POWER-ONE ABC150

DATA SHEET
ABC150 SERIES 150W AC/DC
FEATURES

110 W convection cooled

-20 to 50 deg C full load operation

90-264 VAC input

2” x 4” x 1.3” (101.6 x 50.8 x 33.6 mm)

No minimum load required

Fan output, 12 Vdc @ 0.5A standard

Conducted EMI EN 55022-B, FCC Part 15 Level B

ITE Safety Agency Approvals

RoHS Compliant
APPLICATIONS

Instrumentation

Renewable Energy

Lighting

Wireless Data

Industrial Applications

Automation Control

Test and Measurement

Applied Computing
BCD.00283_AA_September-18-2013
1
www.power-one.com
DATA SHEET
TECHNICAL DATA:
Input
PARAMETER
DESCRIPTION/CONDITION
Input voltage range
Universal Input
Input frequency range
47-63 Hz
Input surge current
230 Vac (cold start)
65 A max.
Safety ground leakage current
230 Vac
120 Vac @ 150 W
230 Vac @ 150 W
< 300 μA
1.7 A
0.85 A
Input current
90 - 264 Vac
120 – 390 Vdc
Output
PARAMETER
DESCRIPTION/CONDITION
Voltage Adjustment
V1
± 3%
Transient Response
Main output 50 to 100% load change, 50
Hz, 50% duty cycle, 0.1A / uSec
< 10%, recovery time < 5 mSec
Over Voltage Protection
V1
110 to 150% rated max
Over Current Protection
Rated output current
110% Typical
Short Circuit Protection
Automatic recovery
Efficiency
>86%
Set Point Accuracy
± 1%
Rise Time
< 100 mSec
Ordering Information
PRODUCT FAMILY
VOLTS
MAX LOAD
MAX LOAD
(VDC) CONVECTION (1) 300 LFM (1)
MINIMUM
LOAD (A)
RIPPLE &
NOISE (4)
CONNECTOR
TOTAL
REGULATION
ABC150-1005G
5.0
16.0 A
16 A
0
1%
JST
± 2.5%
ABC150-1T05G
5.0
16.0 A
20 A
0
1%
Screw Terminal
± 2.5%
ABC150-1012G
12
8.33 A
12.5 A
0
1%
JST
± 2.5%
ABC150-1T12G
12
8.33 A
12.5 A
0
1%
Screw Terminal
± 2.5%
ABC150-1015G
15
6.67 A
10.0 A
0
1%
JST
± 2.5%
ABC150-1T15G
15
6.67 A
10.0 A
0
1%
Screw Terminal
± 2.5%
ABC150-1024G
24
4.17 A
6.25 A
0
1%
JST
± 2.5%
ABC150-1T24G
24
4.17 A
6.25 A
0
1%
Screw Terminal
± 2.5%
ABC150-1048G
48
2.08 A
3.13 A
0
1%
JST
± 2.5%
ABC150-1T48G
48
2.08 A
3.13 A
0
1%
Screw Terminal
± 2.5%
Vfan (all models)
12
0.5 A (3)
0.5 A (3)
0
ABC150 Series
2
20%
www.power-one.com
DATA SHEET
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Combined power from main output and Vfan should not exceed total power rating.
Fan output tolerance is ± 20%
Peak power for fan output is 1 A.
Ripple is 2% up to 20% load and less than 1% above 20% load. Output noise measurement is made with a 20 MHz
bandwidth using a 6” twisted pair, terminated with a 10 uF tantalum capacitor in parallel with a 0.1 uF ceramic capacitor.
Specifications are for nominal input voltage, 25° C and max load unless otherwise stated.
Air flow over length of supply recommended (either direction) for forced air rating.
Class 1 models have Earthing tab J4. Class 2 models (-2 suffix) have no Earthing tab.
Specifications subject to change without notice.
Warranty 2 years.
General Specifications
PARAMETER
Hold Up Time
MTBF
Switching Frequency
Isolation Voltage
Weight
DESCRIPTION/CONDITION
120 Vac
230 Vac
>200 khrs
PFC converter variable 35 to 250 kHz, 90
kHz typical
Input to Output Min 4242 Vdc
150 g (0.33 lbs)
6 mSec
10 mSec
Bellcore TR-332
Resonant converter: Variable 35 to 250
kHz, 90 kHz typical
Input to Ground 2120 Vdc
Environmental
PARAMETER
Operating Temperature
Altitude
Conducted emissions:
Humidity
Radiated Emissions
Electromagnetic Susceptibility
Harmonic Current
DESCRIPTION/CONDITION
Operating
Storage
Operating 10,000 ft.
EN55022, FCC part 15 Level B
95%
EN55022, FCC part 15 Level B
EN61000-4-2 Level 3
EN61000-3-2, Class D
-20 to +70° C. See derating chart below.
-40 to +85° C
Non-operation 40,000 ft.
Non-Condensing
To be controlled in end system
2, 3, 4, 5 Level 3
Safety
PARAMETER
DESCRIPTION/CONDITION
EN / UL / CSA
EN60950-1+A12:2011, IEC60950-1 2nd+A1 2009, CSA-22.2 No 60950-01-07+ A1,
UL60950-1-2011
BCD.00283_AA_September-18-2013
3
www.power-one.com
DATA SHEET
Figure 1 Output Power Vs. Temperature
Figure 2 Dimension Drawing (Top and Side View)
Mechanical
INPUT = J1
EARTHING TAB = J4
DC OUTPUT = J2
Pin 1: AC Line
Pin 2: AC Neutral
Molex: 19705-4301
Pin 1 = V1
Pin 2 = V1
Pin 3 = RTN
Pin 4 = RTN
Mating Connector:
Molex: 09-50-3031
Pins: 08-50-0106
Mating Connector:
Molex: 190030001
Mating Connector:
JST VHR-4M, Pins: SVH-41T-P1.1
AWG #20 to #16
FAN= J3
Pin 1 = +12 V @ 0.5 A
Pin 2 = Fan return
(isolated from DC output)
Mating Connector:
Tyco: 640440-2
Copyright © 2010 Power-One Inc. All rights reserved. Words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the
trademarks and service marks of Power-One Inc. in the U.S. and other countries. All other product or service names are the property of their respective holders.
Power-One products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Power-One reserves the
right to make changes to any products and services at any time without notice. Power-One assumes no responsibility or liability arising out of the application or use
of any information, product, or service described herein except as expressly agreed to in writing by Power-One Inc.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
ABC150 Series
4
www.power-one.com