4.25Gb/s Fibre Channel CWDM SFP Transceiver SPC-4F-01-xxCDA Features • Single 3.3 V supply • 10 km reach • Supports 1.06/2.125/4.25Gb/s Fibre Channel Operation • Compatible with 1.25Gb/s Ethernet • 18 CWDM wavelengths, DFB Laser • SFP MSA SFF-8074i compliant • Digital Diagnostic SFF-8472 compliant • Telcordia GR-468 compliant • RoHS Compliant General Operating Parameter Symbol Min. Typical Max. Unit Supply Voltage Vcc 3.135 3.3 3.465 V Total Current Icc - - 300 mA Power Supply Noise Rejectiona PSR 100 - - mVp-p Operating Case Temperature Top -5 - 70 ºC Storage Temperature Tst -40 - 85 ºC Data Rate FC-400 Fibre Channel DR - 4250 - Mbps a) 20Hz to 155MHz Transmitter Specifications (Optical) Parameter Symbol Min Typical Max Unit Optical Power Pop -5 -2.5 0 dBm Average Launch Power Of Off Tx Poff - - -45 dBm - - - Fibre Channel Compliant - - 130 ps 130 ps 1xxx 1xxx+6.5nm nm nm Eye Mask Optical Rise Timeb tr Timeb tf - λ 1xxx-6.5nm Optical Fall Mean Wavelength ∆λ20 - - 1 Dispersion Penalty (10 Km)c dp - 0.5 1 dB Relative Intensity Noise RIN - - -120 dB/Hz Reflection Toleranced rp -24 - - dB Spectral Width (20dB) b) 20%-80% values c) Measured at BER of 1e-12, PRBS of 27-1, at eye center d) 1 dB degradation of receiver sensitivity LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS1663-Apr0908 Rev. A.0 4.25Gb/s Fibre Channel CWDM SFP Transceiver SPC-4F-01-xxCDA Transmitter Specifications (Electical) Parameter Symbol Min Typical Max Unit Rin 80 100 120 Ω PECL Single Ended Data Input Swing Vin,p-p 250 - 1200 mV TxFault_Fault Vfault 2 - Vcc V Vnormal Vee - Vee+0.5 V Vd 2 - Vcc V Ven Vee - Vee+0.8 V Symbol Min Typical Max Unit Rsens,low - -18 -16 dBm Input Differential Impedence TxFault_Normal TxDisable_Disable TxDisable_Enable Receiver Specifications Parameter Receive Power Lowe Receive Power Highe Damage Threshold For Receiver Wavelength Maximum Reflectance Of Receiver Rsens,high -3 - - dBm Pin,damage 4 - - dBm λ 1200 - 1625 nm RX_r - - -27 dB -26 - - dBm LOS De-assert - - -16 dBm LOS Hysteresis 0.5 - - dB LOS Assert e) 10-12 BER, PRBS 27-1 Electrical Output Parameter Symbol Min Typical Max Unit PECL Single Ended Data Output Swing Vout, p-p 185 - 800 mV Data Output Rise Time tr - - 175 ps Data Output Fall Time tf - - 175 ps Timing and Electrical Parameter Symbol Min Typical Max Unit t_on - - 50 µs Tx Disable Assert Time t_off - - 10 µs Time To Initialize, Including Reset Of Tx Fault t_init - - 200 ms Tx Disable Negate Time Tx Fault Assert Time t_fault - - 100 µs Tx Disable To Reset t_reset 10 - - µs t_loss_on - - 100 µs LOS Assert Time LOS De-assert Time t_loss_off - - 100 µs Serial ID Clock Rate f_serial_clock 2 - 100 KHz 2 - Vcc V RX_LOS Voltage (High) RX_LOS Voltage (Low) LOS Output Voltage-Fault LOS Output Voltage-Normal - - 0.8 V VLOS fault 2 - Vcc V VLOSnormal Vee - Vee+0.5 V MOD_DEF (0:2)-High VH 2 - Vcc V MOD_DEF (0:2)-Low VL Vee - Vee+0.5 V LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS1663-Apr0908 Rev. A.0 4.25Gb/s Fibre Channel CWDM SFP Transceiver SPC-4F-01-xxCDA λ Wavelength Ordering SPC-4F-01-xxCDA See table below for “XX” values λc Wavelength Guide Code λC Unit Code λC Unit Code λC Unit 27 1271 nm 39 1391 nm 51 1511 nm 29 1291 nm 41 1411 nm 53 1531 nm 31 1311 nm 43 1431 nm 55 1551 nm 33 1331 nm 45 1451 nm 57 1571 nm 35 1351 nm 47 1471 nm 59 1591 nm 37 1371 nm 49 1491 nm 