ACX302AK 8.80cm (3.5 Type) NTSC/PAL Color LCD Panel Description The ACX302AK is a 8.80cm diagonal active matrix TFT-LCD panel addressed by low temperature polycrystalline silicon transistors with built-in peripheral driving circuitry. This panel provides fullcolor representation for NTSC and PAL systems. In addition, RGB dots are arranged in a delta pattern that provides smooth picture quality without fixed color patterns compared to vertical stripe and mosaic patterns. Features • Number of active dots: 200,000, 8.80cm (3.5 Type) in diagonal • Horizontal resolution: 440 TV lines • Optical transmittance: 8.2% (typ.) • High contrast ratio with normally white mode: 200 (typ.) • Built-in H and V driving circuitry (built-in input level conversion circuit, 3V drive possible) • Low voltage, low power consumption 12V drive: 60mW (typ.) • Smooth pictures with a RGB delta arrangement • Supports NTSC/PAL • Built-in picture quality improvement circuit • Up/down and/or right/left inverse display function • 16:9 screen display function • AR (anti-reflectance) surface treatment provides an easy-to-see display even outdoors • Dirt-resistant surface treatment • Narrow frame • High color reproductivity Element Structure • Active matrix TFT-LCD panel with built-in peripheral driving circuitry using low temperature polycrystalline silicon transistors • Number of pixels Total number of dots : 884 (H) × 230 (V) = 203,320 Number of active dots : 880 (H) × 228 (V) = 200,640 • Panel dimensions Package dimensions : 78.8 (W) × 63.3 (D) × 2.2 (H) (mm) Effective display dimensions : 70.400 (H) × 52.725 (V) (mm) Applications LCD monitors, etc. Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits. –1– E99419A9Z-PS ACX302AK Block Diagram The panel block diagram is shown below. H Level Shifter & Shift Register COM LC V Shift Register V Shift Register CS Negative Voltage Generation Circuit COM VST VCK EN DWN VVDD VSS HVDD VSSG TEST2 17 18 19 20 21 22 23 24 TESTR TESTL –2– 16 RGT 11 12 13 14 15 BLUE 10 RED 9 GREEN 8 PSIG 7 HCK1 6 HCK2 5 TEST1 4 REF 3 HST 2 WIDE 1 Cext/Rext V Level Shifter Common Voltage ACX302AK Absolute Maximum Ratings (Vss = 0V) • H driver supply voltage HVDD, Cext/Rext • V driver supply voltage VVDD • V driver negative supply voltage VSSG • Common voltage of panel COM • H driver input pin voltage HST, HCK1, HCK2, RGT, WIDE • V driver input pin voltage VST, VCK, EN, DWN, REF • Video signal, uniformity improvement signal input pin voltage GREEN, RED, BLUE, PSIG • Operating temperature Topr • Storage temperature Tstg –1.0 to +17 –1.0 to +15 –3.0 to +1.0 –1.0 to +17 –1.0 to +17 –1.0 to +15 V V V V V V –1.0 to +13 –10 to +60 –30 to +85 V °C °C Operating Conditions 1. Input/output supply voltage conditions∗1 Item (Vss = 0V) Symbol Supply voltage Min. Typ. Max. Unit HVDD 11.4 12.0/13.5 14.0 V VVDD 11.4 12.0/13.5 14.0 V HVDD – 2.0 12.0/13.5 — V –2.3 –1.8 –1.5 V Cext/Rext∗2 VSSG output voltage setting∗3 VSSG ∗1 The HVDD/VVDD typical voltage setting is noted as 12.0V in these specifications. ∗2 Connect the resistor and capacitor to the Cext/Rext pin as shown in the figure below. ∗3 For the VSSG output setting, connect an external smoothing capacitor and a voltage stabilizing Zener diode as shown in the figure below. The Cext/Rext value differs according to the rising time of the panel supply voltage. ACX302AK HVDD HVDD Voltage HVDD VSSG Cext/Rext Rext 1µF HVDD – Cext/Rext 7 text Cext/Rext Cext Time Set a Cext value that satisfies text > 1ms. –3– VSS Use a Zener voltage of 2.7V. (RD2.7UM is recommended.) ACX302AK 2. Input signal voltage conditions Item H/V driver