Model F Subminiature, Low Profile Pressure Transducer3 DESCRIPTION Honeywell includes a full line of subminiature pressure All units have four (4) active bonded strain gages arranged in a transducers to accurately measure pressure ranges from 10 psig Wheatstone-bridge configuration. to 3000 psig. These subminiature pressure transducers have a high natural frequency and utilize a flush diaphragm. Most are manfuactured with a unitized stainless steel diaphragm. The advantage of this type of design is that a thin diaphragm Temperature compensation is accomplished by using and heavy sidewalls are made from one piece of stainless steel. temperature-sensitive components located inside the This unitized diaphragm is rugged, but at the same time it is thin transducers. These transducers have a small electrical zero enough to measure low pressures. balance circuit board which is in the leadwire (appoximately 1 in x 0.087 in thick). This balance board does not have to be the same temperature as the transducer. FEATURES • 10 psig to 3000 psig range • mV/V output • Low profile design • Subminiature footprint • High frequency • 1 % accuracy • CE approved Model F PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS Characteristic Measure Characteristic Measure Pressure ranges 10, 15, 25, 30, 50, 75, 100, 150, 200, 250, 300, 400, 500, 600, 750, 1000, 1500, 2000, 2500, 3000 psig2 Media Gas, liquid, not conductive Overload, safe (10 psig to 100 psig) 100 % over capacity Accuracy1 1.0 % full scale Linearity (10 psig to 100 psig) ±0.5 mV Overload, safe (150 psig to 3000 psig) 50 % over capacity Linearity (150 psig to 3000 psig) ±1.0 % full scale Wetted parts material (10 to 100 psig) 17-4 PH stainless steel or BeCu Hysteresis (10 psig to 100 psig) ±0.5 mV Wetted parts matl (150 to 3000 psig) 17-4 PH stainless steel Hysteresis (150 psig to 3000 psig) ±1.0 % full scale Case material Stainless steel Non-repeatability (10 psig to 100 psig) ±0.1 mV Non-repeatability (150 to 3000 psig) ±0.1 % full scale Range Code Available ranges Range Code Available ranges Output (10 psig to 100 psig) 2 mV/psi to 5 mV/psi (@ 5 Vdc) AV 10 psig CP 300 psig BJ 15 psig CQ 400 psig Output (150 psig to 3000 psig) 2 mV/V BL 25 psig CR 500 psig Resolution Infinite BM 30 psig CS 600 psig BN 50 psig CT 750 psig BP 75 psig CV 1000 psig Measure BR 100 psig DJ 1500 psig -54 °C to 149 °C [-65 °F to 300 °F] (-29 °C to 121 °C [-20 °F to 250 °F] for semiconductor strain gage) CJ 150 psig DL 2000 psig CL 200 psig DM 2500 psig CN 250 psig DN 3000 psig ENVIRONMENTAL SPECIFICATIONS Characteristic Temperature, operating Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F] Temp effect, zero (10 to 100 psig) 0.02 mV/°F Temp effect, zero (150 to 3000 psig) 0.01 % full scale/°F Temp effect, span (10 to 100 psig) 0.03 mV/°F Temp effect, span (150 to 3000 psig) 0.02 % reading/°Ft RANGE CODES OPTION CODES Range Code Pressure ranges 10, 15, 25, 30, 50, 75, 100, 150, 200, 250, 300, 400, 500, 600, 750, 1000, 1500, 2000, 2500, 3000 psig Temperature compensation 1a. 60 °F to 160 °F 1b. 30 °F to 130 °F 1c. 0 °F to 185 °F 1f. 70 °F to 250 °F 1d. -20 °F to 130 °F 1e. -20 °F to 200 °F 1g. 70 °F to 325 °F 1i. -65 °F to 250 °F Internal amplifiers 2u. Unamplified, mV/V output Electrical termination Four twisted leads 1.83 m [5 ft] ELECTRICAL SPECIFICATIONS Characteristic Measure Strained gage type (10 to 100 psig) Bonded semiconductor Strained gage type (150 to 3000 psig) Bonded foil Excitation (calibration) 5 Vdc Bridge resistance (10 to 100 psig) 500 ohm Bridge resistance (150 to 3000 psig) 350 ohm Shunt calibration data Included Electrical termination (std) Four twisted leads (1.83 m [5 ft]) with external balance board 2 Honeywell • Sensing and Control Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Subminiature, Low Profile Pressure Transducer3 MOUNTING DIMENSIONS AND CHARACTERISTICS Order code Foil/ Semiconductor Range A T L BP340 Foil 150 psig to 500 psig 6,96 mm [0.275 in] 1,07 mm [0.042]* 12,7 mm [0.50 in] BP341 Foil 150 psig to 3000 psig 8,13 mm [0.320 in] 1,07 mm [0.042]* 12,7 mm [0.50 in] BP342 Foil 150 psig to 3000 psig 10,8 mm [0.425 in] 1,52 mm [0.060] 14,22 mm [0.56 in] BP343 Semicon- 15 psig to 500 psig 3,81 mm [0.150 in] 1,07 mm [0.042] 12,7 mm [0.50 in] BP344 Semicon- 10 psig to 500 psig 6,96 mm [0.275 in] 1,07 mm [0.042] 12,7 mm [0.50 in] BP345 Semicon- 10 psig to 3000 psig 8,13 mm [0.320 in] 1,07 mm [0.042] 12,7 mm [0.50 in] BP346 Semicon- 10 psig to 3000 psig 10,8 mm [0.425 in] 1,52 mm [0.060] 14,22 mm [0.56 in] ductor ductor ductor ductor TYPICAL SYSTEM DIAGRAM * Nominal Special requirements (consult factory) Transducers have a small electrical balance circuit board (approximately 1.0 in long by 0.38 in wide) located in the lead wire that is two feet from the transducer body. Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling +1 614-850-5000 (800-848-6564). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. For reference only WIRING CODES Wire Cable/unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output Honeywell • Sensing and Control 3 Model F NOTES Subminiature, Low Profile Pressure Transducer3 1. Accuracies stated are expected for best-fit straight line for all errors, including linearity, hysteresis & non-repeatability thru zero. 2. Low pressure ranges (10 psig to 100 psig) - semiconductor gage (500 ohm); high pressure ranges (150 psig to 3000 psig) - Foil gages (350 ohm). 3. All model Fs have a cemented diaphragm. 4. Only available with foil strain gage. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to [email protected] WARNING PERSONAL INJURY •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008602-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved.