● ● ● ● ● ● ● ● ● ● Features Regulated Converters Description 8kVDC & 10kVDC Reinforced Isolation Industry Standard DIP24 Package 6W Regulated Output Continuous Short Circuit Protection Wide Input 2:1 Medical Approved EN, CSA and CB Certificates 2 Pinout Options Control Pin Option Efficiency to 86% ECONOLINE DC/DC-Converter with 3 year Warranty 6 Watt DIP24 Reinforced Single & Dual Output The REC6 series uses a reinforced isolation transformer to offer exceptionally high isolation of 8kVDC (4kVAC/1 minute) or 10kVDC (5kVAC/1minute) making it suitable for HT monitoring circuits, mains power meters, IGBT isolated power supplies and other sophisticated industrial and medical applications. The isolation capacitance of only 20pF makes them also suitable for low leakage applications. The isolation transformer is recognized by CSA as reinforced isolated with a minimum internal clearance of 2.4mm and a minimum internal creepage clearance of 4.6mm. The REC6 is available in two industry-standard pinouts (= "/A" or "/C"). Remote on/off control is possible with the /CTRL option (A pinning only) and an optional undervoltage lockout function is also available (="/X1"). The converters can deliver 140% rated power for short periods of time to cope with applications with large capacitive loads or high start up currents. Selection Guide REC6-xx05SRW/R* Input Voltage (VDC) Output Voltage (VDC) 9 - 18, 18 - 36, 36 - 75 5 Output Efficiency Max Current Capacitive (mA) (%) Load (1) 1000 4.5 - 9 REC6-xx09SRW/R* 9 - 18, 18 - 36, 36 - 75 9 - 18, 18 - 36, 36 - 75 9 12 4.5 - 9 REC6-xx15SRW/R* 9 - 18, 18 - 36, 36 - 75 15 4.5 - 9 REC6-xx24SRW/R* 9 - 18, 18 - 36, 36 - 75 24 4.5 - 9 REC6-xx05DRW/R* 9 - 18, 18 - 36, 36 - 75 ±5 667 81, 82, 83 555 80 500 82, 83, 84 417 82 400 84, 85, 86 333 83 250 83, 84, 85 208 82 ±500 4.5 - 9 REC6-xx09DRW/R* 9 - 18, 18 - 36, 36 - 75 9 - 18, 18 - 36, 36 - 75 ±9 9 - 18, 18 - 36, 36 - 75 4.5 - 9 ±335 ±278 ±12 4.5 - 9 REC6-xx15DRW/R* RoHS ±250 ±208 ±15 ±200 ±167 6800µF REC6/R 4700µF 80, 81, 82 ±2200µF 81, 82, 83 ±2200µF 80 Derating-Graph (Ambient Temperature) 81, 82, 83 ±2200µF 82 82, 83, 84 ±2200µF 80 Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter. 2:1 Input (REC6-S_DRW/R8(R10) xx = 4.5-9Vin = 05 xx = 9-18Vin = 12 xx = 18-36Vin = 24 xx = 36-75Vin = 48 Ordering Examples: REC6-0512DRW/R8/A/CTRL= 5V Vin, ±12V Vout, 8kVDC isolation, pinout “A”,control pin REC6-4805SRW/R10/A = 48V Vin, 5V Vout, 10kVDC isolation, pinout “A” REC6-1212DRW/R8/C/X1 = 12V Vin, ±12V Vout, 8kVDC isolation, pinout “C”,UVL REC6-0505SRW/R10/A/CTRL/X1 = 5V Vin, 5V Vout, 10kVDC isolation, pinout “A”,control pin, UVL www.recom-power.com E-314885 C22.2-No. 60950 Certified C22.2-601.1 Certified UL-60601.1 Certified 6800µF R* = R8 or R10 for 8kVDC or 10kVDC isolation. * add suffix "/A" or "/C" for pinning options, see next page for details. * add suffix “/CTRL” for control pin option (A Pinning only) * add suffix "/X1" for Undervoltage Lockout 2011/65/EU 6/6 6800µF 77 4.5 - 9 REC6-xx12DRW/R* 6800µF 77 4.5 - 9 REC6-xx12SRW/R* 80, 81, 82 REV: 0/2015 Output Power (%) Part Number DIP24 120 100 80 Safe Operating Area 60 40 20 0 -40 0 25 50 75 85 Operating Temperature (°C) 105 125 Refer to Application Notes E-153 REC6-S_DRW /R* Series ECONOLINE DC/DC-Converter Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up) Input Voltage Range Output Voltage Accuracy Line Regulation Load Regulation Input Surge REC6/R Undervoltage Lockout (HL-LL) (for output load current change from 20% to 100%) (1 minute) 5V types 12V types 24V types 48V types (/X1 Versions) 5V types 12V types 24V types 48V types (0,1µF capacitor on output, 20MHz BW limited) (25% step change) (Full load and nominal input voltage) 2:1 ±2% max. ±0.3% max. ±0.6% max. 16V max. 25V max. 50V max. 100V max. 3.5V typ. (±20%) 7V typ. (±20%) 15V typ. (±10%) 32V typ. (±10%) 200mVp-p max. 1ms typ. 100kHz min. / 350kHz max. Pi Network MLCC capacitors only 20% Full Load 400mW max. 8000VDC 4000VAC / 60Hz 10000VDC 5000VAC / 60Hz 20pF typ. 10 GΩ min. Continuous, Auto Restart -40°C to +75°C (see Graph) 105°C max. -55°C to +125°C 95% RH Non-Conductive Plastic Silicone 20°C/W 14g 15 pcs per Tube 953 x103 hours 234 x103 hours Class A Class A 4.6 mm min. 2.4 mm min. 6.0 mm min. 6.0 mm min. 14.2 mm min. EN 60601-1 3rd Edition Output Ripple and Noise Transient Response Switching Frequency Input Filter Capacitors All types Minimum Load (Operation under no-load will not damage the converter, but it may not meet all specifications) No Load Power Consumption Isolation Voltage R8-Suffix (tested for 1 second) (rated for 1 minute**) Isolation Voltage R10-Suffix (tested for 1 second) (rated for 1 minute**) Isolation Capacitance Isolation Resistance Short Circuit Protection (Max operating temp. = 50°C during short circuit conditions) Operating Temperature Range (free air convection) Case Temperature Storage Temperature Range Relative Humidity Case Material Potting Material Thermal Impedance Natural convection Package Weight Packing Quantity MTBF (+25°C) using MIL-HDBK 217F Detailed Information see Application Notes chapter "MTBF" (+75°C) using MIL-HDBK 217F EMC Conducted Emissions EN55022 (with 470µF//0.1µF capacitors across input) Radiated Emissions EN55022 Reinforced Isolation Transformer Creepage /R8 and /R10 Types Transformer Clearance /R8 and /R10 Types PCB Creepage & Clearance /R8 and /R10 Types Optocoupler Creepage /R8 and /R10 Types External Creepage and Clearance Plastic Case Input <> Output pins Certifications EN Medical Safety Report: MDD1207051 + RM1207051 Medical Report + ISO14971 Risk Assessment IEC Medical Safety CB-Report: CA-10168-A1-UL IEC60601-1 3rd Edition CSA Medical Safety Report: 2202478 C22.2 601-1 2nd Ed. UL Medical Safety E314885-A4 UL 60601-1 3rd Edition General Safety Report: 2219431 C22.2 No. 60950-1-03 UL 60950-1 1st Ed. Recognised as Reinforced Isolation Supplement to Report: 2219431 } **Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. E-154 REV: 0/2015 www.recom-power.com REC6-S_DRW /R* Series ECONOLINE DC/DC-Converter Typical Characteristics Efficiency vs Vin Efficiency vs Load Efficiency VS Input Voltage Efficiency / Load 100 1205 4805 80 60 2405 40 Efficiency (%) Efficiency % REC6-xx05SRW/R* REC6-xx05DRW/R* 0505 20 0 0% 40% 20% 60% Total Output current (%) 80% 100% 80 4812 1212, 2412 20 0 0% 40% 20% 60% Total Output current (%) 80% 100% 4824 40 0524 1224, 2424 Efficiency (%) Efficiency % 60 20 www.recom-power.com 0 nom max max+20% 90 88 86 84 82 80 78 76 74 72 70 min max max+20% 4812 2412 1212 0512 nom Efficiency VS Input Voltage 80 REC6-xx24SRW/R* REC6-xx12DRW/R* 0505 Input Voltage (V) Efficiency / Load 100 1205 0% 40% 20% 60% Total Output current (%) 80% 100% 90 88 86 84 82 80 78 76 74 72 70 min 1224 4824 2424 0524 nom max max+20% Input Voltage (V) REV: 0/2015 E-155 REC6/R Efficiency % 40 Efficiency (%) REC6-xx12SRW/R* 2405 Efficiency VS Input Voltage 0512 60 4805 Input Voltage (V) Efficiency / Load 100 90 88 86 84 82 80 78 76 74 72 70 min REC6-S_DRW /R* Series ECONOLINE DC/DC-Converter Package Style and Pinning (mm) DIP 24 (continued) “A” Pinning 20.30 32.00 /R8 & /R10 Pin Connections 10.20 Pin # 4.1+0.25 /-0.5 15.24 0.51 4.60 Recommended Footprint Details 1.00 ø+0.15/0 (1) 2 Single Dual CTRL CTRL 1 (option) 11 2 –Vin –Vin 11 NC –Vout 14 +Vout +Vout 16 –Vout Com 22 +Vin +Vin 23 +Vin +Vin NC = No Connection Bottom View 23 22 16 2.54 14 2.54 CRTL Version only XX.X ± 0.5 mm XX.XX ± 0.25 mm Top View Vin+ CTRL Option 0V ON = Open or 0V< Vctrl <1.2V OFF = 2.2V< Vctrl <12V 2 REC6-xxxx/CTRL CTRL 1 1kW 1N4148 Off On REC6/R TTL Input 22,23 “C” Pinning 20.30 32.00 /R8 & /R10 Pin Connections 10.20 4.1+0.25 /-0.5 0.51 2.03 15.24 Recommended Footprint Details 1.00 ø+0.15/0 1 2 10 11 12 Single Dual 1 +Vin +Vin 2 +Vin +Vin 10 NC Com 11 NC Com 12 –Vout NC 13 +Vout –Vout 15 NC +Vout 23 –Vin –Vin 24 –Vin –Vin NC = No Connection Bottom View 24 23 Pin # 15 2.54 13 2.54 XX.X ± 0.5 mm XX.XX ± 0.25 mm Top View The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. E-156 REV: 0/2015 www.recom-power.com