Filename: tfs 408.doc Version 1.5 VI TELEFILTER 11.04.2005 Filter specification TFS 408 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedances * for input: for output: Coupling coil: 23 °C 0 dBm 790 Ohm || - 1.45 pF 790 Ohm || - 1.45 pF 100 nH Characteristics Remark: Reference level for the relative attenuation arel of the TFS 408 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 408,0 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss in OTR Insertion loss in ROTR ae Nominal frequency fN Centre frequency fC Relative attenuation 3,7 3,7 dB dB tolerance / limit max. max. 408,035 5,5 5,0 408,0 MHz dB dB MHz - arel fN fN ± 100 kHz ... fN ... fN ± ± 100 150 kHz kHz fN fN ± ± + kHz kHz MHz MHz ... fN ... fN ... fN ... ± ± - fN 500 700 0,3 4,8 700 4,8 4,8 800 kHz MHz MHz MHz 0,4 2 dB dB max. max. 1,5 3 dB ** dB 30 44 53 55 dB dB dB dB min. min. min. min. 25 40 45 45 dB dB dB dB 1 µs max. 2 µs 10 Group delay ripple fN ± 150 kHz Input power level **** - max. Operating temperature range OTR - - 40°C ... + 85 °C Reduced operating temperature range ROTR - 0°C ... + 50 °C - - 55°C ... + 125 °C Storage temperature range Frequency inversion temperature T0 Temperature coefficient of frequency TCf *** *** 28 °C - -0,038 ppm/K² - dBm *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) 1 dB in reduced operating temperature range ***) ∆f(Hz) = TCf(ppm/K) x (T-T0)² x fTo(MHz). ****) also guaranteed 15 dBm for 1 minute over lifetime of filter Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 408.doc Version 1.5 VI TELEFILTER 11.04.2005 Filter specification TFS 408 2/5 Filter characteristic 0 0 -10 -1 -20 -2 -30 -3 -50 -60 -4 -5 4.91 -6 delay in µs -40 7.91 6.41 magnitude in dB magnitude in dB 9.41 3.41 -70 -7 -80 -8 -90 -9 1.91 0.41 -100 406 406.4 406.8 407.2 407.6 408 408.4 408.8 409.2 409.6 frequency in MHz -10 410 407.8 407.9 408 408.1 frequency in MHz 408.2 408.3 408.4 Construction and pin connection (All dimensions in mm) 5 7 S408 ● T15 3 7 5 0,1 1,1 120° +0,15 1,1 Input Input RF return External Coil Ground External Coil Output RF return Output Ground Date code: T U V ... Year + week 2005 2006 2007 1,8 Max. 1 Date cod e 0,64 3 5 - 0,10 1 1 2 3 4 5 6 7 8 2,54 50 Ω Test circuit L1 1 C1 L2 7 SAW C2 5 3 2, 4, 6, 8 L3 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 408.doc Version 1.5 VI TELEFILTER 11.04.2005 Filter specification TFS 408 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,30 ± 0,1 Bo : 5,30 ± 0,1 Ct : 9,5 ± 0,1 t P1 Date Code Po P2 W G Ct Bo F G E Do Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 408.doc Version 1.5 VI TELEFILTER 11.04.2005 Filter specification TFS 408 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 408.doc VI TELEFILTER Version 1.5 Filter specification 11.04.2005 TFS 408 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 27.09.2004 1.1 - Increase of operating temperature range Braun 12.10.2004 1.2 - Changed tolerance scheme according to customer request Martens 16.11.2004 1.3 - Changed specification according to customer requirement Martens 02.12.2004 1.4 - Replace single ended coupling coil by balanced coupling coil - Change pinning Dr. Wall 23.02.2005 1.5 - Added filter characteristic - Added typical values - Change to filter specification Martens 11.04.2005 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.