input voltage (Vss = 0V) Symbol Min. Typ. Max. Unit (Low) VIL –0.3 0.0 0.3 V (High) VIH 2.6 3.0 5.5 V VIH/2 – 0.3 VIH/2 VIH/2 + 0.3 V REF input voltage VREF Video signal center voltage VVC 5.3 5.5 5.7 V Video signal input range Vsig 1.0 VVC ± 4.0 VVDD – 2.0 (however, 10V or less) V Uniformity improvement signal Vpsig VVC ± 2.3 VVC ± 2.5 VVC ± 2.7 V 16:9 display top/bottom black signal∗4 VpsigBK VVC ± 4.0 VVC ± 4.5 V Common voltage of panel (Ta = 25°C) Vcom VVC – 0.3 VVC – 0.2 V VVC – 0.4 ∗4 Input video and uniformity improvement signals should be symmetrical to VVC. The input conditions for the uniformity improvement signal Vpsig differ for 4:3 display and 16:9 display. 1) During 4:3 display, input the voltage amplitude symmetrical to VVC as shown in Fig. 1. 2) During 16:9 display, input the same signal amplitude as in 1) above during the effective display portion, and input the black signal level VpsigBK during the top/bottom black input portion as shown in Fig. 2. During 4:3 display PSIG VVC Vpsig Fig. 1 During 16:9 display PSIG VVC Vpsig VpsigBK VVC ± 4.0V VVC ± 2.5V Top/bottom black display portion (letterbox portion) Effective display portion Fig. 2 –4– ACX302AK Pin Description Pin No. Symbol Panel test output; no connection 13 HST Start pulse input for H shift register drive COM Common voltage input of panel 14 REF Level shifter circuit REF voltage input 3 VST Start pulse input for V shift register drive 15 TEST1 Panel test output; no connection 4 VCK Clock input for V shift register drive 16 Cext/ Rext Time constant power supply input for H shift register drive 5 EN Gate selection pulse enable input 17 HCK2 Clock input for H shift register drive 6 DWN V shift register drive direction signal input 18 HCK1 Clock input for H shift register drive 7 VVDD Power supply input for V driver 19 PSIG Uniformity improvement signal input 8 VSS H and V driver GND 20 GREEN Video signal (G) input to panel 9 HVDD Power supply input for H driver 21 RED Video signal (R) input to panel 10 VSSG Negative power supply setting for V driver 22 BLUE Video signal (B) input to panel 11 TEST2 Test; no connection 23 RGT H shift register drive direction signal input 12 WIDE Pulse input for 16:9 mode 24 TESTR Panel test output; no connection Pin No. Symbol 1 TESTL 2 Description –5– Description ACX302AK Input Equivalent Circuits To prevent static charges, protective diodes are provided for each pin except the power supplies. In addition, protective resistors are added to all pins except the video signal input pins. All pins are connected to Vss with a high resistance of 1MΩ (typ.). The equivalent circuit of each input pin is shown below: (Resistor value: typ.) (1) RED, GREEN, BLUE, PSIG HVDD Input 1MΩ Signal line (2) HCK1, HCK2 HVDD HVDD H level shifter and shift register circuit HCK1 1MΩ HCK2 1MΩ (3) HST, WIDE, REF HVDD HVDD 350Ω 350Ω Level conversion circuit Input 1MΩ REF 1MΩ (4) RGT, REF HVDD HVDD 2kΩ 2kΩ Level conversion circuit Input 1MΩ REF 1MΩ (5) VST, VCK, EN, REF VVDD VVDD 800Ω 800Ω Level conversion circuit Input 1MΩ REF 1MΩ –6– ACX302AK (6) DWN, REF VVDD VVDD 2kΩ 2kΩ Level conversion circuit Input 1MΩ REF 1MΩ (7) VSSG HVDD Negative voltage generation circuit VSSG (8) COM Input LC 1MΩ (9) Cext/Rext HVDD H driver Cext/Rext 1MΩ (10) TEST1/TEST2 HVDD 350Ω 350Ω TEST1 TEST2 1MΩ 1MΩ (11) TESTL, TESTR TESTL TESTR –7– ACX302AK Clock Timing Conditions (VIH = 3.0V, HVDD = VVDD = 12V, Ta = 25°C) Symbol Item HST HCK VST VCK EN WIDE Min. Typ. Max. HST rise time trHst — — 30 HST fall time tfHst — — 30 HST data setup time tdHst 137 167 197 HST data hold time thHst –30 0 30 HCKn