PDL02 SERIES

PDL02 SERIES
DC-DC CONVERTER
2:1 WIDE INPUT RANGE
UP TO 2 Watts
FEATURES
APPLICATIONS
• NO MINIMUM LOAD REQUIRED
• UP TO 3000VDC INPUT TO OUTPUT ISOLATION
• SMALL SIZE AND LOW PROFILE 0.86 X 0.36 X 0.44 INCH
• LOW OUTPUT RIPPLE AND NOISE
• UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• DISTRIBUTED POWER ARCHITECTURES
• SEMICONDUCTOR EQUIPMENT
:
3000VDC
ISOLATION
1600VDC
ISOLATION
REMOTE
CONTROL
OCP
SCP
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted
Model
Number
PDL02-05S33
PDL02-05S05
PDL02-05S09
PDL02-05S12
PDL02-05S15
PDL02-05D05
PDL02-05D12
PDL02-05D15
PDL02-12S33
PDL02-12S05
PDL02-12S09
PDL02-12S12
PDL02-12S15
PDL02-12D05
PDL02-12D12
PDL02-12D15
PDL02-24S33
PDL02-24S05
PDL02-24S09
PDL02-24S12
PDL02-24S15
PDL02-24D05
PDL02-24D12
PDL02-24D15
PDL02-48S33
PDL02-48S05
PDL02-48S09
PDL02-48S12
PDL02-48S15
PDL02-48D05
PDL02-48D12
PDL02-48D15
1
Input Range
Output Voltage
Output Current
@Full Load
Input Current
@ No Load
Efficiency
Maximum
Capacitor Load
VDC
4.5 ~ 9
4.5 ~ 9
4.5 ~ 9
4.5 ~ 9
4.5 ~ 9
4.5 ~ 9
4.5 ~ 9
4.5 ~ 9
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
VDC
3.3
5
9
12
15
±5
±12
±15
3.3
5
9
12
15
±5
±12
±15
3.3
5
9
12
15
±5
±12
±15
3.3
5
9
12
15
±5
±12
±15
mA
500
400
222
167
134
±200
±83
±67
500
400
222
167
134
±200
±83
±67
500
400
222
167
134
±200
±83
±67
500
400
222
167
134
±200
±83
±67
mA
35
35
40
40
40
40
40
40
20
20
20
20
20
30
30
30
15
15
15
15
15
15
15
15
8
8
8
8
8
8
8
8
%
76
80
82
81
83
79
82
81
77
81
82
83
84
81
83
84
78
81
82
83
84
80
83
82
76
78
84
83
83
80
81
81
µF
2200
1000
470
170
110
±470
±100
±47
2200
1000
470
170
110
±470
±100
±47
2200
1000
470
170
110
±470
±100
±47
2200
1000
470
170
110
±470
±100
±47
www.PDUKE.com
2014/04/30
PDL02
PART NUMBER STRUCTURE
PDL02 - 48
Series Name
S
Input
Voltage
(VDC)
05: 4.5~9
12: 9~18
24:18~16
48:36~75
05
Output
Voltage
(VDC)
S:Single 33: 3.3
05: 5
09: 9
12:12
15:15
H
Output
Quantity
D: Dual
Isolation
Option
: Standard type
1600VDC isolation
H: 3000VDC isolation
05:± 5
12:±12
15:±15
INPUT SPECIFICATIONS
Parameter
Conditions
Operating input voltage range
Start up time
Constant resistive load
Input surge voltage
100 ms, max.
Input reflected ripple current
With external input capacitors
5Vin(nom)
12Vin(nom)
24Vin(nom)
48Vin(nom)
Power up
Remote ON/OFF
5Vin(nom)
12Vin(nom)
24Vin(nom)
48Vin(nom)
5Vin(nom)
12Vin(nom)
24Vin(nom)
48Vin(nom)
Input filter (1)
Remote ON/OFF
Application circuit
DC-DC ON
OUTPUT SPECIFICATIONS
Parameter
Voltage accuracy
Line regulation
Conditions
Low Line to High Line at Full Load
No Load to Full Load
10% Load to 90% Full Load
2
Max.
Unit
5
12
24
48
5
5
9
18
36
75
VDC
ms
2
VDC
400
150
mAp-p
380
170
Capacitor type
Open or high impedance
3
4
mA
2.5
mA
DC-DC OFF
Load regulation
Cross regulation
Ripple and noise
Temperature coefficient
Transient response recovery time
Short circuit protection
Typ.
4.5
9
18
36
15
36
50
100
DC-DC ON
DC-DC OFF
Remote off input current
Ctrl pin applied current via 1kΩ
Min.
Asymmetrical load 25%/100% FL
20MHz bandwidth
25% load step change
www.PDUKE.com
Min.
Single
Dual
Single
Dual
Dual
Typ.
-1.0
-0.2
-1.0
-1.0
-0.5
-0.8
-5.0
Max.
Unit
+1.0
+0.2
+1.0
+1.0
+0.5
+0.8
+5.0
%
%
%
%
%
mVp-p
-0.02
+0.02
%/
500
µs
Continuous, automatics recovery
50
℃
2014/04/30
PDL02
GENERAL SPECIFICATIONS
Parameter
Conditions
Isolation voltage
1 minute
Isolation resistance
Isolation capacitance
500VDC
Switching frequency
Safety approvals
Full load to minimum load
Case material
Base material
Potting material
Weight
MTBF
Input to Output
Min.
Standard Type
Suffix ”H”
MIL-HDBK-217F
Conditions
Min.
Without derating
With derating
Storage temperature range
Thermal shock
Vibration
Relative humidity
EMC SPECIFICATIONS
Parameter
Conditions
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Unit
GΩ
200
40
100
Operating ambient temperature
Max.
VDC
Standard Type
Suffix ”H”
ENVIRONMENTAL SPECIFICATIONS
Parameter
EMI(2)
ESD
Radiated immunity
Fast transient (3)
Surge (3)
Conducted immunity
Typ.
1600
3000
1
Air ± 8kV and Contact ± 6kV
10 V/m
± 2kV
±1kV
10 Vr.m.s
-40
+85
-55
pF
kHz
UL60950-1
EN60950-1
IEC60950-1
Non-conductive black plastic
None
Silicone (UL94 V-0)
4.8g (0.17oz)
4.903 x 106 hrs
Typ.
Max.
Unit
℃
℃
+85
+100
+125
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
Level
,
Class A Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1.
It will not damage the device without installing external input capacitors. It’s helpful to reduce input reflected ripple current if external input
capacitors are installed.
2.
The standard modules meet EMI Class A or Class B with external components. For further information, please contact with P-DUKE.
3.
An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220µF/100V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
PDL02-24S05 Derating Curve
3
PDL02-24S05 Efficiency vs. Input Voltage
www.PDUKE.com
PDL02-24S05 Efficiency vs. Output Load
2014/04/30
PDL02
MECHANICAL DRAWING
PIN CONNECTION
PIN
SINGLE
DUAL
1
-Vin
-Vin
2
+Vin
+Vin
3
Ctrl
Ctrl
5
NC
NC
6
+Vout
+Vout
7
-Vout
Common
8
NC
-Vout
*NC pin for standard type model.
**No pin for 3kVDC isolation model (suffix “H”).
1. All dimensions in inch (mm)
2. Tolerance :x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
3. Pin pitch tolerance ±0.01 (0.25)
4. Pin dimension tolerance ±0.004(0.1)
4
www.PDUKE.com
2014/04/30