61 1611 nm Diagnostics Parameter Range Accuracy Unit Calibration Temperature(-CDA) -5 to 70 ±3 ºC External Voltage 0 to Vcc 0.1 V External V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset Bias Current 0 to 120 5 mA External I(mA)=Islope*Iad(16 bit unsigned integer)+Ioffset TX Power -5 to 0 ±3 dB dBm External TX_PWR(µW)=TX_PWRslope*TX_PWRad(16 bit unsigned integer +TX_PWRoffset RX Power -16 to -3 ±3 dB dBm External RX_PWR(µW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4 LUMINENTOIC.COM Formula Tc(C) = Tslope*Tad(16 bit signed twos complement value) + Toffset 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS1663-Apr0908 Rev. A.0 4.25Gb/s Fibre Channel CWDM SFP Transceiver SPC-4F-01-xxCDA EEPROM Serial ID Name of Field Vendor Name Vendor OUI Vendor PN LUMINENTOIC.COM Description of Field SFP Vendor Name(ASCII) IEEE Vendor OUI Code For LuminentOIC Inc. Part Number in ASCII, e.g. SPC-4F-01-xxCDA Address Hex ASCII 20 4C L 21 55 U 22 4D M 23 49 I 24 4E N 25 45 E 26 4E N 27 54 T 28 4F O 29 49 I 30 43 C 37 00 38 06 39 B5 40 53 41 50 P 42 43 C 43 34 4 44 46 F 45 30 0 46 31 1 47 x x 48 x x 49 43 C 50 44 D 51 41 A 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 S LUMNDS1663-Apr0908 Rev. A.0 4.25Gb/s Fibre Channel CWDM SFP Transceiver SPC-4F-01-xxCDA Function Pin Notes 1 VeeT TX GND 2 TX_FAULT Open Collector 3 TX_DISABLE Internally Pulled High 4 MOD_DEF2 Serial Data Input 5 MOD_DEF1 Serial Clock Input 6 MOD_DEF0 Internally Grounded 7 NC Not Connected 8 LOS Open Collector 9 VeeR RX Ground 10 VeeR RX Ground 11 VeeR RX Ground 12 RXD- RX Data Negative 13 RXD+ RX Data Positive 14 VeeR RX GND 15 VccR RX Power 16 VccT TX Power 17 VeeT TX GND 18 TXD+ TX Data Positive 19 TXD- TX Data Negative 20 VeeT TX GND LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS1663-Apr0908 Rev. A.0 4.25Gb/s Fibre Channel CWDM SFP Transceiver SPC-4F-01-xxCDA Outline Drawing Units in mm(inches) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS1663-Apr0908 Rev. A.0 4.25Gb/s Fibre Channel CWDM SFP Transceiver SPC-4F-01-xxCDA Suggested Transceiver Interface 1�H Vcc 10�F 1�H 0.1�F VCCT .01�F Protocol IC LuminentOIC SFP 10K� R1 TX_DISABLE TX_DISABLE TX_FAULT TX_FAULT TD + SerDes Laser Driver .01�F 100� TD VEET .01�F VCCR 10�F 0.1�F RD + Receiver Amplifier .01�F 100� RD - RX_LOS RX_LOS Vcc R VEER 1 R1 R1 .01�F EEPROM R1 MOD_DEF 2 MOD_DEF 1 MOD_DEF 0 R1=4.7K to 10K� LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS1663-Apr0908 Rev. A.0 4.25Gb/s Fibre Channel CWDM SFP Transceiver SPC-4F-01-xxCDA Ordering Information Available Options: SPC-4F-01-xxCDA Part Numbering Definition: SPC-4F - Reach - xx Temperature Diagnostic Revision SPC = CWDM SFP 4F = 4x Fibre Channel 01 = 10 km xx = 27 to 61 Operating Temperature C = Commercial (-5 to 70) D = Digital Diagnostic A = Design Revision Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at Luminent’s sole and absolute discretion. Luminent warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and Luminent makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. Luminent customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify Luminent for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that Luminent is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © Luminent, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 8 LUMNDS1663-Apr0908 Rev. A.0