rise time trHckn — — 30 HCKn fall time HCK1∗5 fall to HCK2 rise time tfHckn — — 30 to1Hck –15 0 15 HCK1∗5 rise to HCK2 fall time to2Hck –15 0 15 VST rise time trVst — — 100 VST fall time tfVst — — 100 VST data setup time tdVst 30 32 34 VST data hold time thVst –34 –32 –30 VCK rise time trVckn — — 100 VCK fall time tfVckn — — 100 EN rise time trEn — — 100 EN fall time tfEn — — 100 EN rise to VCK rise/fall time tdEn 2400 2500 2600 EN pulse width twEn 5400 5500 5600 WIDE rise time trWide — — 100 WIDE fall time tfWide — — 100 WIDE (H) rise to VCK rise/fall time tdhWide 0.9 1.1 1.3 WIDE (H) pulse width twhWide 2.8 3.0 3.3 WIDE (V) pulse width twvWide 1928 1933 1938 WIDE (V) fall to EN rise time tov1Wide 25 32 — EN fall to WIDE (V) fall time tov2Wide 25 32 — ∗5 HCKn means HCK1 and HCK2. (fHCKn = 3.0MHz) –8– Unit ns µs ns µs ACX302AK Horizontal Standard Timing 5.0µs HST HCK1 HCK2 1.3µs FRP VCK 3µs 2.5µs EN WIDE∗6 1.1µs 1.9µs ∗6 WIDE represents every 1H pulse indicated on the horizontal timing. –9– ACX302AK <Horizontal Shift Register Driving Waveforms> Item HST rise time Symbol Waveform trHst 90% HST HST HST fall time tfHst HST data setup time tdHst Conditions 90% 10% 10% trHst tfHst • HCKn∗5 duty cycle 50% to1Hck = 0ns to2Hck = 0ns ∗7 HST 50% 50% 50% 50% HCK1 HST data hold time thHst thHst tdHst HCKn∗5 rise time trHckn ∗5 90% HCKn HCKn∗5 fall time • HCKn∗5 duty cycle 50% to1Hck = 0ns to2Hck = 0ns tdHst = 167ns thHst = 0ns 90% 10% tfHckn HCK HCK1 fall to HCK2 rise time • HCKn∗5 duty cycle 50% to1Hck = 0ns to2Hck = 0ns 10% trHckn tfHckn ∗7 to1Hck HCK1 50% 50% 50% • tdHst = 167ns thHst = 0ns 50% HCK2 HCK1 rise to HCK2 fall time to2Hck WIDE rise time trWide to2Hck to1Hck 90% 90% WIDE 10% WIDE fall time tfWide WIDE fall to VCK rise/fall time tdhWide trWide ∗6 WIDE VCK WIDE WIDE pulse width 10% twhWide tfWide 50% 50% 50% twWide tdWide ∗7 Definitions: The right-pointing arrow ( ) means +. The left-pointing arrow ( ) means –. The black dot at an arrow ( ) indicates the start of measurement. – 10 – ACX302AK Vertical Standard Timing NTSC 4:3 (in case of EVEN field) VST VCK FRP HST EN WIDE NTSC WIDE (in case of EVEN field) VST VCK FRP HST EN ∗8 WIDE ∗8 WIDE represents 1F period indicated on the vertical timing. – 11 – ACX302AK <Vertical Shift Register Driving Waveforms> Item VST rise time Symbol Waveform trVst 90% Conditions 90% VST 10% VST VST fall time tfVst VST data setup time tdVst 10% trVst tfVst ∗7 VST 50% 50% 50% 50% VCK VST data hold time VCK rise time thVst trVck VCK VCK VCK fall time tfVck EN rise time trEn tdVst thVst 90% 90% 10% 10% trVck tfVck 90% 90% • VCK duty cycle 50% to1Vck = 0ns to2Vck = 0ns 10% 10% EN fall time tfEn EN fall to VCK rise/fall time tdEn ∗7 VCK 50% 50% EN EN pulse width trEn tfEn twEn tdEn WIDE rise time trWide 50% twEn 90% 90% WIDE 10% ∗8 WIDE WIDE fall time tfWide WIDE pulse width twvWide 10% trWide WIDE tfWide 50% 50% twWide ∗7 WIDE fall to EN fall time tov1Wide trWide 50% WIDE EN 50% EN rise to WIDE fall time tov2Wide 50% to1Wide to2Wide – 12 – • VCK duty cycle 50% to1Vck = 0ns to2Vck = 0ns • VCK duty cycle 50% to1Vck = 0ns to2Vck = 0ns tdVst = 32µs thVst = –32µs EN EN • VCK duty cycle 50% to1Vck = 0ns to2Vck = 0ns ACX302AK Electrical Characteristics (Ta = 25°C, HVDD = 12.0V, VVDD = 12.0V, VIH = 3.0V, VREF = 1.5V) 1. Horizontal drivers Item Symbol Min. Typ. Max. Unit HCKn input pin capacitance CHckn — 80 95 pF HST input pin capacitance CHst — 30 45 pF Video signal input pin capacitance Csig — 270 310 pF Psig input pin capacitance (4:3 display) Cpsig — 16 20 nF Psig input pin capacitance (16:9 display) Cpsig — 45 50 nF Input