RSO-S_D(Z) - Recom International Power Gmbh

Features
Regulated
Converters
Description
●
●
●
●
●
●
●
●
2:1 and 4:1 Wide Input Voltage Ranges
1kVDC, 2kVD or 3kVDC Isolation
UL94V-0 Package Material
Certified for Medical Applications
Continuous Short Circuit Protection
Low Noise
No External Capacitor needed
Efficiency to 83 %
ECONOLINE
DC/DC-Converter
with 3 year Warranty
High-power-density, an industrial temperature range of -40°C to +85°C and extra features like
On-Off-control are just some of the characteristics of this converter, ideal for highly sophisticated
industrial-designs. The RSO series is available with isolation of 2kV or 3kV by choosing option "/H2"
or "/H3" in which case it is also ideal for medical applications which additionally require EN-606011 certification. The standard version offers 2:1 input voltage range, while the “Z” version features 4:1
input voltage range, which includes an input voltage range covering both 5V and 12V supplies.
1 Watt
SIP8 Isolated
Single & Dual
Output
Selection Guide
Part Number
www.recom-power.com
REV: 0/2015
RoHS
2011/65/EU
6/6
EN-60950-1 Certified
EN-60601-1 Certified*
(*/H suffix)
RSO
Derating-Graph
(Ambient Temperature)
100
Output Power (%)
Input
Rated Output Output Current Efficiency
Max
Voltage Range
Voltage
typ.
Capacitive
SIP8
(VDC)
(VDC)
(mA)
(%)
Load(1)
RSO-xx3.3S*
4.5-9**, 9-18
3.3
300
68-72
3300µF
18-36, 36-72
70
RSO-xx05S*
4.5-9**, 9-18
5
200
73-75
1200µF
18-36, 36-72
75-78
RSO-xx09S*
4.5-9**, 9-18
9
111
74-78
680µF
18-36, 36-72
78-81
RSO-xx12S*
4.5-9**, 9-18
12
83
75-80
680µF
18-36, 36-72
80-83
RSO-xx15S*
4.5-9**, 9-18
15
67
75-80
680µF
18-36, 36-72
80-83
RSO-xx3.3D*
4.5-9**, 9-18
±3.3
±150
68-72
±1500µF
18-36, 36-72
70
RSO-xx05D*
4.5-9**, 9-18
±5
±100
73-75
±470µF
18-36, 36-72
75-76
RSO-xx09D*
4.5-9**, 9-18
±9
±56
74-78
±470µF
18-36, 36-72
78
RSO-xx12D*
4.5-9**, 9-18
±12
±42
75-79
±330µF
18-36, 36-72
79-80
RSO-xx15D*
4.5-9**, 9-18
±15
±34
75-79
±330µF
18-36, 36-72
79-80
RSO-xx3.3SZ*
9-36
3.3
300
68-70
3300µF
18-72
70
RSO-xx05SZ*
4.5-18**, 9-36
5
200
73-78
1200µF
18-72
75
RSO-xx09SZ*
4.5-18**, 9-36
9
111
75-81
680µF
18-72
78
RSO-xx12SZ*
4.5-18**, 9-36
12
83
77-83
680µF
18-72
80
RSO-xx15SZ*
4.5-18**, 9-36
15
67
78-83
680µF
18-72
80
RSO-xx3.3DZ*
9-36
±3.3
±150
70-74
±1500µF
18-72
70
RSO-xx05DZ*
4.5-18**, 9-36
±5
±100
73-77
±470µF
18-72
75
RSO-xx09DZ*
4.5-18**, 9-36
±9
±56
74-78
±470µF
18-72
78
RSO-xx12DZ*
4.5-18**, 9-36
±12
±42
75-80
±330µF
18-72
80
RSO-xx15DZ*
4.5-18**, 9-36
±15
±34
75-80
±330µF
18-72
80
No suffix is standard isolation (1kVDC) e.g, RSO-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RSO-0505S/H2, RSO-0505DZ/H3
** derate to 75% if Vin<5V, 12V 4:1 input also requires an external 10µF input capacitor.
4:1
80
60
40
30
20
0
2:1
Safe Operating Area
-40
0
50 7585 100
Operating Temperature °C
2:1 Input
(RS0-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
150
4:1 Input
(RSO-SZ/DZ)
xx = 4.5-18Vin = 12
xx = 9-36Vin = 24
xx = 18-72Vin = 48
Refer to Application Notes
E-123
RSO-S_D(Z)
Series
ECONOLINE
DC/DC-Converter
Specifications (Core Operating Area) measured at TA = 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified
Input Voltage Range
2:1 and 4:1
Output Voltage Accuracy
±2% typ.
Line Voltage Regulation
2:1
±0.2% max.
4:1
±0.5% max.
Load Voltage Regulation
2:1
±0.4% max.
