TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Radiation Lot Acceptance Testing (RLAT) of the RH119W High Performance Dual Comparator for Linear Technology Customer: Linear Technology, PO# 60334L.1 RAD Job Number: 11-425 Part Type Tested: RH119W High Performance Dual Comparator. Traceability Information: Fab Lot Number: F0258.1, Wafer Number: 13, Assembly Lot Number: 601387.1, Date Code: 1049A. See photograph of unit under test in Appendix A. Quantity of Units: 12 units received, 5 units for biased irradiation, 5 units for unbiased irradiation and 2 units for control. Serial numbers 1438-1442 were biased during irradiation, serial numbers 1443-1447 were unbiased during irradiation and serial numbers 1448 and 1449 were used as control. See Appendix B for the radiation bias connection table. Radiation and Electrical Test Increments: 50 to 300rad(Si)/s ionizing radiation with electrical test increments: pre-irradiation, 20krad(Si), 50krad(Si), 100krad(Si) and 200krad(Si). Pre-Irradiation Burn-In: Burn-In performed by Linear Technology prior to receipt by RAD. Overtest and Post-Irradiation Anneal: No overtest. No anneal. Radiation Test Standard: MIL-STD-750E TM1019 and/or MIL-STD-883H TM1019 Condition A. Test Hardware and Software: LTS2020 Automated Tester, Entity ID TS04, Calibration Date: 04-2811, Calibration Due 04-28-12. LTS2101 Family Board, Entity ID FB02. LTS0607 Test Fixture, Entity ID TF07. RH119 BGSS-0325 DUT Board. Test Program: RH119A.SRC Facility and Radiation Source: Aeroflex RAD's Longmire Laboratories, Colorado Springs, CO. Gamma rays provided by JLSA 81-24 Co60 source. Dosimetry performed by Air Ionization Chamber (AIC) traceable to NIST. Aeroflex RAD's dosimetry has been audited by DSCC and Aeroflex RAD has been awarded Laboratory Suitability for MIL-STD-750 and MIL-STD-883 TM 1019. Irradiation and Test Temperature: Room temperature controlled to 24°C±6°C per MIL-STD-883 and MIL-STD-750. RLAT Result: PASSED. The units-under-test passed the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 1 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 1.0. Overview and Background It is well known that total dose ionizing radiation can cause parametric degradation and ultimately functional failure in electronic devices. The damage occurs via electron-hole pair production, transport and trapping in the dielectric and interface regions. In discrete devices the bulk of the damage is frequently manifested as a reduction in the gain and/or breakdown voltage of the device. The damage will usually anneal with time following the end of the radiation exposure. Due to this annealing, and to ensure a worst-case test condition MIL-STD-883 TM1019.8 calls out a dose rate of 50 to 300rad(Si)/s as Condition A and further specifies that the time from the end of an incremental radiation exposure and electrical testing shall be 1-hour or less and the total time from the end of one incremental irradiation to the beginning of the next incremental radiation step should be 2-hours or less. The work described in this report was performed to meet MIL-STD-883 TM1019.8 Condition A. 2.0. Radiation Test Apparatus The total ionizing dose testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead. During the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by the distance from the source. For high-dose rate experiments the bias boards are placed in a radial fashion equidistant from the raised Co-60 rods with the distance adjusted to provide the required dose rate. The irradiator calibration is maintained by Aeroflex RAD Longmire Laboratories using air ionization chamber (AIC) equipment calibrated with traceability to the National Institute of Standards and Technology (NIST). Figure 2.1 shows a photograph of the JLSA 81-24 Co-60 irradiator at Aeroflex RAD's Longmire Laboratory facility. Aeroflex RAD is currently certified by the Defense Supply Center Columbus (DSCC) for Laboratory Suitability under MIL STD 750 and MIL-STD-883. Additional details regarding Aeroflex RAD dosimetry for TM1019 Condition A testing are available in Aeroflex RAD's report to DSCC entitled: "Dose Rate Mapping of the J.L. Shepherd and Associates Model 81 Irradiator Installed by Radiation Assured Devices". An ISO 9001:2008 and DSCC Certified Company 2 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Figure 2.1. Aeroflex RAD's high dose rate Co-60 irradiator. The dose rate is obtained by positioning the deviceunder-test at a fixed distance from the gamma cell. The dose rate for this irradiator varies from approximately 120rad(Si)/s close to the rods down to 1rad(Si)/s at a distance of approximately 2-feet. An ISO 9001:2008 and DSCC Certified Company 3 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 3.0. Radiation Test Conditions The RH119W High Performance Dual Comparator described in this final report were irradiated using a split 15V supply and with all pins tied to ground, that is biased and unbiased. See the TID Bias Table in Appendix B for the full bias circuits. In our opinion, this bias circuit satisfies the requirements of MILSTD-883H TM1019.8 Section 3.9.3 Bias and Loading Conditions which states "The bias applied to the test devices shall be selected to produce the greatest radiation induced damage or the worst-case damage for the intended application, if known. While maximum voltage is often worst case some bipolar linear device parameters (e.g. input bias current or maximum output load current) exhibit more degradation with 0 V bias." The devices were irradiated to a maximum total ionizing dose level of 200krad(Si) with incremental readings at 20krad(Si), 50krad(Si) and 100krad(Si). Electrical testing occurred within one hour following the end of each irradiation segment. For intermediate irradiations, the parts were tested and returned to total dose exposure within two hours from the end of the previous radiation increment. The TID bias board was positioned in the Co-60 cell to provide the required minimum of 50rad(Si)/s and was located inside a lead-aluminum enclosure. The lead-aluminum enclosure is required under MILSTD-883H TM1019.8 Section 3.4 that reads as follows: "Lead/Aluminum (Pb/Al) container. Test specimens shall be enclosed in a Pb/Al container to minimize dose enhancement effects caused by lowenergy, scattered radiation. A minimum of 1.5 mm Pb, surrounding an inner shield of at least 0.7 mm Al, is required. This Pb/Al container produces an approximate charged particle equilibrium for Si and for TLDs such as CaF2. The radiation field intensity shall be measured inside the Pb/Al container (1) initially, (2) when the source is changed, or (3) when the orientation or configuration of the source, container, or test-fixture is changed. This measurement shall be performed by placing a dosimeter (e.g., a TLD) in the device-irradiation container at the approximate test-device position. If it can be demonstrated that low energy scattered radiation is small enough that it will not cause dosimetry errors due to dose enhancement, the Pb/Al container may be omitted." The final dose rate within the high dose rate lead-aluminum enclosure was determined using calibration calculations based on air ionization chamber (AIC) dosimetry performed just prior to beginning the total dose irradiations. The final dose rate for this work was 55.49rad(Si)/s with a precision of ±5%. An ISO 9001:2008 and DSCC Certified Company 4 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 4.0. Tested Parameters During the total ionizing dose characterization testing the following electrical parameters were measured pre- and post-irradiation: 1. Positive Supply Current (A) @ VS=±15V 2. Negative Supply Current (A) @ VS=±15V 3. Input Offset Voltage 1 (V) @ VS=±15V, VCM=0V 4. Input Offset Voltage 2 (V) @ VS=±15V, VCM=0V 5. Input Offset Current 1 (A) @ VS=±15V, VCM=0V 6. Input Offset Current 2 (A) @ VS=±15V, VCM=0V 7. Positive Bias Current 1 (A) @ VS=±15V, VCM=0V 8. Positive Bias Current 2 (A) @ VS=±15V, VCM=0V 9. Negative Bias Current 1 (A) @ VS=±15V, VCM=0V 10. Negative Bias Current 2 (A) @ VS=±15V, VCM=0V 11. Large signal Voltage Gain 1 (V/mV) @ VS=±15V, VCM=0V 12. Large signal Voltage Gain 2 (V/mV) @ VS=±15V, VCM=0V 13. Common Mode Rejection Ratio 1 (dB) @ VS=±15V 14. Common Mode Rejection Ratio 2 (dB) @ VS=±15V 15. Saturation Voltage 1 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA 16. Saturation Voltage 2 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA 17. Saturation Voltage 1 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA 18. Saturation Voltage 2 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA 19. Output Leakage Current 1 (A) @ VIN=5mV, VOUT to -VS=35V 20. Output Leakage Current 2 (A) @ VIN=5mV, VOUT to -VS=35V Appendix C details the measured parameters, test conditions, pre-irradiation specification and measurement resolution for each of the measurements. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the total ionizing dose test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the device post radiation data sheet specification limits, then the lot could be logged as a failure. An ISO 9001:2008 and DSCC Certified Company 5 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 5.0. Total Ionizing Dose Test Results Based on this criterion the RH119W High Performance Dual Comparator (from the lot traceability information provided on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. Figures 5.1 through 5.20 show plots of all the measured parameters versus total ionizing dose while Tables 5.1 - 5.20 show the corresponding raw data for each of these parameters. In the data plots the solid diamonds are the average of the measured data points for the sample irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the units irradiated with all pins tied to ground. The black lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the biased condition while the shaded lines (solid or dashed) are the average of the data points after application of the KTL statistics on the sample irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. The control units, as expected, show no significant changes to any of the parameters. Therefore we can conclude that the electrical testing remained in control throughout the duration of the tests and the observed degradation was due to the radiation exposure. Appendix D lists the figures used in this section to facilitate the location of a particular parameter. An ISO 9001:2008 and DSCC Certified Company 6 TID Report 11-425 111109 R1.2 Average Biased Average Un-Biased Ps90%/90% (+KTL) Un-Biased Specification MAX Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (+KTL) Biased Positive Supply Current (A) @ VS=±15V 1.40E-02 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.1. Plot of Positive Supply Current (A) @ VS=±15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 7 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.1. Raw data for Positive Supply Current (A) @ VS=±15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Supply Current (A) @ VS=±15V Device 0 20 50 100 200 1438 7.37E-03 7.35E-03 7.34E-03 7.34E-03 7.33E-03 1439 7.34E-03 7.32E-03 7.30E-03 7.30E-03 7.29E-03 1440 7.95E-03 7.93E-03 7.91E-03 7.91E-03 7.90E-03 1441 7.38E-03 7.35E-03 7.34E-03 7.33E-03 7.33E-03 1442 7.38E-03 7.36E-03 7.34E-03 7.33E-03 7.33E-03 1443 7.60E-03 7.59E-03 7.59E-03 7.58E-03 7.56E-03 1444 7.45E-03 7.44E-03 7.38E-03 7.44E-03 7.43E-03 1445 7.34E-03 7.34E-03 7.34E-03 7.34E-03 7.32E-03 1446 7.67E-03 7.66E-03 7.66E-03 7.65E-03 7.64E-03 1447 7.58E-03 7.57E-03 7.56E-03 7.55E-03 7.55E-03 1448 7.38E-03 7.38E-03 7.38E-03 7.37E-03 7.36E-03 1449 7.55E-03 7.55E-03 7.56E-03 7.55E-03 7.56E-03 Biased Statistics Average Biased 7.48E-03 7.46E-03 7.45E-03 7.44E-03 7.44E-03 Std Dev Biased 2.61E-04 2.62E-04 2.60E-04 2.62E-04 2.60E-04 Ps90%/90% (+KTL) Biased 8.20E-03 8.18E-03 8.16E-03 8.16E-03 8.15E-03 Ps90%/90% (-KTL) Biased 6.77E-03 6.74E-03 6.73E-03 6.72E-03 6.72E-03 Un-Biased Statistics Average Un-Biased 7.53E-03 7.52E-03 7.51E-03 7.51E-03 7.50E-03 Std Dev Un-Biased 1.32E-04 1.28E-04 1.39E-04 1.22E-04 1.25E-04 Ps90%/90% (+KTL) Un-Biased 7.89E-03 7.87E-03 7.89E-03 7.85E-03 7.84E-03 Ps90%/90% (-KTL) Un-Biased 7.17E-03 7.17E-03 7.13E-03 7.18E-03 7.16E-03 Specification MAX 1.15E-02 1.15E-02 1.15E-02 1.15E-02 1.15E-02 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 8 TID Report 11-425 111109 R1.2 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Negative Supply Current (A) @ VS=±15V 0.00E+00 -5.00E-04 -1.00E-03 -1.50E-03 -2.00E-03 -2.50E-03 -3.00E-03 -3.50E-03 -4.00E-03 -4.50E-03 -5.00E-03 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.2. Plot of Negative Supply Current (A) @ VS=±15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 9 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.2. Raw data for Negative Supply Current (A) @ VS=±15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Negative Supply Current (A) @ VS=±15V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 -3.20E-03 -3.19E-03 -3.44E-03 -3.21E-03 -3.22E-03 -3.30E-03 -3.24E-03 -3.20E-03 -3.32E-03 -3.30E-03 -3.20E-03 -3.28E-03 Total 20 -3.19E-03 -3.18E-03 -3.43E-03 -3.20E-03 -3.21E-03 -3.31E-03 -3.24E-03 -3.19E-03 -3.32E-03 -3.30E-03 -3.20E-03 -3.28E-03 Dose (krad(Si)) 50 100 -3.19E-03 -3.19E-03 -3.18E-03 -3.17E-03 -3.43E-03 -3.42E-03 -3.19E-03 -3.19E-03 -3.20E-03 -3.21E-03 -3.30E-03 -3.30E-03 -3.24E-03 -3.24E-03 -3.20E-03 -3.20E-03 -3.32E-03 -3.32E-03 -3.30E-03 -3.30E-03 -3.20E-03 -3.19E-03 -3.27E-03 -3.28E-03 200 -3.19E-03 -3.16E-03 -3.41E-03 -3.19E-03 -3.20E-03 -3.30E-03 -3.25E-03 -3.20E-03 -3.33E-03 -3.31E-03 -3.20E-03 -3.29E-03 -3.25E-03 -3.24E-03 -3.24E-03 -3.24E-03 -3.23E-03 1.06E-04 1.06E-04 1.08E-04 1.04E-04 1.02E-04 -2.96E-03 -2.95E-03 -2.94E-03 -2.95E-03 -2.95E-03 -3.54E-03 -3.53E-03 -3.53E-03 -3.52E-03 -3.51E-03 -3.27E-03 5.02E-05 -3.13E-03 -3.41E-03 -4.50E-03 PASS -3.27E-03 5.54E-05 -3.12E-03 -3.42E-03 -4.50E-03 PASS -3.27E-03 5.02E-05 -3.13E-03 -3.41E-03 -4.50E-03 PASS An ISO 9001:2008 and DSCC Certified Company 10 -3.27E-03 5.02E-05 -3.13E-03 -3.41E-03 -4.50E-03 PASS -3.28E-03 5.26E-05 -3.13E-03 -3.42E-03 -4.50E-03 PASS Input Offset Voltage 1 (V) @ VS=±15V, VCM=0V TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 -2.00E-03 -4.00E-03 -6.00E-03 -8.00E-03 -1.00E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.3. Plot of Input Offset Voltage 1 (V) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 11 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.3. Raw data for Input Offset Voltage 1 (V) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Input Offset Voltage 1 (V) @ VS=±15V, VCM=0V Device 0 20 50 100 200 1438 4.00E-04 4.30E-04 4.20E-04 4.40E-04 4.30E-04 1439 4.60E-04 4.80E-04 4.80E-04 4.80E-04 4.70E-04 1440 8.70E-04 8.80E-04 8.80E-04 8.80E-04 8.60E-04 1441 5.60E-04 5.70E-04 5.80E-04 5.70E-04 6.00E-04 1442 5.50E-04 5.70E-04 5.80E-04 5.70E-04 5.70E-04 1443 5.50E-04 5.40E-04 5.20E-04 5.10E-04 4.90E-04 1444 5.00E-04 4.80E-04 4.70E-04 4.70E-04 4.40E-04 1445 5.40E-04 5.20E-04 5.00E-04 4.90E-04 4.70E-04 1446 7.50E-04 7.60E-04 7.50E-04 7.30E-04 7.10E-04 1447 6.10E-04 6.10E-04 6.10E-04 5.70E-04 5.90E-04 1448 4.40E-04 4.50E-04 4.50E-04 4.40E-04 4.30E-04 1449 6.10E-04 6.40E-04 6.40E-04 6.40E-04 6.50E-04 Biased Statistics Average Biased 5.68E-04 5.86E-04 5.88E-04 5.88E-04 5.86E-04 Std Dev Biased 1.81E-04 1.75E-04 1.77E-04 1.73E-04 1.68E-04 Ps90%/90% (+KTL) Biased 1.07E-03 1.07E-03 1.07E-03 1.06E-03 1.05E-03 Ps90%/90% (-KTL) Biased 7.09E-05 1.06E-04 1.03E-04 1.14E-04 1.24E-04 Un-Biased Statistics Average Un-Biased 5.90E-04 5.82E-04 5.70E-04 5.54E-04 5.40E-04 Std Dev Un-Biased 9.77E-05 1.10E-04 1.13E-04 1.05E-04 1.10E-04 Ps90%/90% (+KTL) Un-Biased 8.58E-04 8.84E-04 8.81E-04 8.43E-04 8.43E-04 Ps90%/90% (-KTL) Un-Biased 3.22E-04 2.80E-04 2.59E-04 2.65E-04 2.37E-04 Specification MIN -4.00E-03 -4.00E-03 -4.00E-03 -4.00E-03 -8.00E-03 Status PASS PASS PASS PASS PASS Specification MAX 4.00E-03 4.00E-03 4.00E-03 4.00E-03 8.00E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 12 Input Offset Voltage 2 (V) @ VS=±15V, VCM=0V TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 -2.00E-03 -4.00E-03 -6.00E-03 -8.00E-03 -1.00E-02 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.4. Plot of Input Offset Voltage 2 (V) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 13 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.4. Raw data for Input Offset Voltage 2 (V) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Input Offset Voltage 2 (V) @ VS=±15V, VCM=0V Device 0 20 50 100 200 1438 4.60E-04 5.00E-04 5.00E-04 5.10E-04 5.10E-04 1439 2.70E-04 3.30E-04 3.20E-04 3.30E-04 3.30E-04 1440 4.60E-04 5.00E-04 5.20E-04 5.10E-04 5.20E-04 1441 5.20E-04 5.50E-04 5.60E-04 5.60E-04 5.50E-04 1442 5.90E-04 6.30E-04 6.30E-04 6.20E-04 6.40E-04 1443 5.80E-04 6.00E-04 6.00E-04 6.00E-04 5.70E-04 1444 4.80E-04 4.90E-04 4.80E-04 4.70E-04 4.40E-04 1445 6.30E-04 6.60E-04 6.40E-04 6.30E-04 6.10E-04 1446 4.20E-04 4.50E-04 4.40E-04 4.30E-04 4.10E-04 1447 4.80E-04 4.90E-04 4.80E-04 4.60E-04 4.30E-04 1448 6.30E-04 6.50E-04 6.40E-04 6.50E-04 6.40E-04 1449 5.80E-04 6.00E-04 5.80E-04 6.10E-04 6.00E-04 Biased Statistics Average Biased 4.60E-04 5.02E-04 5.06E-04 5.06E-04 5.10E-04 Std Dev Biased 1.19E-04 1.10E-04 1.15E-04 1.08E-04 1.13E-04 Ps90%/90% (+KTL) Biased 7.86E-04 8.03E-04 8.22E-04 8.03E-04 8.20E-04 Ps90%/90% (-KTL) Biased 1.34E-04 2.01E-04 1.90E-04 2.09E-04 2.00E-04 Un-Biased Statistics Average Un-Biased 5.18E-04 5.38E-04 5.28E-04 5.18E-04 4.92E-04 Std Dev Un-Biased 8.50E-05 8.81E-05 8.67E-05 9.04E-05 9.12E-05 Ps90%/90% (+KTL) Un-Biased 7.51E-04 7.80E-04 7.66E-04 7.66E-04 7.42E-04 Ps90%/90% (-KTL) Un-Biased 2.85E-04 2.96E-04 2.90E-04 2.70E-04 2.42E-04 Specification MIN -4.00E-03 -4.00E-03 -4.00E-03 -4.00E-03 -8.00E-03 Status PASS PASS PASS PASS PASS Specification MAX 4.00E-03 4.00E-03 4.00E-03 4.00E-03 8.00E-03 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 14 Input Offset Current 1 (A) @ VS=±15V, VCM=0V TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.5. Plot of Input Offset Current 1 (A) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 15 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.5. Raw data for Input Offset Current 1 (A) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current 1 (A) @ VS=±15V, VCM=0V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -9.55E-09 -8.25E-09 -1.04E-08 -1.03E-08 -1.23E-08 -5.62E-09 -1.22E-08 -4.56E-09 -1.09E-08 -1.09E-08 -2.77E-09 -1.09E-08 Total 20 -1.73E-08 -1.77E-08 -2.12E-08 -1.86E-08 -2.33E-08 -7.60E-09 -1.30E-08 1.82E-09 -9.04E-09 -8.21E-09 -9.30E-10 -6.31E-09 Dose (krad(Si)) 50 100 -2.37E-08 -3.21E-08 -2.70E-08 -3.25E-08 -3.44E-08 -4.73E-08 -2.87E-08 -3.80E-08 -2.23E-08 -3.82E-08 -2.89E-09 -3.65E-09 -2.98E-09 -4.61E-09 3.67E-09 9.66E-09 -5.40E-09 -3.95E-09 8.00E-11 2.81E-09 -2.00E-11 1.81E-09 -6.31E-09 -1.00E-08 200 -6.24E-08 -5.48E-08 -8.26E-08 -6.38E-08 -5.82E-08 6.93E-09 1.00E-09 1.81E-08 -4.79E-09 1.43E-08 -2.55E-09 -1.10E-08 -1.02E-08 -1.96E-08 -2.72E-08 -3.76E-08 -6.44E-08 1.48E-09 2.57E-09 4.78E-09 6.13E-09 1.08E-08 -6.11E-09 -1.26E-08 -1.41E-08 -2.08E-08 -3.48E-08 -1.42E-08 -2.67E-08 -4.03E-08 -5.44E-08 -9.39E-08 -8.86E-09 3.50E-09 7.39E-10 -1.85E-08 -7.50E-08 PASS 7.50E-08 PASS -7.21E-09 5.48E-09 7.80E-09 -2.22E-08 -1.00E-07 PASS 1.00E-07 PASS -1.50E-09 3.48E-09 8.05E-09 -1.11E-08 -1.50E-07 PASS 1.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 16 5.20E-11 6.15E-09 1.69E-08 -1.68E-08 -3.00E-07 PASS 3.00E-07 PASS 7.12E-09 9.39E-09 3.29E-08 -1.86E-08 -5.00E-07 PASS 5.00E-07 PASS Input Offset Current 2 (A) @ VS=±15V, VCM=0V TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 6.00E-07 4.00E-07 2.00E-07 0.00E+00 -2.00E-07 -4.00E-07 -6.00E-07 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.6. Plot of Input Offset Current 2 (A) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 17 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.6. Raw data for Input Offset Current 2 (A) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Input Offset Current 2 (A) @ VS=±15V, VCM=0V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status Specification MAX Status 0 -1.11E-08 -5.70E-09 -1.02E-08 -9.50E-09 -1.10E-08 -1.22E-08 -1.30E-08 -1.00E-08 -1.17E-08 -8.22E-09 -9.19E-09 -6.76E-09 Total 20 -2.14E-08 -1.60E-08 -2.41E-08 -2.59E-08 -2.39E-08 -1.38E-08 -1.41E-08 -9.35E-09 -1.11E-08 -1.14E-08 -1.09E-08 -8.28E-09 Dose (krad(Si)) 50 100 -3.91E-08 -5.81E-08 -2.91E-08 -4.67E-08 -3.25E-08 -6.09E-08 -3.72E-08 -5.56E-08 -3.70E-08 -6.01E-08 -1.83E-08 -2.03E-08 -1.68E-08 -2.15E-08 -1.75E-08 -2.09E-08 -2.10E-08 -2.28E-08 -1.77E-08 -2.40E-08 -1.28E-08 -1.02E-08 -1.22E-08 -8.21E-09 200 -9.73E-08 -8.16E-08 -9.51E-08 -9.36E-08 -9.13E-08 -2.32E-08 -2.74E-08 -2.96E-08 -3.19E-08 -3.28E-08 -1.12E-08 -1.28E-08 -9.50E-09 -2.23E-08 -3.50E-08 -5.63E-08 -9.18E-08 2.22E-09 3.85E-09 4.10E-09 5.73E-09 6.10E-09 -3.41E-09 -1.17E-08 -2.38E-08 -4.06E-08 -7.51E-08 -1.56E-08 -3.28E-08 -4.62E-08 -7.20E-08 -1.09E-07 -1.10E-08 1.92E-09 -5.77E-09 -1.63E-08 -7.50E-08 PASS 7.50E-08 PASS -1.19E-08 1.97E-09 -6.54E-09 -1.73E-08 -1.00E-07 PASS 1.00E-07 PASS -1.82E-08 1.61E-09 -1.38E-08 -2.27E-08 -1.50E-07 PASS 1.50E-07 PASS An ISO 9001:2008 and DSCC Certified Company 18 -2.19E-08 1.51E-09 -1.78E-08 -2.60E-08 -3.00E-07 PASS 3.00E-07 PASS -2.90E-08 3.86E-09 -1.84E-08 -3.95E-08 -5.00E-07 PASS 5.00E-07 PASS Positive Bias Current 1 (A) @ VS=±15V, VCM=0V TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.50E-06 2.00E-06 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 -2.00E-06 -2.