FEC60 SERIES

FEC60
FEC60 SERIES
DC-DC CONVERTER
2:1 WIDE INPUT RANGE
UP TO 60Watts
FEATURES
APPLICATIONS
• NO MINIMUM LOAD REQUIRED
• 1600VDC INPUT TO OUTPUT ISOLATION
• STANDARD 2.00 X 2.00 X 0.40 INCH
• SIX-SIDED CONTINUOUS SHIELD
• UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
1600VDC
ISOLATION
REMOTE
CONTROL
UVP
OCP
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• DISTRIBUTED POWER ARCHITECTURES
• SEMICONDUCTOR EQUIPMENT
SCP
OVP
OTP
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25
Model
Number
FEC60-24S3P3
FEC60-24S05
FEC60-24S12
FEC60-24S15
FEC60-24S24
FEC60-48S3P3
FEC60-48S05
FEC60-48S12
FEC60-48S15
FEC60-48S24
otherwise noted
Input Range
Output Voltage
Output Current
@Full Load
Input Current
@ No Load
Efficiency
Maximum
Capacitor Load (1)
VDC
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
VDC
3.3
5
12
15
24
3.3
5
12
15
24
A
14
12
5
4
2.5
14
12
5
4
2.5
mA
100
130
50
50
50
80
90
30
30
30
%
89
90
90
90
89
89
91
90
90
90
µF
36000
20400
3550
2300
885
36000
20400
3550
2300
885
PART NUMBER STRUCTURE
FEC60 - 48
Series Name
1
Input
Voltage
(VDC)
24: 18~36
48: 36~75
S
Output
Quantity
S: Single
05
Output
Voltage
(VDC)
3P3: 3.3
05: 5
12: 12
15: 15
24: 24
-
N
HS
Remote Control
Option
Assembly Option
: Positive logic
N: Negative logic
www.PDUKE.com
: No assembly
HS: Heat-sink
HC: Heat-sink with Clamp
2015/2/26
FEC60
INPUT SPECIFICATIONS
Parameter
Conditions
24Vin(nom)
48Vin(nom)
Operating input voltage range
Input reflected ripple current
Start-up voltage
Start up time
Constant resistive load
Input surge voltage
100 ms, max.
Input filter
Remote ON/OFF
Referred to –Vin pin
OUTPUT SPECIFICATIONS
Parameter
Measured by 20MHz bandwidth
2
-0.5
Min.
24Vout
Others
3.3Vout, 5Vout
12Vout, 15Vout
24Vout
Typ.
% of Iout rated
Conditions
Input to Output
Input(Output) to Case
500VDC
MIL-HDBK-217F, Full load
www.PDUKE.com
ms
VDC
mA
mA
Max.
Unit
+1.0
+0.2
+0.5
+20
+10
%
%
%
%
mVp-p
+0.02
250
3.3Vout
5Vout
12Vout
15Vout
24Vout
VDC
VDC
75
100
200
-0.02
1 minute
mAp-p
20
20
50
100
Pi type
Open or 3 ~ 12VDC
Short or 0 ~ 1.2VDC
Short or 0 ~ 1.2VDC
Open or 3 ~ 12VDC
+1.0
4.0
-1.0
-0.2
-0.5
-10
-10
25% load step change
GENERAL SPECIFICATIONS
Parameter
Case material
Base material
Potting material
Weight
MTBF
VDC
15
32
Conditions
Ripple and noise
Case grounding
Isolation resistance
Isolation capacitance
Switching frequency
Safety approvals
Unit
36
75
17
34
Positive logic
DC-DC ON
(Standard)
DC-DC OFF
Negative logic
DC-DC ON
(Option)
DC-DC OFF
Input current of Ctrl pin
Remote off input current
Low Line to High Line at Full Load
No Load to Full Load
Isolation voltage
Max.
24
48
20
24Vin(nom)
48Vin(nom)
24Vin(nom)
48Vin(nom)
Power up
Remote ON/OFF
24Vin(nom)
48Vin(nom)
Voltage accuracy
Line regulation
Load regulation
Voltage adjustability (2)
Over load protection
Short circuit protection
Typ.
18
36
Nominal input and Full load
Shutdown voltage
Temperature coefficient
Transient response recovery time
Over voltage protection
Min.
%/
µs
3.7
5.6
13.8
16.8
30.0
5.4
7.0
17.5
VDC
20.5
33.0
150
%
Continuous, automatics recovery
Min.
Typ.
Max.
Unit
1600
VDC
1600
Connect case to –Vin with decoupling Y Cap
1
GΩ
1500
pF
270
300
330
kHz
UL60950-1
EN60950-1
IEC60950-1
Nickel-coated copper
FR4 PCB
Epoxy (UL94 V-0)
60g (2.11oz)
4.089 x 105 hrs
2015/2/26
FEC60
ENVIRONMENTAL SPECIFICATIONS
Parameter
Conditions
Operating ambient temperature
Maximum case temperature
Over temperature protection
Storage temperature range
Thermal impedance
Min.
Without derating
With derating
Typ.
-40
+40
Max.
Unit
+40
+110
+110
+120
-55
Vertical direction by natural convection (20LFM)
Without heat-sink
With heat-sink
+125
10.5
8.4
/W
Thermal shock
Vibration
Relative humidity
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI (3)
ESD
Radiated immunity
Fast transient (4)
Surge (4)
Conducted immunity
Conditions
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level
Air ± 8kV and Contact ± 6kV
10 V/m
± 2kV
± 1kV
10 Vr.m.s
Class A, Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1.
2.
3.
4.
Test by minimum input and constant resistive load.
24Vout maximum output deviation is +20%,-10% inclusive of remote sense and trim. Others maximum output deviation is 10% inclusive of
remote sense and trim. If remote sense is not being used, the +Sense should be connected to its corresponding +Vout and likewise the -Sense
should be connected to its corresponding -Vout.
The standard modules meet EN55022 Class A and Class B with external components. For further information, please contact with P-DUKE.
An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Power Mate suggest:
Nippon chemi-con KY series, 220µF/100V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
3
FEC60-48S05 Derating Curve
FEC60-48S05 Derating Curve With Heat-sink
FEC60-48S05 Efficiency vs. Input Voltage
FEC60-48S05 Efficiency vs. Output Load
www.PDUKE.com
2015/2/26
FEC60
MECHANICAL DRAWING
PIN CONNECTION
PIN
1
2
3
4
5
6
7
8
SINGLE
+Vin
-Vin
Ctrl
-Sense (2)
+Sense (2)
+Vout
-Vout
Trim
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by
using the method shown below.
TRIM UP
TRIM DOWN
4
8
RU
8
RD
5
1. All dimensions in inch (mm)
2. Tolerance :x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
3. Pin pitch tolerance ±0.01 (0.25)
4. Pin dimension tolerance ±0.004(0.1)
4
www.PDUKE.com
2015/2/26