ETC AM-030C1-433AMS-105C3A-433

REMOTE RECEIVER DECODER
RADIO / INFRA-RED / PAGER
zzz-105Cnd-xxx
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
GENERAL PURPOSE DECODER; RADIO, INFRA-RED,
PAGER
4 RELAY CHANNELS – EXPANDABLE TO 15
RADIO FREQS; 173 / 433 / 458 / 868 MHz
IP65 RATED ENCLOSURE
EASY INSTALLATION VIA SCREW TERMINALS
230VAC OR 12-30VDC SUPPLY
15 CMOS/TTL CHANNEL O/P's
LED INDICATION OF EACH RELAY OUTPUT.
MOMENTARY OR LATCHING OUTPUTS
1 TIMED OUTPUT ADJUSTABLE 0 To 255 secs
RELAY CONTACTS 2.5A @ 230VAC
REQUIRES NO RADIO LICENCE
DESCRIPTION
A general-purpose Rx decoder which may operate as radio, infra-red or pager system. The unit is supplied in a
tough ABS enclosure with IP65 rating, complete and ready to operate.
As a pager system (using Globemaster Module G100UK), the unit is a stand-alone pager controller. As a radio
or infrared Rx decoder, the system may be supplied with one of several modules to enable the user to choose the
optimum frequency modulation and range.
The Rx decoder has a self-learning feature, which enables it to learn the signature code of up to 50 individual RF
Solutions KEELOQ Tx encoders.
Connections to the power supply and relay outputs are provided through screw terminals (these are the only
connections required). The output relays are rated 2.5A @ 240VAC operating as either momentary of latched
operation. An additional ”Low battery” LED and relay is also provided to indicate that the Tx encoder battery
voltage is low.
Output 1 has a variable time feature, which may be adjusted to give a timed output (upto 4 minutes). A further 15
momentary digital channels are also provided for expansion using the ‘115’ Expander (See datasheet DS000115).
Performance Table
Modulation
RF Frequency
Transmit Output Power
Range *
(MHz)
(mW)
(m)
Infra-Red
-
-
20
FM
173
10
1000
AM
433
10
45
FM
433
10
300
FM
458
500
3,000
See DS000100
The UK
Globemaster
*NOTE: Range figure is a typical indication only. Range depends on many factors, e.g. antennae, interference, and environmental conditions.
DS000105
Ver 1.4 Aug 99
©1999 Reg. No. 227 4001, ENGLAND
Page 1
REMOTE RECEIVER DECODER
RADIO / INFRA-RED / PAGER
zzz-105Cnd-xxx
RX DECODER CONNECTIONS
ANT
F1
D8
D7
D10
D9
POWERLED
J3
T1
BATT LOW LED
LEARN
SWITCH
INFRA-RED
HEADER
MAINS
TRANSFORMER
RF RECEIVER / PAGER
T2
E
J4
J7
J5
DIGITAL OUTPUT 15
J6
0V
+12V
VR1
RLY
9
1 TO 15
DIGITAL
OUTPUTS
240VAC
Mains
N
100nF
SW1
J2 J1
LINKS
L
C9
LEARNLED
RLY
5
RLY 1
J9
RLY
6
RLY 2
J10
DIGITAL OUTPUT 1
N/OCOMMN/C
N/OCOMM N/C
GND
LOWBATT
O/P1
CH4 CH3 CH2 CH1
LEDCHANNELINDICATORS
RLY
7
RLY 3
J11
RLY
8
RLY 4
DC
The decoder
requires
either a
single
12-30 VDC
supply or
240VAC
mains.
NOT BOTH!
J12
N/OCOMMN/C
N/OCOMMN/C
N/OCOMMN/C
O/P2
O/P3
O/P4
WARNING!
The unit is designed to be a fixed installation, which may be connected to a mains supply. Before removing the
cover ensure that the mains input supply is removed.
Any operation of the product that involves removal of the front cover should only be carried out by a competent
person or qualified electrician.
CONFIGURING THE OUTPUTS (Jumper Links J1, J2)
These links configure the operation of the digital outputs according to the table below.
NOTE: The link status is read only on power up, after changing the links please remember to remove and reapply power.