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.7. Plot of Positive Bias Current 1 (A) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 19 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.7. Raw data for Positive Bias Current 1 (A) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 1 (A) @ VS=±15V, VCM=0V Device 0 20 50 100 200 1438 3.32E-07 4.05E-07 4.56E-07 5.69E-07 7.01E-07 1439 3.28E-07 4.10E-07 4.50E-07 5.65E-07 6.79E-07 1440 3.38E-07 4.10E-07 4.88E-07 5.82E-07 7.11E-07 1441 3.36E-07 4.11E-07 4.41E-07 5.67E-07 6.84E-07 1442 3.48E-07 4.20E-07 4.41E-07 5.86E-07 7.09E-07 1443 3.41E-07 4.08E-07 4.46E-07 5.41E-07 6.78E-07 1444 3.61E-07 4.21E-07 4.52E-07 5.69E-07 7.09E-07 1445 3.34E-07 3.91E-07 4.48E-07 5.27E-07 6.59E-07 1446 3.21E-07 3.87E-07 4.24E-07 5.19E-07 6.51E-07 1447 3.56E-07 4.21E-07 4.38E-07 5.53E-07 6.92E-07 1448 3.43E-07 3.44E-07 3.51E-07 3.49E-07 3.46E-07 1449 3.50E-07 3.42E-07 3.48E-07 3.48E-07 3.43E-07 Biased Statistics Average Biased 3.36E-07 4.11E-07 4.55E-07 5.74E-07 6.97E-07 Std Dev Biased 7.56E-09 5.37E-09 1.96E-08 9.50E-09 1.45E-08 Ps90%/90% (+KTL) Biased 3.57E-07 4.26E-07 5.09E-07 6.00E-07 7.36E-07 Ps90%/90% (-KTL) Biased 3.16E-07 3.96E-07 4.01E-07 5.48E-07 6.57E-07 Un-Biased Statistics Average Un-Biased 3.42E-07 4.06E-07 4.41E-07 5.42E-07 6.78E-07 Std Dev Un-Biased 1.64E-08 1.62E-08 1.12E-08 1.99E-08 2.38E-08 Ps90%/90% (+KTL) Un-Biased 3.87E-07 4.50E-07 4.72E-07 5.96E-07 7.43E-07 Ps90%/90% (-KTL) Un-Biased 2.98E-07 3.61E-07 4.11E-07 4.87E-07 6.13E-07 Specification MIN -5.00E-07 -7.50E-07 -1.00E-06 -1.50E-06 -2.00E-06 Status PASS PASS PASS PASS PASS Specification MAX 5.00E-07 7.50E-07 1.00E-06 1.50E-06 2.00E-06 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 20 Positive Bias Current 2 (A) @ VS=±15V, VCM=0V TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.50E-06 2.00E-06 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 -2.00E-06 -2.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.8. Plot of Positive Bias Current 2 (A) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 21 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.8. Raw data for Positive Bias Current 2 (A) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Positive Bias Current 2 (A) @ VS=±15V, VCM=0V Device 0 20 50 100 200 1438 3.29E-07 4.16E-07 4.48E-07 6.09E-07 7.47E-07 1439 3.24E-07 4.13E-07 4.66E-07 6.02E-07 7.36E-07 1440 3.39E-07 4.29E-07 5.14E-07 6.22E-07 7.71E-07 1441 3.38E-07 4.24E-07 5.10E-07 6.11E-07 7.57E-07 1442 3.50E-07 4.36E-07 5.20E-07 6.23E-07 7.57E-07 1443 3.44E-07 4.17E-07 4.98E-07 5.80E-07 7.43E-07 1444 3.62E-07 4.32E-07 5.11E-07 6.02E-07 7.63E-07 1445 3.41E-07 4.09E-07 4.97E-07 5.76E-07 7.33E-07 1446 3.27E-07 3.97E-07 4.54E-07 5.57E-07 7.07E-07 1447 3.62E-07 4.31E-07 5.11E-07 5.96E-07 7.57E-07 1448 3.56E-07 3.55E-07 3.56E-07 3.52E-07 3.55E-07 1449 3.43E-07 3.46E-07 3.47E-07 3.46E-07 3.47E-07 Biased Statistics Average Biased 3.36E-07 4.24E-07 4.92E-07 6.13E-07 7.54E-07 Std Dev Biased 9.60E-09 9.35E-09 3.24E-08 8.61E-09 1.30E-08 Ps90%/90% (+KTL) Biased 3.62E-07 4.49E-07 5.81E-07 6.37E-07 7.89E-07 Ps90%/90% (-KTL) Biased 3.10E-07 3.98E-07 4.03E-07 5.90E-07 7.18E-07 Un-Biased Statistics Average Un-Biased 3.47E-07 4.17E-07 4.94E-07 5.82E-07 7.41E-07 Std Dev Un-Biased 1.48E-08 1.52E-08 2.34E-08 1.80E-08 2.24E-08 Ps90%/90% (+KTL) Un-Biased 3.88E-07 4.59E-07 5.58E-07 6.32E-07 8.02E-07 Ps90%/90% (-KTL) Un-Biased 3.07E-07 3.76E-07 4.30E-07 5.33E-07 6.79E-07 Specification MIN -5.00E-07 -7.50E-07 -1.00E-06 -1.50E-06 -2.00E-06 Status PASS PASS PASS PASS PASS Specification MAX 5.00E-07 7.50E-07 1.00E-06 1.50E-06 2.00E-06 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 22 Negative Bias Current 1 (A) @ VS=±15V, VCM=0V TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.50E-06 2.00E-06 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 -2.00E-06 -2.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.9. Plot of Negative Bias Current 1 (A) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 23 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.9. Raw data for Negative Bias Current 1 (A) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 1 (A) @ VS=±15V, VCM=0V Device 0 20 50 100 200 1438 3.16E-07 3.87E-07 4.55E-07 5.36E-07 6.35E-07 1439 3.17E-07 3.87E-07 4.56E-07 5.31E-07 6.20E-07 1440 3.28E-07 3.92E-07 4.58E-07 5.31E-07 5.84E-07 1441 3.25E-07 3.89E-07 4.56E-07 5.26E-07 6.28E-07 1442 3.34E-07 3.99E-07 4.73E-07 5.48E-07 6.47E-07 1443 3.34E-07 3.97E-07 4.70E-07 5.40E-07 6.84E-07 1444 3.48E-07 4.11E-07 4.83E-07 5.44E-07 7.10E-07 1445 3.33E-07 3.96E-07 4.70E-07 5.40E-07 6.75E-07 1446 3.12E-07 3.76E-07 4.47E-07 5.13E-07 6.41E-07 1447 3.48E-07 4.12E-07 4.85E-07 5.54E-07 7.11E-07 1448 3.48E-07 3.48E-07 3.47E-07 3.47E-07 3.44E-07 1449 3.36E-07 3.39E-07 3.36E-07 3.37E-07 3.38E-07 Biased Statistics Average Biased 3.24E-07 3.91E-07 4.59E-07 5.34E-07 6.23E-07 Std Dev Biased 7.85E-09 5.31E-09 7.52E-09 8.19E-09 2.39E-08 Ps90%/90% (+KTL) Biased 3.46E-07 4.05E-07 4.80E-07 5.57E-07 6.88E-07 Ps90%/90% (-KTL) Biased 3.02E-07 3.76E-07 4.39E-07 5.12E-07 5.57E-07 Un-Biased Statistics Average Un-Biased 3.35E-07 3.98E-07 4.71E-07 5.38E-07 6.84E-07 Std Dev Un-Biased 1.48E-08 1.49E-08 1.52E-08 1.54E-08 2.90E-08 Ps90%/90% (+KTL) Un-Biased 3.76E-07 4.39E-07 5.13E-07 5.81E-07 7.64E-07 Ps90%/90% (-KTL) Un-Biased 2.94E-07 3.57E-07 4.29E-07 4.96E-07 6.05E-07 Specification MIN -5.00E-07 -7.50E-07 -1.00E-06 -1.50E-06 -2.00E-06 Status PASS PASS PASS PASS PASS Specification MAX 5.00E-07 7.50E-07 1.00E-06 1.50E-06 2.00E-06 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 24 Negative Bias Current 2 (A) @ VS=±15V, VCM=0V TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (-KTL) Biased Ps90%/90% (-KTL) Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MIN Specification MAX 2.50E-06 2.00E-06 1.50E-06 1.00E-06 5.00E-07 0.00E+00 -5.00E-07 -1.00E-06 -1.50E-06 -2.00E-06 -2.50E-06 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.10. Plot of Negative Bias Current 2 (A) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 25 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.10. Raw data for Negative Bias Current 2 (A) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Negative Bias Current 2 (A) @ VS=±15V, VCM=0V Device 0 20 50 100 200 1438 3.21E-07 3.93E-07 4.65E-07 5.49E-07 6.51E-07 1439 3.22E-07 4.00E-07 4.75E-07 5.31E-07 6.61E-07 1440 3.29E-07 4.03E-07 4.82E-07 5.49E-07 6.78E-07 1441 3.28E-07 3.99E-07 4.73E-07 5.53E-07 6.62E-07 1442 3.38E-07 4.08E-07 4.83E-07 5.60E-07 6.64E-07 1443 3.32E-07 4.04E-07 4.84E-07 5.57E-07 7.22E-07 1444 3.53E-07 4.19E-07 4.94E-07 5.44E-07 7.34E-07 1445 3.33E-07 4.02E-07 4.81E-07 5.55E-07 7.05E-07 1446 3.13E-07 3.84E-07 4.62E-07 5.36E-07 6.77E-07 1447 