REMOTE RECEIVER DECODER RADIO / INFRA-RED / PAGER zzz-105Cnd-xxx FEATURES • • • • • • • • • • • • GENERAL PURPOSE DECODER; RADIO, INFRA-RED, PAGER 4 RELAY CHANNELS – EXPANDABLE TO 15 RADIO FREQS; 173 / 433 / 458 / 868 MHz IP65 RATED ENCLOSURE EASY INSTALLATION VIA SCREW TERMINALS 230VAC OR 12-30VDC SUPPLY 15 CMOS/TTL CHANNEL O/P's LED INDICATION OF EACH RELAY OUTPUT. MOMENTARY OR LATCHING OUTPUTS 1 TIMED OUTPUT ADJUSTABLE 0 To 255 secs RELAY CONTACTS 2.5A @ 230VAC REQUIRES NO RADIO LICENCE DESCRIPTION A general-purpose Rx decoder which may operate as radio, infra-red or pager system. The unit is supplied in a tough ABS enclosure with IP65 rating, complete and ready to operate. As a pager system (using Globemaster Module G100UK), the unit is a stand-alone pager controller. As a radio or infrared Rx decoder, the system may be supplied with one of several modules to enable the user to choose the optimum frequency modulation and range. The Rx decoder has a self-learning feature, which enables it to learn the signature code of up to 50 individual RF Solutions KEELOQ Tx encoders. Connections to the power supply and relay outputs are provided through screw terminals (these are the only connections required). The output relays are rated 2.5A @ 240VAC operating as either momentary of latched operation. An additional ”Low battery” LED and relay is also provided to indicate that the Tx encoder battery voltage is low. Output 1 has a variable time feature, which may be adjusted to give a timed output (upto 4 minutes). A further 15 momentary digital channels are also provided for expansion using the ‘115’ Expander (See datasheet DS000115). Performance Table Modulation RF Frequency Transmit Output Power Range * (MHz) (mW) (m) Infra-Red - - 20 FM 173 10 1000 AM 433 10 45 FM 433 10 300 FM 458 500 3,000 See DS000100 The UK Globemaster *NOTE: Range figure is a typical indication only. Range depends on many factors, e.g. antennae, interference, and environmental conditions. DS000105 Ver 1.4 Aug 99 ©1999 Reg. No. 227 4001, ENGLAND Page 1 REMOTE RECEIVER DECODER RADIO / INFRA-RED / PAGER zzz-105Cnd-xxx RX DECODER CONNECTIONS ANT F1 D8 D7 D10 D9 POWERLED J3 T1 BATT LOW LED LEARN SWITCH INFRA-RED HEADER MAINS TRANSFORMER RF RECEIVER / PAGER T2 E J4 J7 J5 DIGITAL OUTPUT 15 J6 0V +12V VR1 RLY 9 1 TO 15 DIGITAL OUTPUTS 240VAC Mains N 100nF SW1 J2 J1 LINKS L C9 LEARNLED RLY 5 RLY 1 J9 RLY 6 RLY 2 J10 DIGITAL OUTPUT 1 N/OCOMMN/C N/OCOMM N/C GND LOWBATT O/P1 CH4 CH3 CH2 CH1 LEDCHANNELINDICATORS RLY 7 RLY 3 J11 RLY 8 RLY 4 DC The decoder requires either a single 12-30 VDC supply or 240VAC mains. NOT BOTH! J12 N/OCOMMN/C N/OCOMMN/C N/OCOMMN/C O/P2 O/P3 O/P4 WARNING! The unit is designed to be a fixed installation, which may be connected to a mains supply. Before removing the cover ensure that the mains input supply is removed. Any operation of the product that involves removal of the front cover should only be carried out by a competent person or qualified electrician. CONFIGURING THE OUTPUTS (Jumper Links J1, J2) These links configure the operation of the digital outputs according to the table below. NOTE: The link status is read only on power up, after changing the links please remember to remove and reapply power. J1 Open Open Connected Connected Latch: J2 Open Connected Open Connected O/P 1 Latch Timed Latch Timed O/P 2 Latch Momentary Latch Momentary O/P 3 Latch Momentary Momentary Latch O/P 4 Latch Momentary Momentary Latch The relay operates until the next valid transmission is received Momentary: The relay operates momentarily (approx. 