Features • Universal AC Input (85-264VAC) • Long 7 Year Warranty • Protections: SCP, OVP, OCP, OTP • 100% Full Load burn-in test • DC OK Indicator LED with Relay Contacts • cooling by free air convection, 5000m operation • UL, CSA & CE certified with CB Report Description This DIN-rail mounted power supply uses high reliability components to give a long, trouble-free life.The power supply can be end mounted to save space or side mounted for use in low-profile cabinets. Relay contacts simplify DC OK monitoring and the units can be deliver 60W start-up power. The REDIN series is fully certified for industrial use and carries a 7-year warranty. Selection Guide AC/DC Converter REDIN45 45 Watt DIN-Rail Power Supply YEA R 7 wa rranty Part Input Output Output Rated Efficiency Max. Number Voltage Range Voltage Trimming Voltage Current typ. Capacitive Load (VAC)(VDC) (VDC) (A) (%) (µF) REDIN45-1285-264 12 12-15 3.75 85 18800 REDIN45-2485-264 24 24-28 1.875 86 4700 * add suffix /NR for versions without relay Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) BASIC CHARACTERISTICS Parameter Condition Min. Input Voltage Range all operating conditions 85VAC max. Input Voltage max. 1 second Output Voltage Adjustment (Factory Setting) (1) Typ. Max. 264VAC 300VAC 375VDC 12Vout 24Vout 12-15VDC (12V±5%) 24-28VDC (24V±5%) Input Current full load, 115VAC full load, 230VAC 1.35A 0.75A Inrush Current cold start at 25°C, 115VAC cold start at 25°C, 230VAC 40A 60A standard (with Relay) /NR option (no Relay) <1000mW <500mW No Load Power Consumption Leakage Current 240VAC <1.0mA Start Up time cold start, 230VAC 500ms Rise time cold start, 230VAC 20ms Hold-up time full load, 115VAC full load, 230VAC 20ms 50ms Input Frequency 47Hz Operating Frequency 63Hz CB-Report UL-60950-1 Certified UL-508 Certified IEC-60950-1 Certified EN-60715 Compliant EN-50022 Compliant CSA C22.2 No. 60950-1-07 Certified 65kHz Efficiency see Selection Guide Output Ripple and Noise (2) Over Load Notes: Note1: Note2: 1000ms E224736 12Vout 24Vout all operating conditions 60mVp-p 75mVp-p 140% for 5 seconds max. For more details refer to Vadj. Derating Graph Ripple and Noise are measured at 20MHz bandwidth by using a 12” twisted pair-wire terminated with 0.1µF & 47µF parallel capacitor. Refer to Applications Notes continued on next page www.recom-international.com REV.: 1/2015 PA-1 REDIN45 AC/DC Converter Series Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) Efficiency vs. Load REDIN45-24 Efficiency (%) Efficiency (%) 90 80 70 60 50 40 30 20 10 0 REDIN45-12 85VAC 115VAC 230VAC 264VAC 0 1 3 2 3.75 90 80 70 60 50 40 30 20 10 0 85VAC 115VAC 230VAC 264VAC 0 0.5 1.5 1 Load (A) 1.875 Load (A) 100 90 80 Load (%) 70 60 100 80 80 12VDC Output Voltage (V) 40 Vadj. 15 (28) 60 50 40 30 20 Condition Line Regulation 10 Load Regulation 0 -20 Transient Response (3) 12VDC 70 REGULATION 30 Parameter 24VDC 90 45W max. 12 (24) 50 100 24VDC Load (%) Output Current (%) Vadj. Derating -10 20 Value 10 ±0.1 typ. / ±1% max. 0 10 30 50 70 -20 12Vout (step load change: 1.875A - 3.75A) Ambient Temperature (°C) 24Vout (step load change: 0.937A - 1.875A) -10 Dwell Time Slew Rate Notes: Derating: 3W / 1000m or 5°C / 1000m Note3: ±0.1 typ. / ±1% max. 50 70 ±5% typ. Ambient Temperature (°C) ±5% typ. 100Hz & 1kHz 50% duty 0.5A / µs 10 30 Derating: 1.5W / 1000m or 5°C / 1000m Transient Response + E-CAP loading 3300µF. Other specs with resistive load only. Ta= 35°C 5000 Ta= 55°C 5000 Parameter 4000 Altitude (m) Altitude (m) PROTECTION Condition Input Fuse Short Circuit Protection (SCP) 3000 Ta=Hiccup 50°C Over Voltage Protection (OVP) 12Vout 24Vout 2000 Over Current Protection (OCP) Over Temperature Protection (OTP) Isolation Voltage Isolation Resistance Power OK LED PA-2 20 Value T2.5A, slow blow type auto-recovery after Ta= fault 40°Ccondition 3000 18VDC max., shut-down latch-off o/p voltage, re-power on to recover 35VDC max., shut-down latch-off o/p voltage, re-power on to recover 2000 150% typ., auto-recovery after fault condition detect on inside ambient I/P to O/P 80 100 I/P to FG Load (%) O/P to FG 500VDC, 70% RH, I/P to O/P; I/P to