3.53E-07 4.21E-07 4.94E-07 5.43E-07 7.28E-07 1448 3.45E-07 3.45E-07 3.42E-07 3.43E-07 3.43E-07 1449 3.38E-07 3.37E-07 3.35E-07 3.37E-07 3.35E-07 Biased Statistics Average Biased 3.27E-07 4.01E-07 4.75E-07 5.48E-07 6.63E-07 Std Dev Biased 6.94E-09 5.71E-09 7.22E-09 1.08E-08 9.71E-09 Ps90%/90% (+KTL) Biased 3.46E-07 4.16E-07 4.95E-07 5.78E-07 6.90E-07 Ps90%/90% (-KTL) Biased 3.08E-07 3.85E-07 4.56E-07 5.19E-07 6.37E-07 Un-Biased Statistics Average Un-Biased 3.37E-07 4.06E-07 4.83E-07 5.47E-07 7.13E-07 Std Dev Un-Biased 1.70E-08 1.50E-08 1.33E-08 8.95E-09 2.29E-08 Ps90%/90% (+KTL) Un-Biased 3.83E-07 4.47E-07 5.20E-07 5.72E-07 7.76E-07 Ps90%/90% (-KTL) Un-Biased 2.90E-07 3.64E-07 4.47E-07 5.23E-07 6.50E-07 Specification MIN -5.00E-07 -7.50E-07 -1.00E-06 -1.50E-06 -2.00E-06 Status PASS PASS PASS PASS PASS Specification MAX 5.00E-07 7.50E-07 1.00E-06 1.50E-06 2.00E-06 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 26 TID Report 11-425 111109 R1.2 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large signal Voltage Gain 1 (V/mV) @ VS=±15V, VCM=0V 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.11. Plot of Large signal Voltage Gain 1 (V/mV) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 27 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.11. Raw data for Large signal Voltage Gain 1 (V/mV) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large signal Voltage Gain 1 (V/mV) @ VS=±15V, VCM=0V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 4.77E+01 6.42E+01 4.14E+01 4.84E+01 4.16E+01 3.85E+01 4.00E+01 4.95E+01 3.66E+01 3.34E+01 4.39E+01 4.87E+01 Total 20 3.74E+01 5.73E+01 4.45E+01 5.35E+01 4.14E+01 4.55E+01 5.16E+01 5.01E+01 3.05E+01 4.45E+01 4.71E+01 4.11E+01 Dose (krad(Si)) 50 100 3.99E+01 4.76E+01 5.73E+01 5.14E+01 4.14E+01 3.56E+01 6.65E+01 7.83E+01 4.42E+01 4.84E+01 3.34E+01 4.17E+01 5.68E+01 4.05E+01 6.08E+01 5.70E+01 4.51E+01 4.91E+01 4.11E+01 4.11E+01 5.19E+01 5.24E+01 4.91E+01 3.37E+01 200 3.73E+01 5.12E+01 4.84E+01 5.39E+01 4.42E+01 3.76E+01 4.73E+01 7.13E+01 4.11E+01 5.47E+01 4.03E+01 3.36E+01 4.87E+01 9.29E+00 7.41E+01 2.32E+01 4.68E+01 8.34E+00 6.97E+01 2.40E+01 4.99E+01 1.16E+01 8.16E+01 1.81E+01 5.23E+01 1.58E+01 9.55E+01 9.06E+00 4.70E+01 6.50E+00 6.48E+01 2.92E+01 3.96E+01 6.06E+00 5.62E+01 2.30E+01 1.00E+01 PASS 4.44E+01 8.35E+00 6.73E+01 2.15E+01 1.00E+01 PASS 4.74E+01 1.13E+01 7.84E+01 1.65E+01 1.00E+01 PASS 4.59E+01 7.13E+00 6.54E+01 2.63E+01 1.00E+01 PASS 5.04E+01 1.34E+01 8.71E+01 1.37E+01 5.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 28 TID Report 11-425 111109 R1.2 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased Large signal Voltage Gain 2 (V/mV) @ VS=±15V, VCM=0V 1.00E+02 9.00E+01 8.00E+01 7.00E+01 6.00E+01 5.00E+01 4.00E+01 3.00E+01 2.00E+01 1.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.12. Plot of Large signal Voltage Gain 2 (V/mV) @ VS=±15V, VCM=0V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 29 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.12. Raw data for Large signal Voltage Gain 2 (V/mV) @ VS=±15V, VCM=0V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Large signal Voltage Gain 2 (V/mV) @ VS=±15V, VCM=0V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 8.36E+01 7.46E+01 7.12E+01 6.78E+01 6.58E+01 8.89E+01 7.82E+01 9.40E+01 5.68E+01 7.64E+01 9.27E+01 7.56E+01 Total 20 7.81E+01 8.67E+01 6.80E+01 7.74E+01 6.58E+01 4.87E+01 6.03E+01 9.54E+01 8.29E+01 7.73E+01 7.83E+01 7.48E+01 Dose (krad(Si)) 50 100 7.87E+01 6.91E+01 7.57E+01 8.74E+01 6.80E+01 9.27E+01 7.83E+01 7.74E+01 7.83E+01 7.74E+01 6.78E+01 7.31E+01 8.36E+01 5.77E+01 9.14E+01 6.58E+01 7.38E+01 6.88E+01 8.16E+01 9.91E+01 9.27E+01 6.09E+01 7.31E+01 5.98E+01 200 6.88E+01 1.04E+02 6.84E+01 7.56E+01 5.93E+01 7.65E+01 1.02E+02 8.66E+01 9.20E+01 8.49E+01 6.93E+01 9.01E+01 7.26E+01 7.00E+00 9.18E+01 5.34E+01 7.52E+01 8.45E+00 9.84E+01 5.20E+01 7.58E+01 4.52E+00 8.82E+01 6.34E+01 8.08E+01 9.29E+00 1.06E+02 5.53E+01 7.53E+01 1.72E+01 1.23E+02 2.80E+01 7.89E+01 1.43E+01 1.18E+02 3.95E+01 1.00E+01 PASS 7.29E+01 1.85E+01 1.24E+02 2.22E+01 1.00E+01 PASS 7.96E+01 9.11E+00 1.05E+02 5.47E+01 1.00E+01 PASS 7.29E+01 1.57E+01 1.16E+02 2.99E+01 1.00E+01 PASS 8.84E+01 9.35E+00 1.14E+02 6.27E+01 5.00E+00 PASS An ISO 9001:2008 and DSCC Certified Company 30 Common Mode Rejection Ratio 1 (dB) @ VS=±15V TID Report 11-425 111109 R1.2 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.13. Plot of Common Mode Rejection Ratio 1 (dB) @ VS=±15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 31 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.13. Raw data for Common Mode Rejection Ratio 1 (dB) @ VS=±15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio 1 (dB) @ VS=±15V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.10E+02 1.37E+02 1.15E+02 1.21E+02 1.10E+02 1.28E+02 1.13E+02 1.19E+02 1.13E+02 1.18E+02 1.25E+02 1.22E+02 Total 20 1.14E+02 1.27E+02 1.18E+02 1.18E+02 1.18E+02 1.15E+02 1.21E+02 1.13E+02 1.07E+02 1.20E+02 1.15E+02 1.30E+02 Dose (krad(Si)) 50 100 1.14E+02 1.14E+02 1.38E+02 1.24E+02 1.11E+02 1.18E+02 1.22E+02 1.39E+02 1.13E+02 1.11E+02 1.18E+02 1.26E+02 1.12E+02 1.16E+02 1.13E+02 1.22E+02 1.07E+02 1.09E+02 1.17E+02 1.15E+02 1.25E+02 1.20E+02 1.22E+02 1.16E+02 200 1.12E+02 1.42E+02 1.18E+02 1.42E+02 1.13E+02 1.17E+02 1.14E+02 1.22E+02 1.13E+02 1.13E+02 1.17E+02 1.18E+02 1.18E+02 1.14E+01 1.50E+02 8.72E+01 1.19E+02 5.05E+00 1.33E+02 1.05E+02 1.20E+02 1.13E+01 1.51E+02 8.85E+01 1.21E+02 1.10E+01 1.51E+02 9.08E+01 1.25E+02 1.53E+01 1.67E+02 8.34E+01 1.18E+02 6.33E+00 1.36E+02 1.01E+02 9.00E+01 PASS 1.15E+02 5.78E+00 1.31E+02 9.95E+01 9.00E+01 PASS 1.13E+02 4.30E+00 1.25E+02 1.02E+02 9.00E+01 PASS 1.18E+02 6.38E+00 1.35E+02 1.00E+02 9.00E+01 PASS 1.16E+02 3.90E+00 1.27E+02 1.05E+02 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 32 Common Mode Rejection Ratio 2 (dB) @ VS=±15V TID Report 11-425 111109 R1.2 Average Biased Average Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Ps90%/90% (-KTL) Biased 1.40E+02 1.20E+02 1.00E+02 8.00E+01 6.00E+01 4.00E+01 2.00E+01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.14. Plot of Common Mode Rejection Ratio 2 (dB) @ VS=±15V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 33 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.14. Raw data for Common Mode Rejection Ratio 2 (dB) @ VS=±15V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Common Mode Rejection Ratio 2 (dB) @ VS=±15V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MIN Status 0 1.42E+02 1.20E+02 1.09E+02 1.30E+02 1.39E+02 1.42E+02 1.34E+02 1.25E+02 1.30E+02 1.20E+02 1.28E+02 1.20E+02 Total 20 1.20E+02 1.14E+02 1.09E+02 1.29E+02 1.19E+02 1.13E+02 1.42E+02 1.22E+02 1.20E+02 1.19E+02 1.29E+02 1.14E+02 Dose (krad(Si)) 50 100 1.25E+02 1.28E+02 1.23E+02 1.20E+02 1.09E+02 1.09E+02 1.21E+02 1.10E+02 1.36E+02 1.36E+02 1.15E+02 1.39E+02 1.34E+02 1.25E+02 1.16E+02 1.28E+02 1.25E+02 1.21E+02 1.19E+02 1.42E+02 1.27E+02 1.25E+02 1.10E+02 1.12E+02 200 1.20E+02 1.20E+02 1.09E+02 1.14E+02 1.26E+02 1.26E+02 1.15E+02 1.20E+02 1.20E+02 1.26E+02 1.39E+02 1.14E+02 1.28E+02 1.35E+01 1.65E+02 