Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
360
360
|| -3,7 pF
|| -3,7 pF
Characteristics
Remark:
The reference level for the relative attenuation a rel of the TFS 211 is the minimum of the pass band attenuation. . This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
Nominal frequency
ae
4,5
-
fN
-
PB
Pass band
3 dB Bandwidth
Relative attenuation
fN
fN
fN
fN
±
±
±
±
200
400
600
800
dB
kHz
kHz
kHz
kHz
...
...
...
...
fN
fN
fN
fN
±
±
±
±
400
600
800
10
Group delay
arel
kHz
kHz
kHz
MHz
at fN
Group delay ripple within PB
Operating temperature range
OTR
Temperature coefficient of frequency
TCf **
6,5
±
dB
211,0
MHz
50
kHz
280
kHz
min.
200
kHz
10
30
35
40
dB
dB
dB
dB
min.
min.
min.
min.
5
25
30
35
dB
dB
dB
dB
µs
3,4
max.
5
µs
-
max.
0,5
µs
-
- 30 °C ... + 85 °C
+25
Frequency inversion temperature
max.
fN
-
Storage temperature range
tolerance / limit
-0,036
- 40 °C …+ 85 °C
°C
ppm/K²
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) f(Hz) = TCf(ppm/K) x (T-T0)² x fTo(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
VI TELEFILTER
Filter specification
Filter characteristic
Construction and pin connection
TFS 211
S33
50 Ohm Test circuit
C1
C2
1
6
3
L3
L1
L2
2,4,5,7,8,9,10
L4
1
6
3
C3
L5
L3
C4
2,4,5,7,8,9,10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
TFS 211
2/5
Filename: tfs 211.doc
Version 1.2
VI TELEFILTER
13.08.2004
Filter specification
TFS 211
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 7,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50 +0,1/-0
Ao
: 7,60 ± 0,10
Bo
: 9,60 ± 0,10
Ct
: 13,5
t
Date Code
Do
Ko
Typ
Po
PIN Marker
P2
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4
W2(max) : 22,4
N(min)
: 50
C
: 13,0
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211.doc
Version 1.2
VI TELEFILTER
13.08.2004
Filter specification
TFS 211
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
Name:
Temperature:
Time:
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / s ec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211.doc
VI TELEFILTER
Version 1.2
Filter specification
13.08.2004
TFS 211
5/5
History
Version
Reason of Changes
Name
Date
1.2.
Change Centre frequency to Nominal frequency
Change remark
Correct tapeand reel
Add history
Strehl
13.08.04
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.