FED40 SERIES

FED40
FED40 SERIES
DC-DC CONVERTER
2:1 WIDE INPUT RANGE
UP TO 40 Watts
FEATURES
APPLICATIONS
• NO MINIMUM LOAD REQUIRED
• 1600VDC INPUT TO OUTPUT ISOLATION
• STANDARD 2.00 X 1.00 X 0.40 INCH
• SIX-SIDED CONTINUOUS SHIELD
• SAFETY MEETS UL60950-1, EN60950-1, IEC60950-1, & EN50155
• CE MARKED
• COMPLIANT TO RoHS II & REACH
1600VDC
ISOLATION
REMOTE
CONTROL
UVP
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• DISTRIBUTED POWER ARCHITECTURES
• SEMICONDUCTOR EQUIPMENT
OCP
SCP
OVP
OTP
LOW
STANDBY
POWER
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted
Model
Number
FED40-12S3P3
FED40-12S05
FED40-12S12
FED40-12S15
FED40-12S24
FED40-12D12
FED40-12D15
FED40-12D24
FED40-24S3P3
FED40-24S05
FED40-24S12
FED40-24S15
FED40-24S24
FED40-24D12
FED40-24D15
FED40-24D24
FED40-48S3P3
FED40-48S05
FED40-48S12
FED40-48S15
FED40-48S24
FED40-48D12
FED40-48D15
FED40-48D24
Input Range
Output Voltage
Output Current
@Full Load
Input Current
@ No Load
Efficiency
Maximum
Capacitor Load (1)
VDC
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
9 ~ 18
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
18 ~ 36
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
36 ~ 75
VDC
3.3
5
12
15
24
±12
±15
±24
3.3
5
12
15
24
±12
±15
±24
3.3
5
12
15
24
±12
±15
±24
mA
10000
8000
3333
2666
1666
±1666
±1333
±833
10000
8000
3333
2666
1666
±1666
±1333
±833
10000
8000
3333
2666
1666
±1666
±1333
±833
mA
20
20
20
20
20
20
20
20
15
15
15
15
15
15
15
15
10
10
10
10
10
10
10
10
%
90
91
91
91
91
90
91
91
91
92
92
92
91
90
91
91
91
92
92
92
92
91
91
90
µF
26600
20000
3900
2600
1300
± 2600
± 1600
±650
26600
20000
3900
2600
1300
± 2600
± 1600
±650
26600
20000
3900
2600
1300
± 2600
± 1600
±650
PART NUMBER STRUCTURE
FED40 Series Name
48
Input
Voltage
(VDC)
12: 9~18
24: 18~36
48: 36~75
S
Output
Quantity
S: Single
D: Dual
1
05
Output
Voltage
(VDC)
3P3: 3.3
05: 5
12: 12
15: 15
24: 24
12: ±12
15: ±15
24: ±24
-
N
HS
Remote Control
options
Heat-sink
: Positive logic
N: Negative logic
www.PDUKE.com
: No Heat-sink
HS: Heat-sink
HC: Heat-sink with Clamp
2014/4/30
FED40
INPUT SPECIFICATIONS
Parameter
Conditions
12Vin(nom)
24Vin(nom)
48Vin(nom)
12Vin(nom)
24Vin(nom)
48Vin(nom)
12Vin(nom)
24Vin(nom)
48Vin(nom)
Power up
Remote ON/OFF
12Vin(nom)
24Vin(nom)
48Vin(nom)
Operating input voltage range
Start-up voltage
Shutdown voltage
Start up time
Constant resistive load
Input surge voltage
1 second, max.
Input filter
Remote ON/OFF
Referred to –Vin pin
OUTPUT SPECIFICATIONS
Parameter
Voltage accuracy
Line regulation
Load regulation
Positive logic
DC-DC ON
(Standard)
DC-DC OFF
DC-DC ON
Negative logic
(Option)
DC-DC OFF
Input current of Ctrl pin
Remote off input current
Conditions
Low Line to High Line at Full Load
No Load to Full Load
Cross regulation
Voltage adjustability
Asymmetrical load 25%/100% FL
Single output
Ripple and noise
Measured by 20MHz bandwidth
With a 0.1µF/50V X7R MLCC
Temperature coefficient
Transient response recovery time
Over voltage protection
Over load protection
Short circuit protection
3.3Vout
5Vout
12Vout
15Vout
24Vout
% of Iout rated; Hiccup mode
Isolation voltage
1 minute
Isolation resistance
Isolation capacitance
Switching frequency
Safety meets
500VDC
2
Typ.