9.08E+01 1.18E+02 7.76E+00 1.39E+02 9.69E+01 1.23E+02 9.93E+00 1.50E+02 9.56E+01 1.21E+02 1.17E+01 1.53E+02 8.86E+01 1.18E+02 6.54E+00 1.36E+02 9.98E+01 1.30E+02 8.61E+00 1.54E+02 1.07E+02 9.00E+01 PASS 1.23E+02 1.12E+01 1.54E+02 9.25E+01 9.00E+01 PASS 1.22E+02 7.99E+00 1.44E+02 9.99E+01 9.00E+01 PASS 1.31E+02 8.95E+00 1.56E+02 1.07E+02 9.00E+01 PASS 1.22E+02 4.40E+00 1.34E+02 1.09E+02 9.00E+01 PASS An ISO 9001:2008 and DSCC Certified Company 34 Saturation Voltage 1 (V) @ +VS = +4.5V, -VS=0V, VIN=6mV, ISINK = 3.2mA TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 4.50E-01 4.00E-01 3.50E-01 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.15. Plot of Saturation Voltage 1 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 35 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.15. Raw data for Saturation Voltage 1 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Saturation Voltage 1 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA Device 0 20 50 100 200 1438 3.07E-01 3.07E-01 3.09E-01 3.13E-01 3.17E-01 1439 3.05E-01 3.06E-01 3.08E-01 3.11E-01 3.16E-01 1440 3.00E-01 3.01E-01 3.03E-01 3.07E-01 3.10E-01 1441 3.10E-01 3.10E-01 3.10E-01 3.14E-01 3.19E-01 1442 3.11E-01 3.10E-01 3.11E-01 3.14E-01 3.20E-01 1443 3.05E-01 3.04E-01 3.06E-01 3.09E-01 3.13E-01 1444 3.09E-01 3.08E-01 3.09E-01 3.11E-01 3.16E-01 1445 3.05E-01 3.03E-01 3.06E-01 3.08E-01 3.13E-01 1446 3.03E-01 3.02E-01 3.04E-01 3.06E-01 3.11E-01 1447 3.10E-01 3.09E-01 3.11E-01 3.12E-01 3.18E-01 1448 3.00E-01 3.01E-01 3.01E-01 3.02E-01 3.01E-01 1449 3.07E-01 3.05E-01 3.06E-01 3.06E-01 3.06E-01 Biased Statistics Average Biased 3.07E-01 3.07E-01 3.08E-01 3.12E-01 3.16E-01 Std Dev Biased 4.39E-03 3.70E-03 3.11E-03 2.95E-03 3.91E-03 Ps90%/90% (+KTL) Biased 3.19E-01 3.17E-01 3.17E-01 3.20E-01 3.27E-01 Ps90%/90% (-KTL) Biased 2.95E-01 2.97E-01 3.00E-01 3.04E-01 3.06E-01 Un-Biased Statistics Average Un-Biased 3.06E-01 3.05E-01 3.07E-01 3.09E-01 3.14E-01 Std Dev Un-Biased 2.97E-03 3.11E-03 2.77E-03 2.39E-03 2.77E-03 Ps90%/90% (+KTL) Un-Biased 3.15E-01 3.14E-01 3.15E-01 3.16E-01 3.22E-01 Ps90%/90% (-KTL) Un-Biased 2.98E-01 2.97E-01 3.00E-01 3.03E-01 3.07E-01 Specification MAX 4.00E-01 4.00E-01 4.00E-01 4.00E-01 4.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 36 Saturation Voltage 2 (V) @ +VS = +4.5V, -VS=0V, VIN=6mV, ISINK = 3.2mA TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 4.50E-01 4.00E-01 3.50E-01 3.00E-01 2.50E-01 2.00E-01 1.50E-01 1.00E-01 5.00E-02 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.16. Plot of Saturation Voltage 2 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 37 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.16. Raw data for Saturation Voltage 2 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Saturation Voltage 2 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA Device 0 20 50 100 200 1438 3.07E-01 3.07E-01 3.09E-01 3.12E-01 3.16E-01 1439 3.04E-01 3.04E-01 3.07E-01 3.09E-01 3.14E-01 1440 3.02E-01 3.00E-01 3.02E-01 3.05E-01 3.11E-01 1441 3.05E-01 3.05E-01 3.06E-01 3.11E-01 3.15E-01 1442 3.09E-01 3.08E-01 3.11E-01 3.13E-01 3.18E-01 1443 3.02E-01 3.00E-01 3.03E-01 3.05E-01 3.10E-01 1444 3.08E-01 3.05E-01 3.07E-01 3.10E-01 3.14E-01 1445 3.01E-01 3.00E-01 3.01E-01 3.03E-01 3.09E-01 1446 3.03E-01 3.01E-01 3.02E-01 3.04E-01 3.09E-01 1447 3.09E-01 3.06E-01 3.08E-01 3.09E-01 3.16E-01 1448 2.97E-01 2.96E-01 2.96E-01 2.96E-01 2.95E-01 1449 3.03E-01 3.02E-01 3.03E-01 3.02E-01 3.02E-01 Biased Statistics Average Biased 3.05E-01 3.05E-01 3.07E-01 3.10E-01 3.15E-01 Std Dev Biased 2.70E-03 3.11E-03 3.39E-03 3.16E-03 2.59E-03 Ps90%/90% (+KTL) Biased 3.13E-01 3.13E-01 3.16E-01 3.19E-01 3.22E-01 Ps90%/90% (-KTL) Biased 2.98E-01 2.96E-01 2.98E-01 3.01E-01 3.08E-01 Un-Biased Statistics Average Un-Biased 3.05E-01 3.02E-01 3.04E-01 3.06E-01 3.12E-01 Std Dev Un-Biased 3.65E-03 2.88E-03 3.11E-03 3.11E-03 3.21E-03 Ps90%/90% (+KTL) Un-Biased 3.15E-01 3.10E-01 3.13E-01 3.15E-01 3.20E-01 Ps90%/90% (-KTL) Un-Biased 2.95E-01 2.95E-01 2.96E-01 2.98E-01 3.03E-01 Specification MAX 4.00E-01 4.00E-01 4.00E-01 4.00E-01 4.00E-01 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 38 Saturation Voltage 1 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.60E+00 1.40E+00 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.17. Plot of Saturation Voltage 1 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 39 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.17. Raw data for Saturation Voltage 1 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Saturation Voltage 1 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA Device 0 20 50 100 200 1438 6.40E-01 6.37E-01 6.39E-01 6.43E-01 6.48E-01 1439 6.32E-01 6.28E-01 6.32E-01 6.37E-01 6.44E-01 1440 6.17E-01 6.15E-01 6.19E-01 6.22E-01 6.27E-01 1441 6.32E-01 6.30E-01 6.33E-01 6.39E-01 6.44E-01 1442 6.40E-01 6.37E-01 6.39E-01 6.44E-01 6.50E-01 1443 6.28E-01 6.28E-01 6.30E-01 6.33E-01 6.42E-01 1444 6.36E-01 6.34E-01 6.41E-01 6.38E-01 6.45E-01 1445 6.35E-01 6.30E-01 6.34E-01 6.35E-01 6.41E-01 1446 6.20E-01 6.18E-01 6.20E-01 6.23E-01 6.29E-01 1447 6.34E-01 6.33E-01 6.34E-01 6.38E-01 6.44E-01 1448 6.19E-01 6.20E-01 6.20E-01 6.20E-01 6.21E-01 1449 6.26E-01 6.26E-01 6.26E-01 6.25E-01 6.26E-01 Biased Statistics Average Biased 6.32E-01 6.29E-01 6.32E-01 6.37E-01 6.43E-01 Std Dev Biased 9.39E-03 9.02E-03 8.17E-03 8.86E-03 9.10E-03 Ps90%/90% (+KTL) Biased 6.58E-01 6.54E-01 6.55E-01 6.61E-01 6.68E-01 Ps90%/90% (-KTL) Biased 6.06E-01 6.05E-01 6.10E-01 6.13E-01 6.18E-01 Un-Biased Statistics Average Un-Biased 6.31E-01 6.29E-01 6.32E-01 6.33E-01 6.40E-01 Std Dev Un-Biased 6.69E-03 6.39E-03 7.69E-03 6.19E-03 6.46E-03 Ps90%/90% (+KTL) Un-Biased 6.49E-01 6.46E-01 6.53E-01 6.50E-01 6.58E-01 Ps90%/90% (-KTL) Un-Biased 6.12E-01 6.11E-01 6.11E-01 6.16E-01 6.22E-01 Specification MAX 1.50E+00 1.50E+00 1.50E+00 1.50E+00 1.50E+00 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 40 Saturation Voltage 2 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Specification MAX 1.60E+00 1.40E+00 1.20E+00 1.00E+00 8.00E-01 6.00E-01 4.00E-01 2.00E-01 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.18. Plot of Saturation Voltage 2 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 41 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.18. Raw data for Saturation Voltage 2 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Total Dose (krad(Si)) Saturation Voltage 2 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA Device 0 20 50 100 200 1438 6.29E-01 6.25E-01 6.29E-01 6.31E-01 6.39E-01 1439 6.22E-01 6.17E-01 6.23E-01 6.26E-01 6.32E-01 1440 6.15E-01 6.12E-01 6.17E-01 6.20E-01 6.27E-01 1441 6.25E-01 6.22E-01 6.24E-01 6.29E-01 6.35E-01 1442 6.29E-01 6.27E-01 6.29E-01 6.35E-01 6.39E-01 1443 6.24E-01 6.20E-01 6.21E-01 6.26E-01 6.34E-01 1444 6.32E-01 6.29E-01 6.35E-01 6.34E-01 6.41E-01 1445 6.23E-01 6.19E-01 6.21E-01 6.23E-01 6.30E-01 1446 6.15E-01 6.11E-01 6.14E-01 6.17E-01 6.25E-01 1447 6.33E-01 6.31E-01 6.32E-01 6.34E-01 6.42E-01 1448 6.10E-01 6.10E-01 6.11E-01 6.11E-01 6.11E-01 1449 6.18E-01 6.19E-01 6.19E-01 