600mSecs) or for as long as the Tx encoder switch is held on. DS000105 Ver 1.4 Aug 99 ©1999 Reg. No. 227 4001, ENGLAND Page 2 REMOTE RECEIVER DECODER RADIO / INFRA-RED / PAGER zzz-105Cnd-xxx RELAY OUTPUTS The system is supplied with relay(s) type OMRON GL5114P or equivalent. An alternative which may be fitted is BT47W/6. Notes: 1. Only one relay per output channel must be fitted. 2. The user must ensure that the load connected does not overload the relay! 3. The low battery relay is not mains rated Relay Type OMRON G5L114P BT47W/6 1 RLY 1 RLY 5 2 RLY 2 RLY 6 Output Channel 3 RLY 3 RLY 7 4 RLY 4 RLY 8 Low Battery RLY9 TIMED OUTPUT Output 1 has a variable timed output controlled by VR1. This may be adjusted from no delay to a maximum of 4 minutes 15 seconds. Turning VR1 clockwise increases the output delay. LOW BATTERY RELAY The low battery feature informs the user that the Tx encoder used has a low voltage battery. The LOW BATT channel operates if the Rx decoder has received a transmitted signal with low voltage signal present. This will continue to operate until a transmitted signal without the low voltage signal has been received. NOTE: the LOW BATT relay is type BT47W/6. Expanding the system to 15 Relay outputs A relay expansion unit is available to connect directly to the ‘105’ Series Remote Decoder via single connector (16 way screw terminal) and provides 15 momentary relay output channels, mapped directly from the ‘105 ‘ digital outputs. An additional relay (channel 16) is also provided, this operates if any of relay channels 1 to 15 are operated (Wired OR configuration). Operation of each relay is indicated by an LED The system may be supplied as a PCB or in an IP65 rated enclosure and requires either 240Vac or 12-30Vdc supply. The unit is easy to install; all connections are via screw terminals. For further information please see Datasheet DS000115. LEARNING A NEW TX ENCODER 1. 2. 3. 4. 5. Press the programming switch on the Rx decoder once (SW1) The learn LED will illuminate Press one of the switches on the Tx encoder once, learn LED on the Rx decoder will extinguish Press one of the switches on the Tx encoder again, learn LED will flash When the learn LED has stopped flashing this Tx encoder will now operate the system ERASING EXISTING TX ENCODER 1. To completely erase the Tx encoders, press SW1 on the Rx decoder for 10 seconds. 2. The learn LED will turn off after the 10 seconds to indicate the Tx encoder(s) have been erased NOTE: You can not erase individual Tx encoders DS000105 Ver 1.4 Aug 99 ©1999 Reg. No. 227 4001, ENGLAND Page 3 REMOTE RECEIVER DECODER RADIO / INFRA-RED / PAGER zzz-105Cnd-xxx APPLICATION NOTE: IMPLEMENTING 15 SWITCH REMOTE CONTROL SYSTEM It is possible to implement a 15 channel remote control system by using the R.F. Solutions RF103 or RF107 Tx encoders and the digital outputs on connector J5 of the RF105 Rx decoder. Encoder Connections: The following diagram shows how to connect 15 switches to connector J2 on the RF103 and RF107 Tx encoders. Note that diodes D2-D29 must be fitted. +5V (PINS 16-20) +5V (PINS 16-20) SW1 SW9 J2 PIN 