625 15.88 .270 6.86 .110 2.79 PER ASME Y14.5M-1994 UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES [MM] TOLERANCES: DECIMAL: .XX ± .01 [0.3] .XXX ± .005 [0.13] .XXXX ± .XXXX ANGLES: ± 2° SCALE: 2:1 CUSTOMER DRAWING CABLE TRIM DIMENSIONS DRAWN PSM APPROVED JC DATE APPROVED 11/14/05 DC DATE APPROVED 11/28/07 M.AYUB DATE 11/28/07 DATE 11/28/07 WinchesterElectronics Winchester Electronics Corporation 62 Barnes Industrial Road North Wallingford, Connecticut 06492 QC-N STRAIGHT PLUG CRIMP ATTACHMENT A SD120-900-1161R SHT 1 OF 1 REV A