6.18E-01 6.17E-01 Biased Statistics Average Biased 6.24E-01 6.21E-01 6.24E-01 6.28E-01 6.34E-01 Std Dev Biased 5.83E-03 6.11E-03 4.98E-03 5.63E-03 5.08E-03 Ps90%/90% (+KTL) Biased 6.40E-01 6.37E-01 6.38E-01 6.44E-01 6.48E-01 Ps90%/90% (-KTL) Biased 6.08E-01 6.04E-01 6.11E-01 6.13E-01 6.20E-01 Un-Biased Statistics Average Un-Biased 6.25E-01 6.22E-01 6.25E-01 6.27E-01 6.34E-01 Std Dev Un-Biased 7.37E-03 8.12E-03 8.68E-03 7.33E-03 7.23E-03 Ps90%/90% (+KTL) Un-Biased 6.46E-01 6.44E-01 6.48E-01 6.47E-01 6.54E-01 Ps90%/90% (-KTL) Un-Biased 6.05E-01 6.00E-01 6.01E-01 6.07E-01 6.15E-01 Specification MAX 1.50E+00 1.50E+00 1.50E+00 1.50E+00 1.50E+00 Status PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 42 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Output Leakage Current 1 (A) @ VIN=5mV, VOUT to VS=35V Specification MAX 2.50E-06 2.00E-06 1.50E-06 1.00E-06 5.00E-07 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.19. Plot of Output Leakage Current 1 (A) @ VIN=5mV, VOUT to -VS=35V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 43 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.19. Raw data for Output Leakage Current 1 (A) @ VIN=5mV, VOUT to -VS=35V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Leakage Current 1 (A) @ VIN=5mV, VOUT to -VS=35V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 3.00E-09 1.00E-09 3.00E-09 3.00E-09 4.00E-09 0.00E+00 0.00E+00 2.00E-09 4.00E-09 1.00E-09 0.00E+00 2.00E-09 Total 20 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.00E-09 0.00E+00 0.00E+00 1.00E-09 1.00E-09 2.00E-09 2.00E-09 4.00E-09 2.80E-09 4.00E-10 3.20E-09 2.20E-09 1.00E-09 1.10E-09 8.94E-10 2.95E-09 1.92E-09 1.00E-09 5.80E-09 2.85E-09 1.13E-08 7.47E-09 3.74E-09 -2.04E-10 -2.05E-09 -4.89E-09 -3.07E-09 -1.74E-09 1.40E-09 8.00E-10 1.00E-09 1.60E-09 1.60E-09 1.67E-09 8.37E-10 1.00E-09 2.51E-09 1.34E-09 5.99E-09 3.09E-09 3.74E-09 8.48E-09 5.28E-09 -3.19E-09 -1.49E-09 -1.74E-09 -5.28E-09 -2.08E-09 2.00E-06 2.00E-06 2.00E-06 2.00E-06 2.00E-06 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 44 Dose (krad(Si)) 50 100 200 8.00E-09 2.00E-09 0.00E+00 3.00E-09 5.00E-09 2.00E-09 2.00E-09 0.00E+00 0.00E+00 3.00E-09 3.00E-09 1.00E-09 0.00E+00 1.00E-09 2.00E-09 1.00E-09 1.00E-09 0.00E+00 0.00E+00 0.00E+00 1.00E-09 2.00E-09 0.00E+00 3.00E-09 2.00E-09 6.00E-09 3.00E-09 0.00E+00 1.00E-09 1.00E-09 4.00E-09 4.00E-09 4.00E-09 0.00E+00 2.00E-09 3.00E-09 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Average Biased Average Un-Biased Ps90%/90% (+KTL) Biased Ps90%/90% (+KTL) Un-Biased Output Leakage Current 2 (A) @ VIN=5mV, VOUT to VS=35V Specification MAX 2.50E-06 2.00E-06 1.50E-06 1.00E-06 5.00E-07 0.00E+00 0 50 100 150 200 Total Dose (krad(Si)) Figure 5.20. Plot of Output Leakage Current 2 (A) @ VIN=5mV, VOUT to -VS=35V versus total dose. The solid diamonds are the average of the measured data points for the samples irradiated under electrical bias while the shaded diamonds are the average of the measured data points for the samples irradiated with all pins tied to ground. The black lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated under electrical bias while the gray lines (solid and/or dashed) are the average of the data points after application of the KTL statistics on the samples irradiated in the unbiased condition. The red dotted line(s) are the pre- and/or post-irradiation minimum and/or maximum specification value as defined in the datasheet and/or test plan. An ISO 9001:2008 and DSCC Certified Company 45 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table 5.20. Raw data for Output Leakage Current 2 (A) @ VIN=5mV, VOUT to -VS=35V versus total dose, including the statistical analysis, specification and the status of the testing (pass/fail). Output Leakage Current 2 (A) @ VIN=5mV, VOUT to -VS=35V Device 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 Biased Statistics Average Biased Std Dev Biased Ps90%/90% (+KTL) Biased Ps90%/90% (-KTL) Biased Un-Biased Statistics Average Un-Biased Std Dev Un-Biased Ps90%/90% (+KTL) Un-Biased Ps90%/90% (-KTL) Un-Biased Specification MAX Status 0 1.00E-09 3.00E-09 1.00E-09 1.00E-09 1.00E-09 0.00E+00 4.00E-09 2.00E-09 0.00E+00 0.00E+00 5.00E-09 0.00E+00 Total 20 4.00E-09 4.00E-09 1.00E-09 5.00E-09 0.00E+00 4.00E-09 3.00E-09 0.00E+00 0.00E+00 0.00E+00 2.00E-09 1.00E-09 1.40E-09 2.80E-09 2.00E-09 1.20E-09 2.40E-09 8.94E-10 2.17E-09 1.41E-09 8.37E-10 2.30E-09 3.85E-09 8.74E-09 5.88E-09 3.49E-09 8.71E-09 -1.05E-09 -3.14E-09 -1.88E-09 -1.09E-09 -3.91E-09 1.20E-09 1.40E-09 2.20E-09 2.20E-09 2.20E-09 1.79E-09 1.95E-09 1.48E-09 1.48E-09 1.48E-09 6.11E-09 6.75E-09 6.27E-09 6.27E-09 6.27E-09 -3.71E-09 -3.95E-09 -1.87E-09 -1.87E-09 -1.87E-09 2.00E-06 2.00E-06 2.00E-06 2.00E-06 2.00E-06 PASS PASS PASS PASS PASS An ISO 9001:2008 and DSCC Certified Company 46 Dose (krad(Si)) 50 100 200 1.00E-09 1.00E-09 1.00E-09 0.00E+00 1.00E-09 0.00E+00 3.00E-09 2.00E-09 6.00E-09 3.00E-09 0.00E+00 3.00E-09 3.00E-09 2.00E-09 2.00E-09 2.00E-09 0.00E+00 4.00E-09 3.00E-09 2.00E-09 2.00E-09 4.00E-09 4.00E-09 2.00E-09 0.00E+00 2.00E-09 0.00E+00 2.00E-09 3.00E-09 3.00E-09 2.00E-09 5.00E-09 3.00E-09 1.00E-09 0.00E+00 4.00E-09 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 6.0. Summary / Conclusions The total ionizing dose testing described in this final report was performed using the facilities at Aeroflex RAD's Longmire Laboratories in Colorado Springs, CO. The high dose rate total ionizing dose (TID) source is a JLSA 81-24 irradiator modified to provide a panoramic exposure. The Co-60 rods are held in the base of the irradiator heavily shielded by lead, during the radiation exposures the rod is raised by an electronic timer/controller and the exposure is performed in air. The dose rate for this irradiator in this configuration ranges from <1rad(Si)/s to a maximum of approximately 120rad(Si)/s, determined by the distance from the source. The parametric data was obtained as "read and record" and all the raw data plus an attributes summary are contained in this report as well as in a separate Excel file. The attributes data contains the average, standard deviation and the average with the KTL values applied. The KTL value used in this work is 2.742 per MIL-HDBK-814 using one sided tolerance limits of 90/90 and a 5-piece sample size. The 90/90 KTL values were selected to match the statistical levels specified in the MIL-PRF-38535 sampling plan for the qualification of a radiation hardness assured (RHA) component. Note that the following criteria must be met for a device to pass the total ionizing dose test: following the radiation exposure each of the 5 pieces irradiated under electrical bias shall pass the specification value. The units irradiated without electrical bias and the KTL statistics are included in this report for reference only. If any of the 5 pieces irradiated under electrical bias exceed the datasheet specifications, then the lot could be logged as a failure. Based on this criterion the RH119W High Performance Dual Comparator (from the lot date code identified on the first page of this test