MPM-04 Datasheet - Micropower Direct

MPM-04 Series
Compact, Board Mount 4W
Single And Dual Output
AC/DC Power Supplies
Key Features:
• 4W Output Power
• Miniature Size
• Universal 90-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Single and Dual Outputs
• Meets EN 55022 B
• >350 kHour MTBF
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Input Voltage Range
Input Frequency
Input Current
Inrush Current
EMI
EMC
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation, See Note 3
Load Regulation, Single Output
Load Regulation, Single Output
Load Regulation, Dual Output
Load Regulation, Dual Output
Ripple/Noise (20 MHz)
Ripple/Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, See Note 4
Overload Protection
General
Parameter
Isolation Voltage
Isolation Resistance
EMI/RFI
EMC Compliance
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Safety Class
Min.
Typ.
90
120
47
See Model Selection Guide
115 VAC
15.0
230 VAC
25.0
Meets CISPR Pub. 22/FCC Class B
Meets EN 55024
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Note 2
±2.0
VIN = Min to Max
±0.2
3.3V to 5V output, IO = 0% to 100%
±1.0
9V to 24V output, IO = 0% to 100%
±0.5
Vout 1, IO = 10% to 100%
±0.5
Vout 2, IO = 10% to 100%
±5.0
Single 3.3V & 5V Outputs
100.0
All Other Models
150.0
115 VAC
15
±0.02
Zener Diode Clamp
120
Continuous (Autorecovery)
105
120
Conditions
Input to Output
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Min.
3,000
100
Typ.
Max.
264
370
440
Units
VAC
VDC
Hz
A Pk
Max.
Units
%
%
%
%
%
%
mVP-P
mVP-P
mSec
%/°C
% of VO
% of IO
Max.
Units
VAC
M⍀
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
132
kHz
Conditions
Min.
Typ.
Max.
-40
+25
+70
-40
+125
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Units
°C
°C
%
1.44 x 1.06 x 0.67 Inches (36.5 x 27.0 x 17.1 mm)
Non-Conductive Plastic & Fiberglass (UL94-V0)
0.91 Oz (26g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
350
UL 60950, EN 60950
UL, cUL; File No. E245422
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MPM-04S-03
MPM-04S-05
MPM-04S-08
MPM-04S-09
MPM-04S-12
MPM-04S-14
MPM-04S-15
MPM-04S-24
MPM-04D-0503
MPM-04D-0805
MPM-04D-1205
Output 1 (See Note 1)
Output 2 (See Note 1)
Maximum
Efficiency
Output
Maximum
Maximum
Current (A)
Current
(mA)
Current
(mA)
Voltage
Voltage
Power
(%, Typ)
Cap. Load
Cap. Load
(VDC)
(W)
115 VAC 230 VAC (VDC)
Max.
Min.
Max.
Min.
(µF)
(µF)
0.095
0.065
3.3
1.200
0.0
14,000
3.96
68
0.095
0.065
5.0
800
0.0
8,000
4.0
72
0.095
0.065
8.0
500
0.0
2,700
4.0
76
0.095
0.065
9.0
444
0.0
2,400
4.0
76
0.095
0.065
12.0
333
0.0
1,000
4.0
77
0.095
0.065
14.0
286
0.0
750
4.0
78
0.095
0.065
15.0
267
0.0
700
4.0
77
0.095
0.065
24.0
167
0.0
220
4.0
77
0.095
0.065
+5.0
+600
0.0
5,600
+3.3
+150
0.0
4,700
3.5
73
0.095
0.065
+8.0
+375
0.0
1,000
+5.0
+120
0.0
4,700
3.6
77
0.095
0.065
+12.0
+250
0.0
330
+5.0
+120
1.0
4,700
3.6
77
Notes:
1. For dual output models, Output 1 is +Vo and Output 2 is +Vr. A
47 µF/25V ceramic capacitor must be connected from +Vo (pin 12)
of dual output models to Common (pin 11). Without this capacitor,
the unit may not meet all specifications.
2. For dual output models, output voltage accuracy is specified as
±2% for +Vo and ±5% for +Vr.
3. For dual output models, line regulation is specified as ±0.2% for
+Vo and ±3% for +Vr.
4. Output short circuit protection is provided by a “hiccup mode”
circuit. The unit recovers automatically when the fault condition
is removed.
5. Operation at under no load conditions will not damage these units.
It is recommended that the minimum load values in the table above
be used.
6. It is recommended that a fuse be used on the input of a
power supply for protection. For the MPM-04 series, a
3.15A/250 VAC slow blow should be used.
Mechanical Dimensions
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Derating Curve
Pin Connections
Pin Single
Dual
1
NC
NC
7
AC-Neutral
9
AC-Line
10
NC
+Vr
11
-Vo
Common
12
+Vo
+Vo
18
NC
NC
NC = No Connection
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]