(10% to 100% full load)
4:1
±0.5% typ.
Output Ripple and Noise (20MHz limited)
50mVp-p max.
2:1
200kHz min. / 500kHz max.
4:1
100kHz min. / 800kHz max.
100
See Selection Guide
80
60
Efficiency at Full Load
Quiescent Current
RSO-05xxS_D, SZ_DZ
40mA typ.
Nominal input Voltage
RSO-12xxS_D, SZ_DZ
32mA typ.
(Standard, /H2 and /H3)
RSO-24xxS_D, SZ_DZ
25mA typ.
RSO-48xxS_D, SZ_DZ
15mA typ.
CTRL Pin drive current /see Notes)
Standard
/H2 Version
1000VDC
(rated for 1 minute**)
500VAC / 60Hz
(tested for 1 second)
2000VDC
(rated for 1 minute**)
1000VAC / 60Hz
/H3 Version
(tested for 1 second)
3000VDC
Isolation Capacitance
Standard
2:1 Single
10pF min. / 40pF typ. / 60pF max.
Isolation Capacitance
/H2 and /H3
2:1 Single
5pF min. / 30pF typ. / 60pF max.
(rated for 1 minute**)
0
120pF min. / 170pF typ. / 250pF max.
Isolation Capacitance
/H2 and /H3
2:1 Dual
5pF min. / 30pF typ. / 60pF max.
Isolation Capacitance
Standard
4:1 Single/Dual
200pF max.
60
Isolation Capacitance
/H2 and /H3
4:1 Single/Dual
30pF max.
40
Operating Temperature Range (free air convection)
-40°C to +85°C (see Graph)
Storage Temperature Range
-55°C to +125°C
Relative Humidity
4.7g
Packing Quantity
22 pcs per Tube
(+85°C)
}
Detailed Information see
Application Notes chapter "MTBF"
using MIL-HDBK 217F
1685 x 103 hours
using MIL-HDBK 217F
254 x 103 hours
Certifications
EN General Safety Report: SPCLVD1212007
EN Medical Safety
60%
80%
100%
1205SZ
Efficiency %
80
20
0
0%
20%
40%
60%
80%
100%
Total Output current (%)
95% RH
Package Weight
MTBF (+25°C)
40%
20%
Efficiency / Load
2:1 Dual
Continuous
0%
100
Standard
Short Circuit Protection
2415
RSO-1205SZ
Isolation Capacitance
>1GΩ min.
2405
Total Output current (%)
1500VAC / 60Hz
Isolation Resistance
2409
20
10mA max.
(tested for 1 second)
2412
40
3mA typ, 6mA max.
Quiescent Input Current when Converter is OFF
Isolation Voltage
Efficiency / Load
Efficiency %
Operating Frequency
RS0
RSO-24xxS
10% (2)
Minimum Load
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please
refer to our Application Notes.
EN60950-1:2006 + A11:2009+A1:2010+A12:2011
Report: MDD1205098-3 + RM1205098-3
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
Notes
Note 1:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2:
The RSO series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
E-124
REV: 0/2015
www.recom-power.com
RSO-S_D(Z)
Series
ECONOLINE
DC/DC-Converter
Typical Application
Fuse
+Vin
Vin+
10µF input MLCC
capacitor
required for
RSO-12xxSZ_DZ
only.
Vout+
+Vout
RSO
-Vin
Vin-
Vout-
-Vout
Package Style and Pinning (mm)
8 PIN SIP Package
9.20
RECOM
R S O - x x x x S _ D 0.50±0.05
****
11.10
4.1
RECOM
RSO-xxxxS
****
RECOM
RSO-xxxxD
****
1 2 3
5 6 7 8
2.54
1.0ø+0.15/–0
Bottom View
3.20
2.0
2.54
5 6 7 8
Pin Connections
Recommended Footprint Details
21.80
0.32
Dual Output
1 2 3
0.50±0.05
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Single Output
Top View
Pin #
Single
1
–Vin
Dual
–Vin
2
+Vin
+Vin
3
CTRL
CTRL
5
NC
NC
6
+Vout
+Vout
7
–Vout
Com
8
NC*
–Vout
CTRL Examples:
NC = No Connection
Pin 8 (NC*) This pin is used internally and must have no external connection.
Pin 5 (NC)
Not connected internally.
NC* = NC, but no external Connection allowed.
RSO
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode.
When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is
ON. There is no allowed low state for this pin.
ON/OFF CONTROL
V+
VIN+
ON
LEAVE OPEN
+Vin
+Vout
3
CTRL
OFF
VIN-
5~12
1N4148
68
-Vin
CTRL
-Vout
Ω
10K
FET.
Remote ON/OFF
V-
ON: open or high impedance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor
I = 3V
O = 0.5V or GND
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
www.recom-power.com
REV: 0/2015
E-125