report) PASSED the total ionizing dose test to the maximum tested dose level of 200krad(Si) with all parameters remaining within their datasheet specifications. An ISO 9001:2008 and DSCC Certified Company 47 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix A: Photograph of a Sample Unit-Under-Test to Show Part Traceability An ISO 9001:2008 and DSCC Certified Company 48 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix B: Radiation Bias Connections and Absolute Maximum Ratings TID Radiation Biased Conditions: Extracted from Linear Technology RH119 Datasheet. Pin Function 1 OUT1 Connection / Bias +15V Via 10kΩ 2 GND1 GND 3 +IN1 4 -IN1 5 V- To Pin 8 and –15V via 10kΩ To Pin 9 and +15V via 10kΩ To Pin 8 via 100Ω -15V 6 OUT2 +15V Via 10kΩ 7 GND2 8 +IN2 9 -IN2 GND To Pin 3 and –15V via 10kΩ To Pin 4 via 100Ω To Pin 4 and +15V via 10kΩ 10 V+ +15V Figure B.1. Irradiation bias drawing for the units to be irradiated under electrical bias. This figure was extracted from Linear Technology RH119 Datasheet. An ISO 9001:2008 and DSCC Certified Company 49 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 TID Radiation Unbiased Conditions: Pin Function Connection / Bias 1 OUT1 GND 2 GND1 GND 3 +IN1 GND 4 -IN1 GND 5 V- GND 6 OUT2 GND 7 GND2 GND 8 +IN2 GND 9 -IN2 GND 10 V+ GND Absolute Maximum Ratings: Parameter Max Rating Supply Voltage 36V Output to Negative supply Voltage 36V Ground to Negative Supply Voltage 25V Ground to Positive Supply Voltage 18V Differential Input Voltage ±5V Differential Input Current ±5mA Figure B.2. W package drawing (for reference only). This figure was extracted from Linear Technology RH119 Datasheet. An ISO 9001:2008 and DSCC Certified Company 50 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix C: Electrical Test Parameters and Conditions The expected ranges of values as well as the measurement conditions are taken from Linear Technology RH119 Datasheet. All electrical tests for this device are performed on one of Aeroflex RAD's LTS2020 Test Systems. The LTS2020 Test System is a programmable parametric tester that provides parameter measurements for a variety of digital, analog and mixed signal products including voltage regulators, voltage comparators, D to A and A to D converters. The LTS2020 Test System achieves accuracy and sensitivity through the use of software self-calibration and an internal relay matrix with separate family boards and custom personality adapter boards. The tester uses this relay matrix to connect the required test circuits, select the appropriate voltage / current sources and establish the needed measurement loops for all the tests performed. The measured parameters and test conditions are shown in Table C.1. A listing of the measurement precision/resolution for each parameter is shown in Table C.2. The precision/resolution values were obtained from test data or from the DAC resolution of the LTS-2020 for the particular test shown, whichever is greater. To generate the precision/resolution shown in Table C.2, one of the units-under-test was tested repetitively (a total of 10-times with re-insertion between tests) to obtain the average test value and standard deviation. Using this test data MIL-HDBK-814 90/90 KTL statistics were applied to the measured standard deviation to generate the final measurement range. This value encompasses the precision/resolution of all aspects of the test system, including the LTS2020 mainframe, family board, socket assembly and DUT board as well as insertion error. In some cases, the measurement resolution is limited by the internal DACs, which results in a measured standard deviation of zero. In these instances the precision/resolution will be reported back as the LSB of the DAC. Note that the testing and statistics used in this document are based on an “analysis of variables” technique, which relies on small sample sizes to qualify much larger lot sizes (see MIL-HDBK-814, p. 91 for a discussion of statistical treatments). Not all measured parameters are well suited to this approach due to inherent large variations. If necessary, larger samples sizes could be used to qualify these parameters using an “attributes” approach. An ISO 9001:2008 and DSCC Certified Company 51 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Table C.1. Measured parameters and test conditions for the RH119W High Performance Dual Comparator. Parameter Symbol Test Conditions Positive Supply Current (A) Icc VS=±15V Negative Supply Current (A) Iss VS=±15V Input Offset Voltage (V) Vos1, Vos2 VS=±15V, VCM=0V Input Offset Current (A) Ios1, Ios2 VS=±15V, VCM=0V Positive Bias Current (A) Ib+1, Ib+2 VS=±15V, VCM=0V Negative Bias Current (A) Ib-1, Ib-2 VS=±15V, VCM=0V Large signal Voltage Gain (V/mV) Avol1, Avol2 VS=±15V, VCM=0V Common Mode Rejection Ratio (dB) CMRR1, CMRR2 VS=±15V Saturation Voltage (V) Vola1, Vola2 +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA Saturation Voltage (V) Volb1, Volb2 VS=±15V, VIN=-5mV, IOUT = 25mA Output Leakage Current (A) Icex1, Icex2 VS=±15V, VIN=5mV, VOUT to -VS=35V Table C.2. Measured parameters, pre-irradiation specifications and measurement precision for the RH119W High Performance Dual Comparator. Parameter Pre-Irradiation Specification MIN Icc MAX 1.15E-02 Measurement Precision/Resolution ±1.05E-04 Iss -4.50E-03 ±9.97E-06 Vos1, Vos2 -4.00E-03 4.00E-03 ±3.05E-05 Ios1, Ios2 -7.50E-08 7.50E-08 ±3.64E-09 Ib+1, Ib+2 -5.00E-07 5.00E-07 ±9.61E-09 Ib-1, Ib-2 -5.00E-07 5.00E-07 ±7.02E-09 Avol1, Avol2 1.00E+01 ±2.16E+01 CMRR1, CMRR2 9.00E+01 ±1.63E+01 Vola1, Vola2 4.00E-01 ±4.61E-03 Volb1, Volb2 1.50E+00 ±7.43E-03 Icex1, Icex2 2.00E-06 ±3.80E-09 An ISO 9001:2008 and DSCC Certified Company 52 TID Report 11-425 111109 R1.2 Aeroflex RAD 5017 N. 30th Street Colorado Springs, CO 80919 (719) 531-0800 Appendix D: List of Figures Used in the Results Section (Section 5) 5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7. 5.8. 5.9. 5.10. 5.11. 5.12. 5.13. 5.14. 5.15. 5.16. 5.17. 5.18. 5.19. 5.20. Positive Supply Current (A) @ VS=±15V Negative Supply Current (A) @ VS=±15V Input Offset Voltage 1 (V) @ VS=±15V, VCM=0V Input Offset Voltage 2 (V) @ VS=±15V, VCM=0V Input Offset Current 1 (A) @ VS=±15V, VCM=0V Input Offset Current 2 (A) @ VS=±15V, VCM=0V Positive Bias Current 1 (A) @ VS=±15V, VCM=0V Positive Bias Current 2 (A) @ VS=±15V, VCM=0V Negative Bias Current 1 (A) @ VS=±15V, VCM=0V Negative Bias Current 2 (A) @ VS=±15V, VCM=0V Large signal Voltage Gain 1 (V/mV) @ VS=±15V, VCM=0V Large signal Voltage Gain 2 (V/mV) @ VS=±15V, VCM=0V Common Mode Rejection Ratio 1 (dB) @ VS=±15V Common Mode Rejection Ratio 2 (dB) @ VS=±15V Saturation Voltage 1 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA Saturation Voltage 2 (V) @ +VS = +4.5V, -VS=0V, VIN=-6mV, ISINK = 3.2mA Saturation Voltage 1 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA Saturation Voltage 2 (V) @ VS = ±15V, VIN=-5mV, IOUT = 25mA Output Leakage Current 1 (A) @ VIN=5mV, VOUT to -VS=35V Output Leakage Current 2 (A) @ VIN=5mV, VOUT to -VS=35V An ISO 9001:2008 and DSCC Certified Company 53