pin current HCK1 I Hck1 –900 –300 — µA HCK1: actual driving HCK2 I Hck2 –900 –300 — µA HCK2: actual driving HST I Hst –300 –100 — µA HST = GND RGT I RGT –150 –50 — µA RGT = GND REF I REF –1200 –300 — µA REF = VIH/2 (Ta = 25°C) I H25 — 4.0 4.75 mA (Ta = 60°C) I H60 — — 6.00 mA Symbol Min. Typ. Max. Unit VCK input pin capacitance CVck — 10 15 pF VST input pin capacitance CVst — 10 15 pF Input pin current VCK I Vck –150 –50 — µA VCK = GND VST I Vst –150 –50 — µA VST = GND EN I En –150 –50 — µA EN = GND DWN I DWN –150 –50 — µA DWN = GND WIDE I WIDE –150 –50 — µA WIDE = GND Current consumption Conditions HCKn: HCK1, HCK2 (3.0MHz) 2. Vertical drivers Item Current consumption (Ta = 25°C) I V25 — 1.0 1.5 mA (Ta = 60°C) I V60 — — 2.0 mA Symbol Min. Typ. Max. Unit (Ta = 25°C) PWR25 — 60 75 mW (Ta = 60°C) PWR60 — — 96 mW Symbol Min. Typ. Max. Unit Rin 0.5 1 — MΩ 3. Total power consumption of the panel Item Total power consumption of the panel (NTSC) 4. Pin input resistance Item Pin – VSS input resistance – 13 – Conditions ACX302AK Electro-optical Characteristics (Ta = 25°C, NTSC mode) Item Symbol Contrast ratio 25°C CR25 60°C CR60 T Optical transmittance Measurement method 1 2 Min. Typ. Max. 100 200 — 100 200 — 7.7 8.2 — Unit — % X Rx 0.595 0.625 0.655 Y Ry 0.310 0.340 0.370 X Gx 0.245 0.275 0.305 Y Gy 0.580 0.610 0.640 X Bx 0.120 0.150 0.180 Y By 0.090 0.120 0.150 25°C V90-25 1.30 1.50 1.70 60°C V90-60 1.30 1.50 1.70 25°C V50-25 1.70 1.90 2.10 60°C V50-60 1.70 1.90 2.10 25°C V10-25 2.20 2.40 2.60 60°C V10-60 2.20 2.40 2.60 R–G V50RG –0.050 –0.080 –0.110 B–G V50BG 0.000 0.030 0.050 0°C ton0 — 40 55 25°C ton25 — 15 25 0°C toff0 — 140 180 25°C toff25 — 50 75 Flicker 60°C F 7 — –60 –30 dB Image retention time 1 min. YT1 8 — — 10 s CR ≥ 10 θT θB θL θR 9 35 50 45 45 45 60 55 55 — Degree (°) Surface reflection ratio θ = 0° Rf 10 — 0.9 1.5 % Cross talk 25°C CTK 11 — 1.5 % R Chromaticity G B V90 V-T characteristics V50 V10 Half tone color reproduction range ON time Response time OFF time Viewing angle range 3 – 14 – 4 5 6 CIE standards V V ms ACX302AK <Electro-optical Characteristics Measurement> Basic measurement conditions (1) Driving voltage HVDD = 12.0V, VVDD = 12.0V, VIH = 3.0V, VREF = 1.5V VVC = 5.5V, VCOM = 5.2V, Vpsig = 5.5 ± 2.5V (2) Measurement temperature 25°C unless otherwise specified. (3) Measurement point One point in the center of the screen unless otherwise specified. (4) Measurement systems Three types of measurement systems are used as shown below. (5) R, G and B input signal voltage Vsig Vsig = 5.5 ± VAC [V] (VAC: signal amplitude) Surface A∗ Backlight ∗ Measurement system I Luminance Meter Measurement Equipment 3.5mm LCD panel ∗ Measurement system II Optical fiber Light receptor lens Light Detector Surface A∗ Measurement Equipment LCD panel Drive Circuit Light Source ∗ Measurement system III Light Source Optical fiber Spectroscope Surface A∗ ∗ Surface A: See the Package Outline. 1. Contrast Ratio Contrast ratio (CR) is given by the following formula. CR = L (White)/L (Black) L (White): Surface luminance of the TFT-LCD panel at the input signal amplitude VAC = 0.5V. L (Black): Surface luminance of the panel at VAC = 4.0V. Both luminosities are measured by System I. – 15 – ACX302AK 2. Optical Transmittance Optical transmittance (T) is given by the following formula. T = L (White)/Luminance of Backlight × 100 [%] L (White) is the same expression as defined in the "Contrast Ratio" section. Optical transmittance is measured by System I. 3. Chromaticity Chromaticity of the panels is measured by System I. Raster modes of each color are defined by the