tfs125d.doc version 2.0 VI TELEFILTER Filter specification 21.02.2002 TFS 125 D 1/5 Measurement Condition Ambient Temperature: Input Power Level: Source impedance: Load impedance: Terminating impedances: *) input: output: 23 °C 0 dBm 50 Ω single ended 50 Ω single ended 175 Ω || -22.5 pF 200 Ω || -22.7 pF Characteristics Remark: The reference level for the relative attenuation arel of TFS 125D is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 125,0 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo. Data typ. Value Insertion Loss (Reference level) ae = amin - Nominal Frequency fN - 3 dB - Bandwidth BW Pass Band Ripple Limit max. 8 dB 125,0 MHz min. 400 kHz - max. - min. min. min. min. 20 35 20 20 dB dB dB dB Group delay fN - max. 1 µs Group delay ripple fN – 80 kHz ... fN + 80 kHz - max. 1 µs Input power level - max. + 10 Relative Attenuation 1,8 MHz ... fN ± 6 MHz ... fN ± MHz ... fN - 124 39 MHz ... fN + arel fN ± 6 MHz fN ± 39 MHz fN 39 MHz fN + 775 MHz Operating Temperature Range Storage Temperature Range 1,0 dB dBm - 5 °C ... + 75 °C - 40 °C ... + 85 °C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. Generated: Checked / approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs125d.doc version 2.0 VI TELEFILTER Filter specification TFS 125 D 21.02.2002 2/5 Construction and pin configuration Datecode TFS 125D P08 1 2 Output Ground Ground Ground Ground Input Ground Ground Ground Ground Datecode: M N P ... Year+week 2000 2001 2002 3 10 4 9 5 8 1 2 3 4 5 6 7 8 9 10 7 6 50 Ω single ended test circuit L2 L1 6 Input 1 Output 50 Ohm SAW 50 Ohm C1 C2 2,3,4,5,7 8,9,10 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs125d.doc version 2.0 VI TELEFILTER Filter specification 21.02.2002 TFS 125 D 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dim en sio ns in m m ) W Po : : 16 4 Do E : : 1,5 + 0,1 1,75 ± 0,1 F : G (m in) : P2 : P1 : D 1(m in) : 2000 min 300 mm min 500 mm min 300 mm E M B OS SE D CA RR IE R TA P E ± 0,3 ± 0,1 Do Po P2 E Ao 7,5 ± 0,1 0,60 2 12 1,5 ± 0,1 ± 0,1 F D1 W Bo CT G Ao Bo : : 7,60 ± 0,1 9,60 ± 0,1 CT : 13,5 P1 ± 0,1 C OV E R TA P E W2 Reel (all dimensions in mm): A : W1 : W2 (max) : 330 16,40 +2,0 22,4 N (min) : 60 C : 12,8 + 0,1/-0.1 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs125d.doc version 2.0 VI TELEFILTER Filter specification 21.02.2002 TFS 125 D 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs125d.doc version 2.0 VI TELEFILTER Filter specification 21.02.2002 TFS 125 D 5/5 History Version Reason of Changes Development specification 1.0 - generation of development specification Filter specification 2.0 - terminating impedances added - temperature range corrected Name Date Steiner 17.04.1999 Steiner 21.02.2002 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.