Filename: tfs 1220b.doc Version 1.5 VI TELEFILTER 15.03.2006 Filter specification Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 TFS 1220B 1/5 °C dBm 200 200 Characteristics Remark: The reference level for the relative attenuation arel of the TFS 1220B is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 1220,0 MHz without any tolerance. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value ae = amin Insertion loss (reference level) Nominal frequency fN Centre frequency ***** fC 2,1 dB tolerance / limit max. 1220,0 MHz 4,0 1220,0 MHz ± 2,0 MHz fN ± 4,0 fN - 10 MHz … fN + 9,0 Passband 1,3 1,1 Pass band ripple dB dB dB MHz MHz **** 1,5 3,0 dB dB min. min. 8,0 19,0 MHz MHz max. max. 1,5 3,0 min. min. min. min. min. min. min. min. min. 40,0 46,0 46,0 46,0 46,0 46,0 46,0 46,0 46,0 BW Bandwidth 1,5 dB 3,0 dB 25,0 28,0 MHz MHz arel Relative attenuation fN fN - 4,0 10,0 MHz … fN MHz … fN fN fN fN fN fN fN fN fN fN + 36,0 44,0 72,0 88,0 68,0 76,0 85,0 91,0 70,0 MHz MHz MHz MHz MHz MHz MHz MHz MHz + + 4,0 9,0 MHz MHz dB dB dB dB dB dB dB dB dB ns ns fN fN fN fN fN + 76,0 85,0 91,0 720,0 780,0 MHz MHz MHz MHz MHz 53,0 53,0 61,0 57,0 66,0 58,0 57,0 51,0 59,0 MHz … fN MHz … fN + + 4,0 9,0 MHz MHz 11 38 … … … … … dB dB **** dB dB dB dB dB dB dB dB dB Group delay ripple ** fN fN - 4,0 10,0 - - 40 °C ... + 85°C Reduced operating temperature range - + 20 °C ...+ 70 °C Storage temperature range - - 45 °C ... + 85°C Operating temperature range Temperature coefficient of frequency OTR - TCf ** - 43 ppm/K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) Aperture 500 KHz ***) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz) ****) Within reduced operating temperature range *****) At ambient temperature Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1220b.doc Version 1.5 VI TELEFILTER 15.03.2006 Filter specification TFS 1220B 2/5 0 -0.5 -20 -1 -30 -1.5 -40 -2 -50 -60 -3.5 -4 -90 -4.5 1100 1150 1200 1250 frequency in MHz 1300 1350 0.3 0.25 0.2 0.15 -3 -80 1050 0.35 -2.5 -70 -100 0.4 -5 1200 1400 0.1 group delay µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 0.05 0 -0.05 1205 1210 1215 1220 1225 frequency in MHz 1230 1235 -0.1 1240 Construction and pin connection (All dimensions in mm) C20B U11 1 2 3 4 5 6 7 8 Input Input Ground Ground Output Output Ground Ground Date code: U V W ... Year + week 2006 2007 2008 Date code 200 Test circuit 1 2 5 SAW 6 3, 4, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1220b.doc Version 1.5 VI TELEFILTER 15.03.2006 Filter specification TFS 1220B 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm "##$ %% &'() & * Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,5 ± 0,1 ( 1 ./0 ( +, '-(' ! W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1220b.doc Version 1.5 VI TELEFILTER 15.03.2006 Filter specification TFS 1220B 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1220b.doc VI TELEFILTER Version 1.5 Filter specification 15.03.2006 TFS 1220B 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification according to customer specification Dr. Sabah 05.11.2002 1.1 - Change of stamp from TFS1220 to TFS1220B Dr. Sabah 10.12.2002 1.2 - Filter specification, add of typical values Dr. Sabah 04.08.2003 1.3 - Add of second specification data sheet Dr. Sabah 18.08.2003 1.4 - Change construction, add Test circuit - Add filter characteristic Channaa 01.11.2005 1.5 - Change from a specification with floating tolerance scheme (fC based) to a specification with fixed tolerance scheme (fN based) - Correct stability characteristics Alawneh 15.03.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.