representations at the input signal amplitude conditions shown in the table below. System I uses x and y of the CIE standards as the chromaticity here. Signal amplitudes (VAC) supplied to each input Raster R input G input B input R 0.5 4.0 4.0 G 4.0 0.5 4.0 B 4.0 4.0 0.5 W 0.0 0.0 0.0 4. V-T Characteristics V-T characteristics, or the relationship between signal amplitude and the transmittance of the panel, are measured by System II by inputting the same signal amplitude VAC to each input pin. V90, V50, and V10 correspond to the voltages which define 90%, 50%, and 10% of transmittance respectively. Transmittance [%] (Unit: V) 90 50 10 V90 V50 V10 VAC – Signal amplitude [V] – 16 – 100 Transmittance [%] 5. Half Tone Color Reproduction Range The half tone color reproduction range of LCD panels is characterized by the differences between the V-T characteristics of R, G and B. The differences of these V-T characteristics are measured by System II. System II defines signal voltages of each R, G and B raster mode which correspond to 50% of transmittance, V50R, V50G and V50B, respectively. V50RG and V50BG, that is to say the differences between V50R and V50G and between V50B and V50G, are given by the following formulas respectively. V50RG = V50R – V50G V50BG = V50B – V50G V50RG V50BG 50 R raster G raster B raster 0 V50R V50B V50G VAC – Signal amplitude [V] ACX302AK 6. Response Time Response times ton and toff are measured by System II by applying the input signal voltages in the figure to the right to each input pin. These times are defined by the following formulas. ton = t1 – tON toff = t2 – tOFF t1: time which gives 10% transmittance of the panel. t2: time which gives 90% transmittance of the panel. Input signal voltage (Waveform applied to measured pixels) 4.0V 0.5V 5.5V 0V Optical transmittance output waveform 100% 90% The relationships between t1, t2, tON and tOFF are shown in the figure to the right. 10% 0% tON t1 ton tOFF t2 toff 7. Flicker Flicker (F) is given by the following formula. DC and AC components (NTSC: 30Hz, rms; PAL: 25Hz, rms) of the panel output signal for gray raster* mode are measured by a DC voltmeter and a spectrum analyzer in System II. F (dB) = 20 log {AC component/DC component} ∗ R, G, B input signal voltage for gray raster mode is given by Vsig = 5.5 ± V50 (V) where: V50 is the signal amplitude which gives 50% of transmittance in V-T curve. 8. Image Retention Time Image retention time is given by the following procedures. Apply the monoscope pattern∗ to the LCD panel for 1 minute and then change to a gray scale signal (Vsig = 5.5 ± VAC (V); VAC = 3 to 4V). Judging by sight at the VAC that holds the maximum image retention, measure the time for the residual image to disappear. ∗ Monoscope pattern input conditions Vsig = 5.5 ± 4.0 or 5.5 ± 2.0 [V] (shown in the figure to the right) Vcom = 5.20V Black level White level 4.0V 2.0V 5.5V 2.0V 4.0V 0V Vsig waveform – 17 – ACX302AK 9. Definition of Viewing Angle Range Viewing angle range is measured by System I. The contrast ratio (CR) is measured at the angles defined in the figure to the right and the range where CR ≥ 10 is taken as the viewing angle range. Measure with surface A∗ facing upwards. ∗ Surface A: See the Package Outline. Normal (θ = 0°) θB θT θL Left θR Top Bottom Right Surface A 10. Surface Reflection Ratio Surface reflection ratio (Rf) is given by the following formula. Rf = Reflected optical luminance of the panel surface A∗/Reflected optical luminance of Al (wafer) × 100 [%] The incident and reflected angles of light are both 0°. Both luminosities are measured by System III. ∗ Surface A: See the Package Outline. 