ELN-30 series 30W Single Output Switching Power Supply MODEL:ELN-30-24 OUTPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RIPPLE & NOISE V1: 150 I/P: 230VAC mVp-p (Max ) RESULT VERDICT V1: 38 mVp-p (Max ) O/P: 100% LOAD Ta:25℃ 2 OUTPUT VOLTAGE CH1: 21.6V~ 26.4V ADJUST RANGE P I/P: 230 VAC 20.1V~ 27.55 V/ 230 VAC I/P: 115 VAC 20.1V~ 27.55 V/ 115 VAC O/P:MIN LOAD Ta:25℃ 3 OUTPUT CURRENT CH1:0.9375 A~1.2875 A ADJUST RANGE 4 OUTPUT VOLTAGE V1: 5 %~ -5 % (Max) LINE REGULATION 0.18 A~ 1.69 A/ 230 VAC I/P: 115 VAC Ta:25℃ 0.18 A~ 1.67 A/ 115 VAC V1: 0.21 % -0.21 I/P: 100 VAC / 264 VAC TOLERANCE 5 I/P: 230 VAC O/P: 100% LOAD / MIN Ta:25℃ V1: 1 %~ -1 % (Max) P % LOAD I/P: 100VAC ~ 264 VAC P V1: 0 %~ -0.03 % O/P: 100% LOAD Ta:25℃ 6 LOAD REGULATION V1: 2%~ -2 % (Max) I/P: 230 VAC P V1: 0.16 %~ -0.21 % O/P: 100% LOAD ~MIN LOAD Ta:25℃ 7 SET UP TIME P 230VAC: 500 ms (Max) I/P: 230 VAC 230VAC/ 319 ms 115 VAC: 1000 ms (Max) I/P: 115 VAC 115VAC/ 640 ms P O/P: 100% LOAD Ta:25℃ 8 RISE TIME 230VAC: 50 ms (Max) I/P: 230 VAC 230VAC/ 15 ms 115VAC: 50 ms (Max) I/P: 115 VAC 115VAC/ 16 ms P O/P: 100% LOAD Ta:25℃ 9 HOLD UP TIME 230VAC: 50 ms (TYP) I/P: 230 VAC 230VAC/ 101.8 Ms 115VAC 16 ms (TYP) I/P: 115 VAC 115VAC/ 22 ms TEST: <5 % P O/P:FULL LOAD Ta:25℃ 10 OVER/UNDERSHOOT TEST I/P: 230 VAC < +5% O/P: 100% LOAD Ta:25℃ 11 DYNAMIC LOAD V1: 2400 mVp-p P I/P: 230 VAC P 290 mVp-p O/P: 100% LOAD /Min LOAD P 90%DUTY/1KHZ Ta:25℃ Model: ELN-30-24 Test Report 1 / 5 ELN-30 series 30W Single Output Switching Power Supply INPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT INPUT VOLTAGE RANGE 90VAC~264 VAC I/P:TESTING 44V~264V VERDICT O/P: 100% LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V= 87V P HIGH-LINE+15%=300 V O/P: 100% LOAD /MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 3 INPUT FREQUENCY RANGE 47HZ ~63 HZ I/P: 90 VAC ~ 264 VAC NO DAMAGE OSC O/P: 100% LOAD ~MIN LOAD Ta:25℃ 85 % (TYP) EFFICIENCY I/P: 230 VAC TEST: OK P 85.2 % O/P: 100% LOAD Ta:25℃ 4 INPUT CURRENT P 230V/ 0.48 A (TYP) I/P: 230 VAC I= 0.31 A/ 230 VAC 115V/ 0.75 A (TYP) I/P: 115 VAC I= 0.5 A/ 115 VAC I= 46.2 A/ 230 VAC P O/P: 100% LOAD Ta:25℃ 5 INRUSH CURRENT 230V/ 60 A (TYP) O/P: 100% LOAD Ta:25℃ COLD START 6 LEAKAGE CURRENT < 0.25 I/P: 230 VAC mA / 240 VAC P I/P: 264 VAC L-FG: 0.01 mA O/P:Min LOAD Ta:25℃ N-FG: 0.01 mA P PROTECTION FUNCTION TEST NO 1 2 TEST ITEM SPECIFICATION TEST CONDITION RESULT OVER LOAD PROTECTION 95 %~110 % I/P: 230 