FED40W SERIES - RSG Electronic Components GmbH

FED40W
FED40W SERIES
DC-DC CONVERTER
4:1 WIDE INPUT RANGE
UP TO 40Watts
FEATURES
APPLICATIONS
• NO MINIMUM LOAD REQUIRED
• LOW STANDBY POWER CONSUMPTION
• 1600VDC INPUT TO OUTPUT ISOLATION
• SIX-SIDED CONTINUOUS SHIELD
• STANDARD 2.00 X 1.00 X 0.40 INCH
• SAFETY MEETS UL60950-1, EN60950-1 IEC60950-1 AND EN50155
• CE MARK MEETS 2006/95/EC, 2011/95/EC and 2004/108/EC
• COMPLIANT TO RoHS EU DIRECTIVE 2011/65/EU
1600VDC
ISOLATION
REMOTE
CONTROL
UVP
RAILWAY SYSTEM
WIRELESS NETWORK
TELECOM/DATACOM
INDUSTRY CONTROL SYSTEM
DISTRIBUTED POWER ARCHITECTURES
SEMICONDUCTOR EQUIPMENT
OCP
SCP
OVP
OTP
LOW
STANDBY
POWER
TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted
Model
Number
FED40-24S3P3W
FED40-24S05W
FED40-24S12W
FED40-24S15W
FED40-24S24W
FED40-24D12W
FED40-24D15W
FED40-24D24W
FED40-48S3P3W
FED40-48S05W
FED40-48S12W
FED40-48S15W
FED40-48S24W
FED40-48D12W
FED40-48D15W
FED40-48D24W
FED40-110S3P3W
FED40-110S05W
FED40-110S12W
FED40-110S15W
FED40-110S24W
FED40-110D12W
FED40-110D15W
FED40-110D24W
Input Range
Output Voltage
Output Current
@Full Load
Input Current
@ No Load
Efficiency
Maximum
Capacitor Load
VDC
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
VDC
3.3
5
12
15
24
±12
±15
±24
3.3
5
12
15
24
±12
±15
±24
3.3
5
12
15
24
±12
±15
±24
mA
10000
8000
3333
2666
1666
±1666
±1333
±833
10000
8000
3333
2666
1666
±1666
±1333
±833
10000
8000
3333
2666
1666
±1666
±1333
±833
mA
15
15
15
15
15
15
15
15
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
%
90
91
92
92
91
90
90
91
90
91
92
92
91
90
90
91
88
89
90.5
91
90
89
89
91
µF
26600
20000
3900
2600
1300
± 2600
± 1600
±650
26600
20000
3900
2600
1300
± 2600
± 1600
±650
26600
20000
3900
2600
1300
± 2600
± 1600
±650
PART NUMBER STRUCTURE
FED40 Series Name
48
Input
Voltage
(VDC)
24: 9~36
48: 18~75
110: 43~160
S
Output
Quantity
S: Single
D: Dual
Page 1 of 4
05
Output
Voltage
(VDC)
3P3: 3.3
05: 5
12: 12
15: 15
24: 24
12: ±12
15: ±15
24: ±24
W Input
Range
4:1
www.pduke.com
N
HS
Remote Control
options
Heat-sink
: Positive logic
N: Negative logig
: No Heat-sink
HS Heat-sink
HC Heat-sink with Clamp
2013/03/15
FED40W
INPUT SPECIFICATIONS
Parameter
Conditions
24Vin(nom)
48Vin(nom)
110Vin(nom)
24Vin(nom)
48Vin(nom)
110Vin(nom)
24Vin(nom)
48Vin(nom)
110Vin(nom)
Power up
Remote ON/OFF
24Vin(nom)
48Vin(nom)
110Vin(nom)
Operating input voltage range
Start-up voltage
Shutdown voltage
Start up time
Constant resistive load
Input surge voltage
1 second, max.
Input filter
Remote ON/OFF
OUTPUT SPECIFICATIONS
Parameter
Voltage accuracy
Line regulation
Load regulation
Conditions
Cross regulation
Voltage adjustability
Asymmetrical load 25%/100% FL
Ripple and noise
Measured by 20MHz bandwidth
With a 0.1µF/50V X7R MLCC
Temperature coefficient
Transient response recovery time
Over voltage protection
Single output
Isolation resistance
Isolation capacitance
Switching frequency
Design meet safety standard
Page 2 of 4
-0.5
Typ.
75
100
150
% of Iout rated; Hiccup mode
Conditions
Min.
Input to Output
Input (Output) to Case
500VDC
℃
BELLCORE TR-NWT-000332 Case 1: 50% Stress, Ta= 40 .