11. Cross Talk Cross talk is determined by the luminance differences between adjacent areas represented by Wi' and Wi (i = 1 to 4) around the black window (Vsig = 4.0V/1V). W1 W1' Cross talk value CTK = W2 W4 W2' W4' Wi' – Wi Wi × 100 [%] W3 W3' 12. Measurement Backlight Specifications Optical characteristics Item Standard Average luminance of effective illuminating surface 2,700 ± 300 Color temperature (reference value) 8,800 Chromaticity coordinates x: 0.285 ± 0.01 y: 0.303 ± 0.01 Unit Remarks cd/m2 Ta = 25 ± 2°C, at dimmer = max. K – 18 – Ta = 25 ± 2°C, at dimmer = max. ACX302AK Description of Operation 1. Color Coding The color filters are coded in a delta arrangement. The shaded area is used for the dark border around the display. Gate SW Gate SW Gate SW Gate SW Gate SW 1 Gate SW G R B R B G G R G B R B B G R G B 880 884 – 19 – B G R G B R G B R G B R G R B G B R G B Active area R R G R B G B R G R B G B G R B R B G R G R B G B G R B R B G R G R B G B G R B R G B G R B 2 B G R G R B R B R G B R G B R B R G G R G B R R G B R G B R G R G B R B G B R B R G G R G B R 2 230 R B R B 228 G 1 R ACX302AK 2. Description of LCD Panel Operations • A vertical driver, which consists of vertical shift registers, enable-gates and buffers, applies a selected pulse to each of 228 line electrodes sequentially one line electrode at a time in a single horizontal scanning period. • The selected pulse is output when the enable pin goes to high level. PAL signal pulse elimination display and 16:9 mode pulse elimination display are possible by using the enable pin and simultaneously controlling VCK. • A horizontal driver, which consists of horizontal shift registers, gates and CMOS sample-and-hold circuitry, applies selected pulses to each of 880 signal electrodes sequentially in a single horizontal scanning period. These pulses are used to supply the sampled video signal to the row signal lines. • The scanning direction of the horizontal shift registers can be switched with the RGT pin. The scanning direction is left to right (right scan) for RGT pin at high level (2.6 to 5.5V), and right to left (left scan) for RGT pin at low level (0V). In addition, the scanning direction of the vertical shift registers can be switched with the DWN pin. The scanning direction is top to bottom for DWN pin at high level (2.6 to 5.5V), and bottom to top for DWN pin at low level (0V). (These scanning directions are from a front view.) • The vertical and horizontal drivers address one pixel, and then thin film transistors (TFTs; two TFTs for one pixel) turn on to apply a video signal to the pixel. The same procedures lead to the entire 228 × 880 pixels to display a picture in a single vertical scanning period. • Pixel dots are arranged in a delta arrangement, where sets of RGB pixels are positioned shifted by 1.5 dots against adjacent horizontal lines. The horizontal driver output pulse must be shifted by 1.5 dots for each horizontal line against the horizontal sync signal to apply a video signal to each pixel properly. • The video signal should be input with the polarity-inverted every horizontal cycle. • The relationships between the vertical shift register start pulse VST and the vertical display period, and between the horizontal shift register start pulse HST and the horizontal display period are shown below for top to bottom and left to right scan. (1) Vertical display period (DWN: high level) VD VST VCK 1 2 227 228 Vertical display period 228H (14.5ms) (2) Vertical display period (DWN: low level) VD VST 1 VCK 2 227 228 