LP-Series Datasheet

LP-Series
Illuminated Indicators
The LP-Series Illuminated Indicators are the perfect complement to the aesthetics,
reliability and performance of our L-Series rocker switches. As a critical safety
feature, the illumination alerts the operator of essential system functions or
malfunctions, such as: Oil Pressure, High Temperature, Transmission or other fluid
levels, Parking Brake or General System confirmations. The L-Series styling assures
seamless integration into most any dashboard panel to meet the needs of today’s
Off Highway, Heavy Vehicle, Marine, Appliance and Industrial Control markets.
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: [email protected]
Application Support: [email protected]
Phone: (860) 793-9281 • Fax: (860) 793-9231
www.carlingtech.com
2 | LP-Series Illuminated Indicators - General Specifications
Electrical
Terminals
Brass or copper/silver plate
3/16” (4.76mm) & 1/4” (6.3mm)
Quick Connect terminations standard.
Lighted
Incandescent - rated 10,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for voltages to 24VDC)
Physical
Seals
Base
Insert
Connector
Markings
Bracket
Insert, base & bracket are sealed.
Nylon 66 GF rated to 85°C with a flammability rating of 94VO.
Polycarbonate rated at 100°C.
Nylon 66 rated at 85°C. Polarized
Over 1000 pad printed or laser etched legends available
Nylon 66 GF rated to 85°C
Environmental
Environmental
IP67, representing an index of
protection as applied to electrical equipment in accordance with IEC 529, BS 5490, DIN 400 50 &
NFC 20 010.
Corrosion Resistance Mixed Flowing Gas MFG Class III per ASTM B-827 & B-845, Method H, with 3 years exposure.
Operating Temperature -40°C to +85°C
Vibration 1
Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10-
500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance.
Vibration 2
Resonance search
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s max.
Random
24 Hz
0.06 PSD-Gsq/Hz
60 Hz
0.50
100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10µ chatter.
Shock
Per Mil-Std 202F, Method 213B, Test Condition K @ 30G’s. Tested with VCH connector. Test criteria - No loss of circuit during test, pre, and post test contact resistance.
Salt Spray
Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs.
Thermal Shock
Per Mil-Std 202F, Method 107F, Test Condition A, -55°C to 85°C. Test criteria - pre and post test contact resistance.
Moisture Resistance
Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance.
*Manufacturer reserves the right to change product specification without prior notice.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
LP-Series Illuminated Indicators - Ordering Scheme | 3
LP 1 H R R 5
1
Series
2
3
Termination Illumination
4
Lamp
5
Lamp
6
Bracket
Color
.250 (8.35) x .032 (0.51) Quick Connect
.187 (4.75) x .032 (0.51) Quick Connect
3 ILLUMINATION
LAMPS
1
1
2
1
2
1 & 2
1 & 2
ILLUMINATION
–
–
–
–
–
Parallel
Series
LAMP WIRED TO TERMINALS
10 (+) 8 (–)
10 (+) 8 (–) 12 (+) 11 (–)
10 (+) 8 (–) 12 (+) 8 (–)
10 (+) 8 (–)
10 (+) 8 (–)
LAMP 1 LOCATED ABOVE TERMINALS 9 & 10 END OF BRACKET.
LAMP 2 LOCATED ABOVE TERMINALS 11 & 12 END OF BRACKET.
POSITIVE (+) AND NEGATIVE (–) SYMBOLS APPLY TO LED LAMPS ONLY.
No lamp0 (position 5 only)
Incandescent 4 3V 5 6V LED
Amber
Green
2VDC
L
F
6VDC
M G
12VDC
N
H
24VDC
P
J
Black
12
Legend 2
6 12V Red
R
S
T
V
8, 9 STYLE (same coding for both selections)
Z 5 A
Not Painted (used with INSERT COLORS A-F)
Clear Laser Etch Background Color (used with INSERT COLOR 9)
White Laser Etch Background Color (used with INSERT COLOR 9)
10 LEGEND OVER LAMP1
00
No legend
__
Laser Etched or Body Legends
For legend options, visit us at carlingtech.com
0
1
2
3
4
Selection 4: specifies lamp 1 located above terminals 10 (+) & 9 (-).
Selection 5: specifies lamp 2 located above terminals 12 (+) & 11 (-).
5
1 DU
11
Legend
Orientation
11 LEGEND ORIENTATION
4,5 LAMP (same coding for both selections)2
6 BRACKET COLOR
10
Legend 1
9
Style
9
Painted Black - Laser Etch
A
Clear (Transparent)
B
White (Translucent)
C
Red (Translucent)
D
Amber (Translucent)
E
Green (Translucent)
F
Blue (Translucent)
2 TERMINATION3
A
B
C
E
H
8
Style
7 INSERT COLOR1,2
1 SERIES
LP L-Series Illumination Plug
1
3
9 A A Y2
7
Insert
Color
7 18V 8 24V
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
4F
MC
MA
4F100
MA
MC
MA3MC
MA1MC
12 LEGEND OVER LAMP2
00
No legend
__
Laser Etched or Body Legends
For legend options, visit us at carlingtech.com
Notes:
1 To order separately, specify LPC and selection 7 code. Ex LPC-9
2 For LEDs, insert color must be clear, white or match color of LED.
3 For connector, specify part number LC2-01 (.187 tabs), LC3-01 (.250 tabs).
REV_SW_LP_08_2014
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com