Filename: tfs 211.doc Version 1.2 VI TELEFILTER 13.08.2004 Filter specification TFS 211 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 360 360 || -3,7 pF || -3,7 pF Characteristics Remark: The reference level for the relative attenuation a rel of the TFS 211 is the minimum of the pass band attenuation. . This value is defined as the insertion loss ae. The nominal frequency fN is fixed at MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) Nominal frequency ae 4,5 - fN - PB Pass band 3 dB Bandwidth Relative attenuation fN fN fN fN ± ± ± ± 200 400 600 800 dB kHz kHz kHz kHz ... ... ... ... fN fN fN fN ± ± ± ± 400 600 800 10 Group delay arel kHz kHz kHz MHz at fN Group delay ripple within PB Operating temperature range OTR Temperature coefficient of frequency TCf ** 6,5 ± dB 211,0 MHz 50 kHz 280 kHz min. 200 kHz 10 30 35 40 dB dB dB dB min. min. min. min. 5 25 30 35 dB dB dB dB µs 3,4 max. 5 µs - max. 0,5 µs - - 30 °C ... + 85 °C +25 Frequency inversion temperature max. fN - Storage temperature range tolerance / limit -0,036 - 40 °C + 85 °C °C ppm/K² - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) f(Hz) = TCf(ppm/K) x (T-T0)² x fTo(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. VI TELEFILTER Filter specification Filter characteristic Construction and pin connection TFS 211 S33 50 Ohm Test circuit C1 C2 1 6 3 L3 L1 L2 2,4,5,7,8,9,10 L4 1 6 3 C3 L5 L3 C4 2,4,5,7,8,9,10 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] TFS 211 2/5 Filename: tfs 211.doc Version 1.2 VI TELEFILTER 13.08.2004 Filter specification TFS 211 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 7,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 +0,1/-0 Ao : 7,60 ± 0,10 Bo : 9,60 ± 0,10 Ct : 13,5 t Date Code Do Ko Typ Po PIN Marker P2 D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 W2(max) : 22,4 N(min) : 50 C : 13,0 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 211.doc Version 1.2 VI TELEFILTER 13.08.2004 Filter specification TFS 211 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. Name: Temperature: Time: main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / s ec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 211.doc VI TELEFILTER Version 1.2 Filter specification 13.08.2004 TFS 211 5/5 History Version Reason of Changes Name Date 1.2. Change Centre frequency to Nominal frequency Change remark Correct tapeand reel Add history Strehl 13.08.04 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.