J1
Open
Open
Connected
Connected
Latch:
J2
Open
Connected
Open
Connected
O/P 1
Latch
Timed
Latch
Timed
O/P 2
Latch
Momentary
Latch
Momentary
O/P 3
Latch
Momentary
Momentary
Latch
O/P 4
Latch
Momentary
Momentary
Latch
The relay operates until the next valid transmission is received
Momentary: The relay operates momentarily (approx. 600mSecs) or for as long as the Tx encoder switch is
held on.
DS000105
Ver 1.4 Aug 99
©1999 Reg. No. 227 4001, ENGLAND
Page 2
REMOTE RECEIVER DECODER
RADIO / INFRA-RED / PAGER
zzz-105Cnd-xxx
RELAY OUTPUTS
The system is supplied with relay(s) type OMRON GL5114P or equivalent. An alternative which may be fitted is
BT47W/6.
Notes:
1. Only one relay per output channel must be fitted.
2. The user must ensure that the load connected does not overload the relay!
3. The low battery relay is not mains rated
Relay Type
OMRON G5L114P
BT47W/6
1
RLY 1
RLY 5
2
RLY 2
RLY 6
Output Channel
3
RLY 3
RLY 7
4
RLY 4
RLY 8
Low Battery
RLY9
TIMED OUTPUT
Output 1 has a variable timed output controlled by VR1. This may be adjusted from no delay to a maximum of 4
minutes 15 seconds.
Turning VR1 clockwise increases the output delay.
LOW BATTERY RELAY
The low battery feature informs the user that the Tx encoder used has a low voltage battery.
The LOW BATT channel operates if the Rx decoder has received a transmitted signal with low voltage signal
present. This will continue to operate until a transmitted signal without the low voltage signal has been received.
NOTE: the LOW BATT relay is type BT47W/6.
Expanding the system to 15 Relay outputs
A relay expansion unit is available to connect directly to the ‘105’ Series Remote Decoder via single connector
(16 way screw terminal) and provides 15 momentary relay output channels, mapped directly from the ‘105 ‘ digital
outputs.
An additional relay (channel 16) is also provided, this operates if any of relay channels 1 to 15 are operated
(Wired OR configuration). Operation of each relay is indicated by an LED
The system may be supplied as a PCB or in an IP65 rated enclosure and requires either 240Vac or 12-30Vdc
supply. The unit is easy to install; all connections are via screw terminals.
For further information please see Datasheet DS000115.
LEARNING A NEW TX ENCODER
1.
2.
3.
4.
5.
Press the programming switch on the Rx decoder once (SW1)
The learn LED will illuminate
Press one of the switches on the Tx encoder once, learn LED on the Rx decoder will extinguish
Press one of the switches on the Tx encoder again, learn LED will flash
When the learn LED has stopped flashing this Tx encoder will now operate the system
ERASING EXISTING TX ENCODER
1.
To completely erase the Tx encoders, press SW1 on the Rx decoder for 10 seconds.
2.
The learn LED will turn off after the 10 seconds to indicate the Tx encoder(s) have been erased
NOTE: You can not erase individual Tx encoders
DS000105
Ver 1.4 Aug 99
©1999 Reg. No. 227 4001, ENGLAND
Page 3
REMOTE RECEIVER DECODER
RADIO / INFRA-RED / PAGER
zzz-105Cnd-xxx
APPLICATION NOTE: IMPLEMENTING 15 SWITCH REMOTE CONTROL SYSTEM
It is possible to implement a 15 channel remote control system by using the R.F. Solutions RF103 or RF107 Tx
encoders and the digital outputs on connector J5 of the RF105 Rx decoder.
Encoder Connections: The following diagram shows how to connect 15 switches to connector J2 on the RF103
and RF107 Tx encoders. Note that diodes D2-D29 must be fitted.
+5V (PINS 16-20)
+5V (PINS 16-20)
SW1
SW9
J2
PIN 1
J2
PIN 9
SW2
SW10
PIN 2
PIN 10
SW3
SW11
PIN 3
PIN 11
SW4
SW12
PIN 4
PIN 12
SW5
SW13
PIN 5
PIN 13
SW6
SW14
PIN 6
PIN 14
SW7
SW15
PIN 7
PIN 15
SW8
PIN 8
Switch Connections For RF103
Decoder Connections: The digital outputs are located on connector J5. These are momentary CMOS/TTL
compatible outputs.
