Designed and Manufactured in Germany Specification Oscillator type: Rev.: 2 AXPLO10 Phase-Locked 10 MHz OCXO (PLOCXO) Parameter Delivers a low noise output from a 10 MHz reference input signal min. typ. max. Unit Condition Nominal output frequency fOUT Frequency stability (free running) frequency tolerance vs. operating temperature range vs. supply voltage variation (pushing) vs. load change (pulling) Long term (aging) per day Long term (aging) per year Reference input Input frequency fREF Frequency accuracy Signal waveform Input level Input impedance RF output Signal waveform Load RL Amplitude Harmonics Phase noise Lock detect (LD) output Supply voltage VS Current consumption (warm-up) Current consumption (steady state) Operating temperature range 10.000 ±1 MHz Note 2 ±2 ±10 ±2 ±2 ±1 ±50 ppm ppb ppb ppb ppb ppb VS ±5% RL ±5% after 30 days operation after 30 days operation ±0.5 MHz ppm 10.000 Note 3 Sine wave 0 +13 dBm Ω 50 Sine wave 50 +7 3.5 11.4 -10 -30 Consult factory 0 1.5 5 12.0 12.6 450 200 +60 54x40x19 Enclosure (see drawing) (LxWxH) Weight Packing Notes: 1. 2. 3. 4. 5. 6. Date: 2014-06-20 60 Ω dBm dBc V V V mA mA °C mm g ±5% Note 4 Note 5 Out of lock Locked Note 6 @ +25°C h = 2.0 Palette Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Other output frequency on request with fOUT = fREF·M or fOUT = fREF·M/N Other input frequency on request Higher output level (up to 15 dBm) on request To be optimized to application w.r.t to phase noise Other supply voltage on request Absolute Maximum Ratings Parameter min. max. Unit Condition Supply Voltage VS Reference Input Level Storage Temperature -0.5 -55 VS + 10% +15 +125 V dBm °C VS to GND GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXPLO10 Rev.2 Drawing D0 Page 1(3) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Ordering Code Model Input Frequency [MHz] Output Frequency [MHz] Revision AXPLO10 10.000 Example: AXPLO10-10.000-10.000_Rev.2 10.000 Rev.2 Enclosure drawing Pin connections: Pin # Symbol 1 LD 2 GND 3 VS SMA1 RF OUT SMA2 FREF Function Lock Detect Output Ground Supply Voltage RF Output Reference Frequency Input GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXPLO10 Rev.2 Drawing D0 Page 2(3) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Handling and Testing Parameter Procedure Handling and Testing Processing Source Application Note AXAN-011 Application Note AXAN-012 Parameter Procedure Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS- Compliant IEC60749-26 IEC60749-27 Yes Yes www.axtal.com www.axtal.com Condition HBM MM No No 2000 V 200 V Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] 1 1 2 D0 D1 D0 29.01.2011 01.10.2012 20.06.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks First issue Minor editorial changes Various parameters updated, environmental conditions updated, editorial changes AXPLO10 Rev.2 Drawing D0 Page 3(3) Author Checked BN BN HH BN BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]