MIL-HDBK-217F Ta=25 , Full load (G/B, controlled environment)
℃
www.pduke.com
VDC
VDC
VDC
ms
Max.
Unit
+1.0
+0.2
+0.5
+1.0
+5.0
+10
+20
%
%
100
125
200
+0.02
%
%
%
mVp-p
℃
%/
250
µs
3.9
6.2
15
VDC
20
30
150
%
Continuous, automatics recovery
3.3Vout
5Vout
12Vout
15Vout
24Vout
1 minute
Unit
50
VDC
100
170
Pi type
Open or 3 ~ 12VDC
Short or 0 ~ 1.2VDC
Short or 0 ~ 1.2VDC
Open or 3 ~ 12VDC
0.5
mA
3
mA
-1.0
-0.2
-0.5
-1.0
-5.0
-10
-10
3.3Vout, 5Vout
12Vout, 15Vout
24Vout
Case material
Base material
Potting material
Dimensions
Weight
MTBF
36
75
160
9
18
43
-0.02
GENERAL SPECIFICATIONS
Parameter
Isolation voltage
Single
Dual
Dual
3.3Vout, 5Vout, 12Vout
15Vout, 24Vout
25% load step change
Zener diode clamp
Over load protection
Short circuit protection
Max.
24
48
110
Min.
Low Line to High Line at Full Load
No Load to Full Load
Typ.
9
18
43
8
16
40
60
60
Positive logic
DC-DC ON
(Standard)
DC-DC OFF
Negative logic
DC-DC ON
(Option)
DC-DC OFF
Input current of CTRL pin
Remote off input current
Referenced to –INPUT pin
Min.
1600
1600
1
Typ.
Max.
Unit
VDC
GΩ
1500
pF
225
250
275
kHz
IEC60950-1, UL60950-1, EN60950-1
EN50155
Copper
FR4 PCB
Silicon (UL94-V0)
2.00 X 1.00 X 0.40 Inch
(50.8×25.4×10.2 mm)
32g (1.13oz)
2.661 x 106 hrs
9.865 x 104 hrs
2013/03/15
FED40W
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Maximum case temperature
Over temperature protection
Storage temperature range
Thermal impedance (1)
Conditions
Min.
Max.
+85
+105
+115
-55
Natural convection (20LFM)
Without Heat-sink
With Heat-sink
Thermal shock
Vibration
Relative humidity
EMC SPECIFICATIONS
Parameter
EMI (2)
Typ.
-40
Conditions
EN61000-4-2
Radiated immunity
Fast transient (3)
Surge (3)
Conducted immunity
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
℃
℃
℃
℃
℃/W
+125
10.8
10.3
EN61373, MIL-STD-810F
EN61373, MIL-STD-810F
5% to 95% RH
Level
EN55011,EN55022
ESD
Unit
Class A
Air ± 8kV
Contact ± 6kV
20 V/m
± 2kV
± 2kV
10 Vr.m.s
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1.
2.
3.
The heat-sink is optional and P/N: 7G-0020C-F.
The FED40 series standard module meets EN55022 Class A and Class B with external components. For more detail information, please contact
with P-DUKE.
An external filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The FED40-24W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS (SMDJ58A, 58V,
3000Watt peak pulse power) to connect in parallel. The FED40-48W recommended an aluminum electrolytic capacitor (Nippon chemi-con
KY series, 220µF/100V) and a TVS (SMDJ120A,120V, 3000Watt peak pulse power) to connect in parallel. The FED40-110W recommended
an aluminum electrolytic capacitor (Ruby-con BXF series, 68µF/200V 3pcs in parallel) and a TVS (SMDJ90A, 90V, 3000Watt peak pulse power
2pcs in series connection ) to connect in parallel
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
FED40-48S05W Derating Curve
FED40-48S05W Derating Curve with Heat-sink
FED40-48S05W Efficiency VS Input Voltage
Page 3 of 4
FED40-48S05W Efficiency VS Output Load
www.pduke.com
2013/03/15
FED40W
MECHANICAL DRAWING
PIN CONNECTION
PIN
SINGLE
DUAL
1
2
3
4
5
6
+ INPUT
- INPUT
CTRL
+ OUTPUT
- OUTPUT
TRIM
+ INPUT
- INPUT
CTRL
+ OUTPUT
COMMON
- OUTPUT
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the method
shown below.
1. All dimensions in inch (mm)
2. Tolerance :x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
3. Pin pitch tolerance ±0.01 (0.25)
4. Pin dimension tolerance ±0.004(0.1)
Page 4 of 4
www.pduke.com
2013/03/15