«Picture_Description» is depicted

Product Specification
Series: SCPE AccliMate™ IP68 Sealed Circular Ethernet Cable System
SCPE Series
SCRES Series
SCRE Series
Other items available for:
Cat 5e rating, Dust Caps (DCA-17-01 & DCA-17-02), Panel Plug (SCPPA-17-01)
See www.samtec.com for more information.
Revision: A
Date: August 1, 2014
Page 1
© Samtec, Inc.
Product Specification
Series: SCPE AccliMate™ IP68 Sealed Circular Ethernet Cable System
1.0 SCOPE
This specification covers performance, testing and quality requirements for Samtec SCPE AccliMate™ IP68 Sealed
Circular Ethernet Cable System.
2.0 DETAILED INFORMATION
2.1 Product prints, panel, catalog pages, test reports and other specific, detailed information can be found at
http://www.samtec.com/?SCPE, http://www.samtec.com/?SCRES and http://www.samtec.com/?SCRE.
3.0 TESTING
3.1
3.2
3.3
3.4
3.5
Current Rating: 1 A (8 Pins Powered)
Voltage Rating: 350 VAC
Ingress Protection: IP68
Operating Temperature Range: -40°C to +70°C
Electrical:
ITEM
TEST CONDITION
REQUIREMENT
STATUS
Withstanding Voltage
EIA-364-20 (No Flashover,
Sparkover, or Breakdown)
1050 VAC
Pass
Insulation Resistance
EIA-364-21 (5000 MΩ
minimum)
1,000 MΩ
Pass
Contact Resistance
(LLCR)
EIA-364-23
Δ 15 mΩ maximum
(Samtec defined)/ No damage
Pass
REQUIREMENT
STATUS
3.6 Mechanical:
ITEM
TEST CONDITION
Durability
EIA-364-09C
1000 cycles
Pass
Random Vibration
EIA-364-28 Condition V, Letter B
7.56 G 'RMS', 50 to 2000 Hz, 2
hours per axis, 3 axis total , PSD
0.04
Visual Inspection: No Damage
LLCR: Δ 15 mΩ maximum
Pass
Mechanical Shock
EIA-364-27 100 G, 6
milliseconds, sawtooth wave,
11.3 fps, 3 shocks/direction, 3
axis (18 total shocks)
Visual Inspection: No Damage
LLCR: Δ 15 mΩ maximum
Pass
Normal Force
EIA-364-04
30 grams minimum for Gold
interface
Pass
Revision: A
Date: August 1, 2014
Page 2
© Samtec, Inc.
Product Specification
Series: SCPE AccliMate™ IP68 Sealed Circular Ethernet Cable System
3.7 Environmental:
ITEM
TEST CONDITION
REQUIREMENT
STATUS
Thermal Shock
EIA-364-32
Thermal Cycles: 100 (30 minute dwell)
Hot Temp: +85°C
Cold Temp: -55°C
Hot/Cold Transition: Immediate
Visual Inspection: No Damage
LLCR: Δ 15 mΩ
DWV: 1050 VAC
IR: >1,000 MΩ
Pass
Thermal Aging
(Temp Life)
EIA-364-17
Test Condition 4 @ 105°C Condition B
for 250 hours
Visual Inspection: No Damage
LLCR: Δ 15 mΩ
DWV: 1050 VAC
IR: >1,000 MΩ
Pass
Cyclic Humidity
EIA-364-31
Test Temp: +25°C to +65°C
Relative Humidity: 90 to 95%
Test Duration: 240 hours
Visual Inspection: No Damage
LLCR: Δ 15 mΩ
DWV: 1050 VAC
IR: >1,000 MΩ
Pass
Gas Tight
EIA-364-36
Gas Exposure: Nitric Acid Vapor
Duration: 60 min.
Drying Temp.: 50°C +/- 3°C
Measurements: Within 1 hour of
Exposure
LLCR: Δ 15 mΩ
Pass
IP68
Dust/Water Testing per CEI/IEC 60529
Visual: No dust or water present
30 mins @ 10 Meters
Pass
4.0 MATED SYSTEM
Mated view information can be found at link below:
http://www.samtec.com/documents/webfiles/cpdf/SCPE%20Mated%20Document.pdf
Revision: A
Date: August 1, 2014
Page 3
© Samtec, Inc.
Product Specification
Series: SCPE AccliMate™ IP68 Sealed Circular Ethernet Cable System
5.0 KEYING FEATURES
Revision: A
Date: August 1, 2014
Page 4
© Samtec, Inc.
Product Specification
Series: SCPE AccliMate™ IP68 Sealed Circular Ethernet Cable System
6.0 PRINTS AND ASSEMBLY INSTRUCTIONS
6.1 Field termination kits
6.1.1 SCPFE Ethernet Field Termination Kit can be found at link below
http://www.samtec.com/documents/webfiles/cpdf/SCPFE-XX-X-XX-MKT.pdf
7.0 ADDITIONAL RESOURCES
7.1 For additional product information, contact our Customer Engineering Support Group at [email protected]
7.2 For RoHS, REACH or other environmental compliance information, contact our Product Environmental
Compliance Group at [email protected]
Revision: A
Date: August 1, 2014
Page 5
© Samtec, Inc.