VAC 103 %/ 230 VAC I/P: 115 VAC 103 %/ 115 VAC O/P:TESTING Ta:25℃ Constant Current Limiting I/P: 230 VAC 31 V/ 230 VAC I/P: 115 VAC 31 V/ 115 VAC OVER VOLTAGE PROTECTION CH1: 28V~ 32V O/P:MIN LOAD Ta:25℃ 3 SHORT PROTECTION VERDICT P P Shunt down Re- power ON SHORT EVERY OUTPUT I/P: 264 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P: 100% LOAD Ta:25℃ Constant Current Limiting P Model: ELN-30-24 Test Report 2 / 5 ELN-30 series 30W Single Output Switching Power Supply ENVIRONMENT TEST NO 1 TEST ITEM SPECIFICATION TEMPERATURE RISE TEST MODEL:ELN-30-24 TEST CONDITION RESULT VERDICT 1. ROOM AMBIENT BURN-IN:1.5 HRS I/P: 230VAC O/P: 100% LOAD Ta= 30.2 ℃ 2. HIGH AMBIENT BURN-IN:2.5 HRS I/P: 230VAC O/P: 100% LOAD Ta= 40.6 ℃ 2 OVER LOAD BURN-IN TEST P/N ROOM AMBIENT HIGH AMBIENT Ta= 30.2 ℃ Ta= 40.6 ℃ 77.5℃ 85.6℃ NO Position 1 BD1 KBP208G 2A/800V 2 C5 68U/400V 105℃ KM 65.4℃ 73.3℃ 3 C36 100U/35V 105℃ KF 66.1℃ 74.0℃ 4 ZD1 P6KE200A 83.4℃ 91.4℃ 5 T1 COIL TF-1613 92.4℃ 100.1℃ 6 D1 IN4007GP 1A/1KV 92.7℃ 100.8℃ 7 Q1 2SK2645 9A/600V 92.0℃ 99.9℃ 8 D4 1N4007GP 1A/1KV 73.8℃ 81.6℃ FMX-12SL 10A/200V 66.8℃ 74.9℃ 330U/35V 105℃ KF 71.1℃ 79.0℃ 56.2℃ 64.3℃ 9 D100 10 C105 11 L100 12 U1 NCP1200D60R2G 61.3℃ 69.3℃ 13 INSIDE TA UP SCR1 77.9℃ 85.9℃ 14 PCB T1 BETWEEN D4 83.3℃ 90.9℃ RB010E-R2 NO DAMAGE 1.2Φ 0.5uH I/P: 230 VAC O/P: 118 ﹪LOAD 1 HOUR ( MIN ) P TEST:OK P Ta:25℃ 3 LOW TEMPERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/P: 230 VAC O/P: 100 ﹪LOAD TEST:OK P Ta= -20 ℃ 4 AFTER 12 HOURS I/P: 272 VAC HIGH TEMPERATURE IN CHAMBER ON CONTROL 40℃ O/P: 100% LOAD Ta= 40℃ NO DAMAGE + 0.03 %(0~50℃) I/P: 230 VAC HIGH VOLTAGE TURN ON TEST 5 TEMPERATURE VIBRATION TEST HUMIDITY= P 95 %R.H + 0.012 %(0~50℃) P O/P:100% LOAD COEFFICIENT 6 TEST:OK HIGH HUMIDITY 1 Carton & 1 Set TEST:OK (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle P (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) Ta:25℃ Model: ELN-30-24 Test Report 3 / 5 ELN-30 series 30W Single Output Switching Power Supply SAFETY TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 3 KVAC/min I/P-O/P: 3.6KVAC/min Ta:25℃ I/P-O/P: VERDICT 1.87 mA P NO DAMAGE 2 ISOLATION RESISTANCE I/P-O/P:500VDC>100MΩ I/P-O/P: 500 Ta:25℃ VDC I/P-O/P: 30 GΩ P NO DAMAGE 3 APPROVAL TUV: Certificate NO : N/A UL: File NO : E.M.C TEST NO 1 2 3 4 5 TEST ITEM SPECIFICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P: 230 VAC/50HZ PASS CLASS A O/P: 100% LOAD Ta:25℃ EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P: 100% LOAD /50% LOAD Ta:25℃ Test by certified Lab CONDUCTION RADIATION E.S.D E.F.T 6 SURGE P EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P: 100% LOAD Ta:25℃ Test by certified Lab EN61000-4-2 I/P: 230 VAC/50HZ CRITERIA A LIGHT INDUSTRY AIR:8KV / Contact:4KV O/P: 100% LOAD Ta:25℃ EN61000-4-4 I/P: 230 VAC/50HZ LIGHT INDUSTRY O/P: 100% LOAD Ta:25℃ INPUT: 1KV IEC61000-4-5 I/P: 230 VAC/50HZ LIGHT INDUSTRY O/P: 100% LOAD Ta:25℃ L-N :1KV VERDICT P P P CRITERIA A P CRITERIA A P L,N-PE:2KV 7 Test by certified Lab & Test Report Prepare M.T.B.F & LIFE CYCLE CALCULATION NO 1 TEST ITEM SPECIFICATION CAPACITOR ELN-30-24 : SUPPOSE C105 IS THE MOST CRITICAL COMPONENT I/P: 230VAC O/P: 100% LOAD Ta= 25 ℃ LIFE TIME= 94508 HRS LIFE CYCLE 2 3 I/P: 230VAC O/P: 100% LOAD I/P: 230VAC O/P: 75% LOAD TEST CONDITION Ta= 40 ℃ Ta= 40 ℃ RESULT VERDICT P LIFE TIME=39740 HRS LIFE TIME= 78411 HRS MTBF MIL-HDBK-217F NOTICES2 PARTS COUNT DMTBF/Accelerated Life Test TOTAL FAILURE RATE: 628.3K HRS Demonstration Mean Time Between Failure(Expected Life) : 20,000 hours @ Tcase 80℃; 50,000 hours @ Tcase 65℃ P P Model: ELN-30-24 Test Report 4 / 5 ELN-30 series 30W Single Output Switching Power Supply COMPONENT STRESS TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT Power Transistor Q1 Rated 2SK2645-01MR 9A/600V I/P:High-Line +3V = 267 V (1) 512 V O/P: (1) 100% LOAD Turn on (2) 438 V I/P:High-Line +3V = 267 V (1) 156 V O/P: (1) 100% LOAD Turn on (2) 133 V (1) 472 V ( D to S) or (C to E) Peak Voltage VERDICT P (2) Output Short Ta:25℃ 2 Diode Peak Voltage D100 Rated FMX-12SL 10A/200V P (2)Output Short Ta:25℃ 3 Clamp Diode Peak Voltage D1 Rated 1A/1KV 1N4007GP I/P:High-Line +3V = 267 V O/P: (1) Dynamic Load 90%Duty/1KHz P Ta:25℃ 4 Input Capacitor Voltage C5 Rated 68u/400V 105℃ I/P:High-Line +3V = 267 V (1) 384 V O/P: (1)Full Load Turn on /Off (2) 388 V (2) Min load Turn on /Off (3) 388 V P (3)Full Load /Min load Change Ta:25℃ 5 Control IC Voltage Test U1 Rated NCP1200D60R2G:16V I/P:High-Line +3V = 267 V (1) 11.83 V O/P: (1) 100% LOAD Turn on /Off (2) 10.23 V (3) 11.83 V (2) Min load Turn on /Off P (3) 100% /Min load Change Ta:25℃ DATE SAMPLE TEST RESULT TESTER APPROVAL 2007/10/15 RD SAMPLE PASS VINCENT TSENG MAX LIN PASS VINCENT TSENG MAX LIN PASS SANFORD SU VINCENT TSENG 2007/11/27 2008/1/10 PRODUCT SAMPLE W0710E49 PRODUCT SAMPLE W0712C07 2003/12/12 Model: ELN-30-24 A50-F023 Test Report 5 / 5