FG; O/P to FG 40 4000 60 Relay Contacts LED/Relay 105°C±5%, shut-down latch-off o/p voltage, re-power on to recover 20 40 60 Load (%) 3.75kVAC / 1 minute 80 100 1.88kVAC / 1 minute 0.5kVAC / 1 minute 100MW min. 1A, 30VDC / 120VAC ON if Vout = 11-16V (12V) / 22-30V (24V) REV.: 1/2015 www.recom-international.com REDIN45 AC/DC Converter Series Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) ENVIRONMENTAL Parameter Condition Value Operating Temperature Range with derating -20°C to +70°C (see graph) Storage Temperature Range -30°C to +85°C Operating Humidity non-condensing 20% - 90%RH Storage Humidity 10% - 90% RH Vibration 10-500Hz 2G, 60min. Shock 3 times each axis 10G / 11ms, along X, Y and Z axis Altitude see derating graph 5000m MTBF (+25°C) MIL-HDBK-217F, 115VAC, 60Hz, 75% load 200 x 10³ hours Design Lifetime (+40°C) 87.6 x 10³ hours Derating Graph Vin ≤ 100VAC Vin ≤100VAC > 100VAC VinVin>100VAC 100 90 80 24VDC 12VDC Load (%) Vin ≤100VAC12VDC 70 100 60 -10 10 30 50 70 Temperature (°C) 20 24VDC 90 50 80 40 70 30 60 20 50 10 40 0 30-20 12VDC -10 10 30 50 70 50 70 Temperature (°C) 10 10 30 Temperature (°C) 5000 50 REDIN45-24 (45W) 50°C (45W) 4000 2000 3000 60 80 20 40 60 www.recom-international.com (45W) 4000 2000 3000 40 60 80 100 80 100 Load (%) 20 Load (%) (45W) 40°C 20 100 40°C 35°C 5000 3000 2000 80 35°C 4000 100 Load (%) 2000 30 5000 50°C 35°C 40 10 Temperature (°C) 4000 20 -10 35°C REDIN45-12 5000 3000 0 -20 70 Altitude (m) Altitude (m) -10 Typical Characteristics Altitude (m) Altitude (m) Vin >100VAC12VDC 70 100 60 20 10 0 -20 24VDC 90 Load (%) Load (%) Load (%) 80 90 50 80 40 70 30 60 20 50 10 40 0 30-20 100 24VDC 40 60 Load (%) REV.: 1/2015 PA-3 REDIN45 AC/DC Converter Series Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Standard UL General Safety E224736 UL-60950-1, 2nd Edition UL-508 UL-1310 C22.2 No. 60950-1-07, 2nd Edition IEC/EN General Safety E224736 IEC/EN-60950-1, 2nd Edition Chinese Safety Standard E224736 GB 4943.1-2011 CSA Certificate Type (Environmental) Report / Condition Standard / Criterion EMI Standard EN-55022, Class B Report: HA150146 EN-55024, Class B FCC15, Class B ESD Radiated Immunity Fast Transient Surge Conducted Immunity Power frequency magnetic field immunity test Noise Immunity EN-61000-4-2, Criteria A EN-61000-4-3, Criteria A EN-61000-4-4, Criteria A EN-61000-4-5, Criteria A EN-61000-4-6, Criteria A EN-61000-4-8, Criteria A EN-61000-4-11, Criteria A EN-61000-4-11, Criteria B EN-61000-4-11, Criteria B EN-61000-3-2 EN-61000-3-3 R±8kV Contact & Air Discharge 10V/m, 80-3000MHz, 80% AM at 1kHz Level 2 ±2kV / L-N, ±4kV / L, N-FG 10Vrms, 0.15-80MHz, 80% AM at 1kHz Harmonic Immunity Voltage Flicker 40% reduction, 200ms 70% reduction, 500ms 90% reduction, 5s not applicable input below 75W DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Type Value Case Material UL94V-0 plastic Dimensions (WxHxD) 45.1 x 92.0 x 101.2mm Weight 332g Packaging Dimensions (LxWxH) Cardboard Box Packaging Quantity 310 x 252 x 285mm Carton 30pcs Mechanical Dimensions 92.0 101.2 Front Side FG N L 45.1 continued on next page PA-4 REV.: 1/2015 DIN-RAIL mounting bracket www.recom-international.com Front Side REDIN45 FG N L AC/DC Converter Series 45.1 Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) Mechanical Dimensions DIN-RAIL mounting bracket (75mm) included 7.5±0.2 75±0.3 6.3±0.2 35±0.1 25.0 18±0.2 1±0.05 25.0 END MOUNTING SIDE MOUNTING Front Side FG N L End Latch Release Side Latch Release Tolerance: ±0.5mm Mounting Instruction Releasing Mounting 1 Front Side Front Side FG N L FG N L 2 2 „Click“ 1 continued on next page www.recom-international.com REV.: 1/2015 PA-5 REDIN45 AC/DC Converter Series Specifications (measured at TA= 25°C, 230VAC, full load and after warm up) Mounting Multiple Power Supplies FG N L FG N L 0mm FG N L 0mm no spacers between supplies required Functional Diagram L N T2.5A Input Filter Power Stage E +V Output Filter -V DC Relay OTP ShutDown Protection OCP Limit OVP ShutDown OK LED Output Voltage Regulation Vadj. The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. PA-6 REV.: 1/2015 www.recom-international.com