Filename: tfs 245c.doc Version 1.2 VI TELEFILTER 02.08.2007 Filter specification TFS 245C 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: External Coil: 23 0 °C dBm 530 Ω || -2.4 pF 530 Ω || -2.4 pF 270 nH Characteristics Remark: The reference level for the relative attenuation arel of the TFS 245C is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 245.76 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae 3.0 - Nominal frequency fN - PB - Passband Pass band ripple fN fN fN fN fN fN fN ± ± ± ± ± ± ± 330 400 600 800 1,6 3,0 20 kHz kHz kHz kHz MHz MHz MHz max. fN 5 - dB 245,76 MHz ± 89 kHz 0,5 dB max. 1,5 dB 1,5 dB max. 3 dB dB dB dB dB dB dB dB min. min. min. min. min. min. min. 18 25 40 45 45 46 45 dB dB dB dB dB dB dB µs µs µs max. max. max. arel Relative attenuation fN dB tolerance / limit … fN ± 120 kHz ... ... ... ... ... ... ... ± ± ± ± ± ± ± 400 600 800 1,6 3,0 20 100 kHz kHz MHz MHz MHz MHz MHz fN fN fN fN fN fN fN 22 33 41 47 52 54 55 Group delay ripple fN fN fN ± ± ± 50 70 100 kHz kHz kHz Operating temperature range 0,5 0,8 1,2 OTR Frequency inversion temperature TCf ** µs µs µs - 25 °C ... + 85 °C - Storage temperature range Temperature coefficient of frequency - 1,2 1,5 2,5 - 33 °C ... + 85 °C 25 °C - -0,036 ppm/K² - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)² x fTo(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 245c.doc Version 1.2 VI TELEFILTER 02.08.2007 Filter specification TFS 245C 2/5 0 0 -10 -1 6 -20 -2 5 -3 4 -4 3 -5 2 -30 -40 -50 -60 244.8 245 245.2 245.4 245.6 245.8 246 frequency in MHz -6 245.5 246.2 246.4 246.6 7 245.6 245.7 245.8 frequency in MHz 245.9 delay in µs magnitude in dB magnitude in dB Filter characteristic 1 246 Construction and pin connection (All dimensions in mm) S 245C ● V31 3 Date code 2 Max. 1 Input Ground External Coil External Coil Ground Ground Output Ground Ground Ground Ground Ground Date code: V W X ... Year + week 2007 2008 2009 1 5,2 Max. 2,54 ±0,2 7,2 Max. 2,54 ±0,2 1 1 2 3 4 5 6 7 8 9 10 11 12 0,80 50 Ω Test circuit 1 1 L1 7 L2 SAW C1 3 C2 4 2, 5, 6, 8, 9, 10, 11, 12 50 Ω Test circuit 2 C1 1 7 C2 SAW 3 L1 L2 4 2, 5, 6, 8, 9, 10, 11, 12 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 245c.doc Version 1.2 VI TELEFILTER 02.08.2007 Filter specification TFS 245C 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 t P1 Date Code Po P2 W G Ct Bo F G E Do Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 245c.doc Version 1.2 VI TELEFILTER 02.08.2007 Filter specification TFS 245C 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 245c.doc VI TELEFILTER Version 1.2 Filter specification 02.08.2007 TFS 245C 5/5 History Version Reason of Changes Name Date 1.0 Generate specification according to customer’s requirements Dr. Wall 04.08.2004 1.1 Change from development specification to filter specification Correct termination impedance Change typical value for insertion loss Add filter characteristic Dr. Wall 08.11.2004 1.2 Change storage temperature range and stability characteristics Strehl 02.08.2007 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.