Max.
9
18
36
12
24
48
18
36
75
9
18
36
8
16
32
60
60
-0.5
Min.
Conditions
Input to Output
Input (Output) to Case
Typ.
-1.0
-0.2
-0.5
-1.0
-5.0
-10
-10
75
100
150
www.PDUKE.com
VDC
VDC
VDC
ms
Max.
Unit
+1.0
+0.2
+0.5
+1.0
+5.0
+10
+20
100
125
200
+0.02
%
%
%
%
%
mVp-p
℃
%/
250
µs
3.9
6.2
15
VDC
20
30
150
%
Continuous, automatics recovery
Min.
Typ.
1600
1600
1
225
MIL-HDBK-217F, Full load.
Unit
25
50
VDC
100
Pi type
Open or 3 ~ 12VDC
Short or 0 ~ 1.2VDC
Short or 0 ~ 1.2VDC
Open or 3 ~ 12VDC
0.5
mA
3
mA
-0.02
25% load step change
Zener diode clamp
GENERAL SPECIFICATIONS
Parameter
Case material
Base material
Potting material
Weight
MTBF
Single
Dual
Dual
3.3Vout, 5Vout, 12Vout
15Vout, 24Vout
3.3Vout, 5Vout
12Vout, 15Vout
24Vout
Min.
Max.
Unit
VDC
250
GΩ
pF
kHz
UL60950-1
EN60950-1
IEC60950-1
Copper
FR4 PCB
Silicone (UL94 V-0)
32g (1.13oz)
1.066 x 106 hrs
1500
275
2014/4/30
FED40
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Maximum case temperature
Over temperature protection
Storage temperature range
Thermal impedance
Conditions
Min.
Typ.
-40
Max.
+85
+105
+115
-55
Vertical direction by natural convection (20LFM)
Without Heat-sink
With Heat-sink
+125
10.8
10.3
Thermal shock
Vibration
Relative humidity
Unit
℃
℃
℃
℃
℃/W
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI (2)
ESD
Radiated immunity
Fast transient (3)
Surge (3)
Conducted immunity
Conditions
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level
Air ± 8kV and Contact ± 6kV
20 V/m
± 2kV
± 2kV
10 Vr.m.s
Class A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1.
2.
3.
Test by minimum input and constant resistive load.
The standard modules meets EMI Class A or Class B with external components. For further information, please contact with P-DUKE.
The external input components are required required if the module has to meet EN61000-4-4, EN61000-4-5.
The FED40-12 recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS
(SMDJ58A, 58V, 3000Watt peak pulse power) to connect in parallel.
The FED40-24 recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS
(SMDJ64A, 64V, 3000Watt peak pulse power) to connect in parallel.
The FED40-48 recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS
(SMDJ120A,120V, 3000Watt peak pulse power) to connect in parallel.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
FED40-48S05 Derating Curve
FED40-48S05 Derating Curve with Heat-sink
FED40-48S05 Efficiency VS Input Voltage
FED40-48S05 Efficiency VS Output Load
MECHANICAL DRAWING
3
www.PDUKE.com
2014/4/30
FED40
PIN CONNECTION
PIN
SINGLE
1
+ Vin
2
- Vin
3
Ctrl
4
+ Vout
5
- Vout
6
Trim
DUAL
+ Vin
- Vin
Ctrl
+ Vout
Common
- Vout
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the method
shown below.
1. All dimensions in inch (mm)
2. Tolerance :x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
3. Pin pitch tolerance ±0.01 (0.25)
4. Pin dimension tolerance ±0.004(0.1)
4
www.PDUKE.com
2014/4/30