The decoder output channels on J5 are directly linked to inputs on the encoder J2.
The decoder output channels on J5 may also be operated from the four switches on the Tx encoder RF102 and
RF103 using binary coded decimal inputs as shown below.
TX Encoder I/P
Digital Inputs (J2)
SW4
SW3
1
0
0
2
0
0
3
0
0
4
0
1
5
0
1
6
0
1
7
0
1
8
1
0
9
1
0
10
1
0
11
1
0
12
1
1
13
1
1
14
1
1
15
1
1
DS000105
Ver 1.4 Aug 99
SW2
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
SW1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
RX Decoder O/P
Digital Output (J5)
Output channel
1
1
2
2
3
2,1
4
3
5
3,1
6
3,2
7
3,2,1
8
4
9
4,1
10
4,2
11
4,2,1
12
4,3
13
4,3,1
14
4,3,2
15
4,3,2,1
©1999 Reg. No. 227 4001, ENGLAND
Page 4
REMOTE RECEIVER DECODER
RADIO / INFRA-RED / PAGER
zzz-105Cnd-xxx
The following diagram shows an example of how to connect the digital outputs on connector J5 to drive external
relays.
+12V
+12V
C1
NO
COM
C2
NC
G5L114P
C1
C1
NO
COM
C2
NC
G5L114P
C1
C1
NO
COM
C2
NC
G5L114P
C1
C1
C1
NO
COM
C2
NC
G5L114P
J5
Dig.
Dig.
Dig.
Dig.
Dig.
Dig.
Dig.
Dig.
Output
Output
Output
Output
Output
Output
Output
Output
1
2
3
4
5
6
7
8
I1
I2
I3
I4
I5
I6
I7
I8
GND
O1
O2
O3
O4
O5
O6
O7
O8
V+
ULN2803
NO
COM
C2
NC
G5L114P
C2
NO
COM
NC
G5L114P
NO
COM
C2
NC
G5L114P
NO
COM
C2
NC
G5L114P
Relay Buffering Circuit for RF105 Digital Outputs
DS000105
Ver 1.4 Aug 99
©1999 Reg. No. 227 4001, ENGLAND
Page 5
REMOTE RECEIVER DECODER
RADIO / INFRA-RED / PAGER
zzz-105Cnd-xxx
TECHNICAL SPECIFICATIONS
Storage Temperature; -10 to +70o Celsius.
Operating Temperature; 0 to +55o Celsius.
Dimensions:
Enclosure : 190 x 120 x 60 mm
PCB: 174 x 106mm
ELECTRICAL CHARACTERISTICS
Supply Voltage
Supply Current :
Quiescent
Time from Encoder Switch depressed to relay output
All Relays operating
Relay Rating (240Vac) RLY1-4
Relay Rating RLY5-9
Relay Rating RLY5-9
MIN
11.0
TYPICAL
16.0
MAX
30.0
25
250
400
2.5
5
2
50
DIMENSION
V
mA
mSecs
mA
A
A @12Vdc
Vdc @0.5A
Part Numbering
The Rx decoder part number is made up as follows
zzz-105Cnd-xxx
Character
zzz
Meaning
Modulation
105
C
n
d
Product Identifier
Supplied in Enclosure
No of Relays
Power Supply
xxx
Frequency of operation
Possible values
AM,
FM
IR
G100
C
1, 4
D
A
173, 433,458,868
Notes
AM-Superegenerative
FM Superhetrodyne
Infra-Red
Globemaster
C = in enclosure
D = 12-30Vdc only
A = 240Vac or 12-30Vdc
Frequency
Examples,
AM-1054D-433 FM-1051A-458 -
is an AM SuperRegen Rx decoder with 4 relays, DC power supply, operating at 433MHz.
is an FM Superhetrodyne Rx decoder with 1 relay, mains power supply, operating at 458MHz.
For more information or general enquiries, please contact
R. F. Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
South Street,
Lewes,
E Sussex, BN8 6JL. England
Tel +44 (0)1273 898 000
Email [email protected]
Fax +44 (0)1273 480 661
http://www.rfsolutions.co.uk
RF Solutions is a member of the Low Power Radio Association
All Trademarks acknowledged and remain the property of the respected owners
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.
Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS000105
Ver 1.4 Aug 99
©1999 Reg. No. 227 4001, ENGLAND
Page 6