Vertical display period 228H (14.5ms) (3) Horizontal display period (RGT: high level) BLK HST 294 HCK1 1 2 3 293 295 Horizontal display period (48.9µs) HCK2 – 20 – ACX302AK 3. RGB Simultaneous Sampling The horizontal driver samples R, G and B video signal simultaneously, which requires phase matching between the R, G and B signals to prevent the horizontal resolution from deteriorating. Thus phase matching by an external signal delay circuit is needed before applying the video signal to the LCD panel. Two methods are applied for the delaying procedure: Sample-and-hold and Delay circuits. These two block diagrams are as follows. The ACX302AK has a right/left inversion function. The following phase relationship diagram indicates the phase setting for right scan (RGT = high level). For left scan (RGT = low level), the phase setting should be inverted for the B and G signals. B S/H S/H CKB CKG R S/H S/H CKR CKG G S/H AC Amp 22 BLUE AC Amp 21 RED AC Amp 20 GREEN ACX302AK (1) Sample-and-hold (right scan) CKG <Phase relationships of delaying sample-and-hold pulses> (right scan) HCKn CKB CKR CKG B R Delay Delay AC Amp 22 BLUE Delay AC Amp 21 RED AC Amp 20 GREEN G – 21 – ACX302AK (2) Delay element (right scan) ACX302AK System Configuration +12.0V +12.0V +3.0V 10kΩ PSIG Y/color difference RED R/G/B Cext/Rext Cext∗ GREEN BLUE ∗ See page 3 for the value setting. COM/CS HST HCK1 CXA3268AR HCK2 LCD Panel ACX302AK VST Serial data VCK DWN EN RGT Use a Zener voltage of 2.7V. (RD2.7UM is recommended.) REF WIDE VSSG 1µF Control Circuit – 22 – ACX302AK Notes on Handling (1) Static charge prevention Be sure to take the following protective measures. TFT-LCD panels are easily damaged by static charges. a) Use non-chargeable gloves, or simply use bare hands. b) Use an earth-band when handling. c) Do not touch any electrodes of a panel. d) Wear non-chargeable clothes and conductive shoes. e) Install grounded conductive mats on the working floor and working table. f) Keep panels away from any charged materials. g) Use ionized air to discharge the panels. (2) Protection from dust and dirt a) Operate in a clean environment. b) Do not touch the polarizer surface. The surface is easily scratched. When cleaning, use a clean-room wiper with isopropyl alcohol. Be careful not to leave stains on the surface. c) Use ionized air to blow dust off the panel. (3) Other handling precautions a) Do not twist or bend the flexible PC board especially at the connecting region because the board is easily deformed. b) Do not drop the panel. c) Do not twist or bend the panel or panel frame. d) Keep the panel away from heat sources. e) Do not dampen the panel with water or other solvents. f) Avoid storing or using the panel at high temperatures or high humidity, as this may result in panel damage. – 23 – 2.2 31.08 Note1. Tolerance with no indicate(±0.2) 2. SONY logotype 3. Label is stuck hear 12.8 ±0.5 Note 2 2 1 (2.75) Mass: Approximately 25g Center (reference) 70.4(Active area) Thickness of the connector Front view (39.9) (37.15) 74.3(Window) 73±0.5 (Polarizer) 37.15 38.9 52.725(Active area) 78.8 (3.35) (0.5) Pin24 63.3 Unit: mm 12.5 ±0.05 32 0.3 ±0.05 (32.22) 1.75 28.35 (28.3) (Polarizer) 55.4 ±0.5 30 ±0.5 0.35 ±0.03 72±0.5 Electrode Enlarged(Back) 36.55 0.5 Pin1 Center (Reference) (Polarizer) P : 0.5±0.02×23=11.5±0.03 Rear view (36.55) 73.1(Window) Note 3 2.35 (Polarizer) 54.4 ±0.5 3 4 1FPC 2 Reinforcing board 3 Polarizer 4 Shield case(Front) 5Shield case(Rear) 6 Double coated adhesive tape 3.33 55.5(Window) 2.73 28.35 (28.35) (3.87) – 24 – (4.47) Package Outline 6 3 6 5 ACX302AK 56.7(Window)