1 J2 PIN 9 SW2 SW10 PIN 2 PIN 10 SW3 SW11 PIN 3 PIN 11 SW4 SW12 PIN 4 PIN 12 SW5 SW13 PIN 5 PIN 13 SW6 SW14 PIN 6 PIN 14 SW7 SW15 PIN 7 PIN 15 SW8 PIN 8 Switch Connections For RF103 Decoder Connections: The digital outputs are located on connector J5. These are momentary CMOS/TTL compatible outputs. The decoder output channels on J5 are directly linked to inputs on the encoder J2. The decoder output channels on J5 may also be operated from the four switches on the Tx encoder RF102 and RF103 using binary coded decimal inputs as shown below. TX Encoder I/P Digital Inputs (J2) SW4 SW3 1 0 0 2 0 0 3 0 0 4 0 1 5 0 1 6 0 1 7 0 1 8 1 0 9 1 0 10 1 0 11 1 0 12 1 1 13 1 1 14 1 1 15 1 1 DS000105 Ver 1.4 Aug 99 SW2 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 SW1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 RX Decoder O/P Digital Output (J5) Output channel 1 1 2 2 3 2,1 4 3 5 3,1 6 3,2 7 3,2,1 8 4 9 4,1 10 4,2 11 4,2,1 12 4,3 13 4,3,1 14 4,3,2 15 4,3,2,1 ©1999 Reg. No. 227 4001, ENGLAND Page 4 REMOTE RECEIVER DECODER RADIO / INFRA-RED / PAGER zzz-105Cnd-xxx The following diagram shows an example of how to connect the digital outputs on connector J5 to drive external relays. +12V +12V C1 NO COM C2 NC G5L114P C1 C1 NO COM C2 NC G5L114P C1 C1 NO COM C2 NC G5L114P C1 C1 C1 NO COM C2 NC G5L114P J5 Dig. Dig. Dig. Dig. Dig. Dig. Dig. Dig. Output Output Output Output Output Output Output Output 1 2 3 4 5 6 7 8 I1 I2 I3 I4 I5 I6 I7 I8 GND O1 O2 O3 O4 O5 O6 O7 O8 V+ ULN2803 NO COM C2 NC G5L114P C2 NO COM NC G5L114P NO COM C2 NC G5L114P NO COM C2 NC G5L114P Relay Buffering Circuit for RF105 Digital Outputs DS000105 Ver 1.4 Aug 99 ©1999 Reg. No. 227 4001, ENGLAND Page 5 REMOTE RECEIVER DECODER RADIO / INFRA-RED / PAGER zzz-105Cnd-xxx TECHNICAL SPECIFICATIONS Storage Temperature; -10 to +70o Celsius. Operating Temperature; 0 to +55o Celsius. Dimensions: Enclosure : 190 x 120 x 60 mm PCB: 174 x 106mm ELECTRICAL CHARACTERISTICS Supply Voltage Supply Current : Quiescent Time from Encoder Switch depressed to relay output All Relays operating Relay Rating (240Vac) RLY1-4 Relay Rating RLY5-9 Relay Rating RLY5-9 MIN 11.0 TYPICAL 16.0 MAX 30.0 25 250 400 2.5 5 2 50 DIMENSION V mA mSecs mA A A @12Vdc Vdc @0.5A Part Numbering The Rx decoder part number is made up as follows zzz-105Cnd-xxx Character zzz Meaning Modulation 105 C n d Product Identifier Supplied in Enclosure No of Relays Power Supply xxx Frequency of operation Possible values AM, FM IR G100 C 1, 4 D A 173, 433,458,868 Notes AM-Superegenerative FM Superhetrodyne Infra-Red Globemaster C = in enclosure D = 12-30Vdc only A = 240Vac or 12-30Vdc Frequency Examples, AM-1054D-433 FM-1051A-458 - is an AM SuperRegen Rx decoder with 4 relays, DC power supply, operating at 433MHz. is an FM Superhetrodyne Rx decoder with 1 relay, mains power supply, operating at 458MHz. For more information or general enquiries, please contact R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E Sussex, BN8 6JL. England Tel +44 (0)1273 898 000 Email [email protected] Fax +44 (0)1273 480 661 http://www.rfsolutions.co.uk RF Solutions is a member of the Low Power Radio Association All Trademarks acknowledged and remain the property of the respected owners Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd. DS000105 Ver 1.4 Aug 99 ©1999 Reg. No. 227 4001, ENGLAND Page 6