TFS140AE

Filename: tfs 140ae.doc
Version 1.2
VI TELEFILTER
08.04.2005
Filter specification
TFS 140AE
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50
50
Ω
Ω
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 140AE is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 6 dB
filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the
frequency response of the filter in the operating temperature range.
Data
typ. value
Insertion loss
(reference level)
ae
30,7
Centre frequency at operating
temperature
fC
-
Passband
fC ± fY * (1-a)
Pass band tilt within PB
Relative attenuation
dB
32
dB
140 ± 0,25 MHz
dB/MHz
max.
32
MHz
0,012 dB/MHz
dB
dB
dB
dB
min.
min.
min.
min.
40
40
50
50
1,2
deg
max.
±
0,1
dB
max.
±
0,25
dB
max.
0,004
arel
50
47
70
58
Deviation from theoretical phase response
∆ϕ
Deviation from theoretical frequency response
∆α
… fC ± fY * (1-a)
fC ± fY * (1-a) … fC ± fY * (1)
Nyquist frequency
Roll-off factor
Partitioning factor
fy
a
p
-
Group delay
at fc
1,1
µs
Group delay ripple within PB
9
ns
Input power level
-
Operating temperature range
Operable temperature range
Storage temperature range
Temperature coefficient of frequency
max.
PB
20
MHz … 115
MHz
165
MHz … 280
MHz
Reflected attenuation compared to main signal
Crosstalk attenuation compared to main signal
fC
tolerance / limit
OTR
TCf **
-72
dB
dB
dB
dB
4,5
deg
±
0,25
dB
±
0,5
dB
20
0,2
1,0
MHz
max.
25
ns
max.
15
dBm
+ 45 °C
- 45 °C ... + 85°C
- 45 °C ... + 85°C
ppm/K
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Theoretical frequency response :
⎧
P
⎪ H ( x ) = ( S ( x )) ;
⎪
⎪
⎧1
⎪
⎪
⎨
⎛
⎪ S ( x ) = ⎪ 1 ⋅ ⎜ 1 + cos
⎨
⎜
⎪
⎪2 ⎝
⎪
⎪
⎪
⎩ 0
⎩
where
,
x =
f − fC
fY
for
⎛ π ( x − 1 + a) ⎞⎞
⎟ ⎟ , for
⎜
⎟⎟
⎜
2a
⎠⎠
⎝
for
x ≤ (1 − a )
(1 − a ) ≤ x ≤ (1 + a ),
(1 + a ) ≤ x
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 140ae.doc
Version 1.2
VI TELEFILTER
08.04.2005
Filter specification
TFS 140AE
2/5
0
1.198
-1
1.186
-20
-2
1.174
-30
-3
1.162
-4
1.15
-5
1.138
-6
1.126
-70
-7
1.114
-80
-8
1.102
-90
-9
1.09
-40
-50
-60
-100
80.5
92.5
104.5 116.5 128.5 140.5 152.5 164.5 176.5 188.5 200.5
frequency in MHz
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
1.078
-10
119.5 123.7 127.9 132.1 136.3 140.5 144.7 148.9 153.1 157.3 161.5
frequency in MHz
Construction and pin connection
(All dimensions in mm)
TFS 140AE
●
T15
9 ± 0,2
24,64 ± 0,2
1
10 9 8 7 6
1,02
1,91 ± 0,2
2,31
3,53X4,83
1 2 3 4 5
2,6 Max.
Date code
1
2
3
4
5
6
7
8
9
10
Input
Ground
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Input RF Return
Date code:
T
U
V
...
Year + week
2005
2006
2007
Test circuit
1
2
3
4
5
10
9
8
7
6
50 Ω
50 Ω
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 140ae.doc
Version 1.2
VI TELEFILTER
08.04.2005
Filter specification
TFS 140AE
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
Pull Off Direc tion
Ko
Po
Da te Code
P1
P2
Ao
Bo
Ct
So
Do
E
t
W
Tape (all dimensions in mm)
W
: 44,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 20,20 ± 0,15
P2
: 2,00 ± 0,15
P1
: 16,00 ± 0,1
D1(min)
: 2,00
Ao
: 9,30 ± 0,1
Bo
: 24,90 ± 0,1
So
: 40,40 ± 0,1
Ct
: 38,0 ± 0,1
1000
min. 300 mm
min. 500 mm
min. 300 mm
Typ e
PIN Marker
D1
W2
Reel (all dimensions in mm)
A
: 330
W1
: 44,4 +2/-0
W2(max) : 50,4
N(min)
: 100
C
: 13,0 +0,5/-0,2
C
A
N
W1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 140ae.doc
Version 1.2
VI TELEFILTER
08.04.2005
Filter specification
TFS 140AE
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 140ae.doc
VI TELEFILTER
Version 1.2
Filter specification
08.04.2005
TFS 140AE
5/5
History :
Version
Reason of Changes
Name
Date
1.0
Generate development specification
Noack
25.05.2004
1.1
typical values and filter characteristic added
frequency range of passband-stopband transition modified
Pfeiffer
05.10.2004
1.2
- air reflow temperature profile modified
- set limits of centre frequency at operating temperature
Pfeiffer
08.04.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.