TI SN64BCT2827C

SCBS415 − APRIL 1987 − REVISED NOVEMBER 1993
•
•
•
•
•
•
•
DW OR NT PACKAGE
(TOP VIEW)
State-of-the-Art BiCMOS Design
Significantly Reduces ICCZ
ESD Protection Exceeds 2000 V Per
MIL-STD-883C, Method 3015; Exceeds
200 V Using Machine Model (C = 200 pF,
R = 0)
Output Ports Have Equivalent 33-Ω Series
Resistors, So No External Resistors Are
Required
High-Impedance State During Power Up
and Power Down
3-State Outputs Drive Bus Lines or
Buffer-Memory Address Registers
Flow-Through Architecture Optimizes PCB
Layout
Package Options Include Plastic
Small-Outline (DW) Packages and Standard
Plastic 300-mil DIPs (NT)
OE1
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
GND
1
24
2
23
3
22
4
21
5
20
6
19
7
18
8
17
9
16
10
15
11
14
12
13
VCC
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
Y10
OE2
description
This 10-bit buffer and bus/MOS driver provides a high-performance bus interface for wide data paths or buses
carrying parity.
The 3-state control gate is a 2-input AND gate with active-low inputs so that if either output-enable (OE1 or OE2)
input is high, all ten outputs are in the high-impedance state. The outputs are also in the high-impedance state
during power-up and power-down conditions. The outputs remain in the high-impedance state while the device
is powered down.
The outputs, which are designed to source or sink up to 12 mA, include 33-Ω series resistors to reduce overshoot
and undershoot.
The SN64BCT2827C is characterized for operation from − 40°C to 85°C and 0°C to 70°C.
FUNCTION TABLE
INPUTS
OE1
OE2
A
OUTPUT
Y
L
L
L
L
L
L
H
H
H
X
X
Z
X
H
X
Z
Copyright  1993, Texas Instruments Incorporated
!"#$%&" ' ()##*& %' "! +),-(%&" .%&*/
#".)(&' ("!"#$ &" '+*(!(%&"' +*# &0* &*#$' "! *1%' '&#)$*&'
'&%.%#. 2%##%&3/ #".)(&" +#"(*''4 ."*' "& *(*''%#-3 (-).*
&*'&4 "! %-- +%#%$*&*#'/
• DALLAS, TEXAS 75265
• HOUSTON, TEXAS 77251−1443
POST OFFICE BOX 655303
POST OFFICE BOX 1443
1
SCBS415 − APRIL 1987 − REVISED NOVEMBER 1993
logic symbol†
1
OE1
OE2
13
logic diagram (positive logic)
OE1
&
OE2
EN
1
13
2
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
2
3
23
1
22
4
21
5
20
6
19
7
18
8
17
9
16
10
15
11
14
23
A1
Y1
Y1
Y2
Y3
Y4
To Nine Other Channels
Y5
Y6
Y7
Y8
Y9
Y10
† This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
schematic of each output
VCC
Output
GND
2
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
SCBS415 − APRIL 1987 − REVISED NOVEMBER 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Voltage range applied to any output in the disabled or power-off state, VO . . . . . . . . . . . . . . . −0.5 V to 5.5 V
Voltage range applied to any output in the high state, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30 mA
Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 mA
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input negative-voltage rating may be exceeded if the input clamp-current rating is observed.
recommended operating conditions (see Note 2)
MIN
NOM
MAX
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IIK
Low-level input voltage
0.8
V
Input clamp current
−18
mA
IOH
IOL
High-level output current
−1
mA
Low-level output current
12
mA
∆t /∆VCC
Power-up ramp rate
High-level input voltage
2
V
µs / V
2
TA
Operating free-air temperature
NOTE 2: Unused or floating inputs must be held high or low.
V
−40
85
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
TEST CONDITIONS
MIN
TYP‡
MAX
UNIT
−1.2
V
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = −18 mA
IOH = − 1 mA
VOL
VCC = 4.5 V
IOL = 1 mA
IOL = 12 mA
II
IIH
VCC = 5.5 V,
VCC = 5.5 V,
VI = 7 V
VI = 2.7 V
0.1
20
µA
IIL
VCC = 5.5 V,
VCC = 0 to 2.3 V (power up)
VI = 0.5 V
−0.2
mA
IOZ
IOZH
IOZL
IOL(sink)
IO§
ICCL
ICCZ
Ci
VCC = 1.8 to 0 (power down)
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 4.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5.5 V,
VCC = 5 V,
VO = 2.7 or 0.5 V,
VCC −2
V
0.15
0.5
0.35
0.8
± 20
OE = 0.8 V
± 20
VO = 2.7 V
VO = 0.5 V
VO = 2 V
VO = 2.25 V
V
mA
µA
A
20
µA
−20
µA
50
mA
−30
−112
mA
Outputs open
28
40
mA
Outputs open
3.8
6
mA
VI = VCC or GND
VO = VCC or GND
5
pF
Co
VCC = 5 V,
8
pF
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ The output conditions have been chosen to produce a current that closely approximates one half ot the true short-circuit output current, IOS.
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
3
SCBS415 − APRIL 1987 − REVISED NOVEMBER 1993
switching characteristics over recommended range of supply voltage, CL = 50 pF (unless
otherwise noted) (see Note 3)
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A
Y
tPZH
tPZL
OE
Y
tPHZ
tPLZ
OE
Y
PARAMETER
TA = − 40°C
to 85°C
VCC = 5 V,
TA = 25°C
TYP
MAX
MIN
MAX
MIN
MAX
0.9
3.6
5.2
0.9
6.6
0.9
6
2
5.1
7.2
2
8.2
2
7.8
2.8
5.6
8
2.8
11.5
2.8
10.7
5
8.9
11
5
13.7
5
12.9
3.2
6.7
10.5
3.2
14
3.2
13
2.7
5.3
8.5
2.7
11
2.7
10
•
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
•
UNIT
MIN
NOTE 3: Load circuits and voltage waveforms are shown in Section 1.
4
TA = 0°C
to 70°C
ns
ns
ns
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Amplifiers
Data Converters
DLP® Products
DSP
Clocks and Timers
Interface
Logic
Power Mgmt
Microcontrollers
RFID
RF/IF and ZigBee® Solutions
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
dsp.ti.com
www.ti.com/clocks
interface.ti.com
logic.ti.com
power.ti.com
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/lprf
Applications
Audio
Automotive
Broadband
Digital Control
Medical
Military
Optical Networking
Security
Telephony
Video & Imaging
Wireless
www.ti.com/audio
www.ti.com/automotive
www.ti.com/broadband
www.ti.com/digitalcontrol
www.ti.com/medical
www.ti.com/military
www.ti.com/opticalnetwork
www.ti.com/security
www.ti.com/telephony
www.ti.com/video
www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2009, Texas Instruments Incorporated