TFS110W - Vectron International

Filename: TFS110W.doc
Version 1.4
Vectron International
26.03.2014
Filter specification
TFS 110W
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
25
0
°C
dBm
297 Ω || -23.3 pF
315 Ω || -24.6 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 110W is the minimum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 110.592 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole
operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
Nominal frequency
fN
Centre frequency
fC
Passband
dB
4.5
dB
110.592 MHz
MHz
fN
-
Relative attenuation
max.
110.592
PB
Pass band ripple
fN
3.5
tolerance / limit
max.
± 280
kHz
3
dB
arel
… fN
±
0.280 MHz
fN ±
1.150 MHz … fN
fN ±
1.728 MHz … fN
fN +
3.456 MHz … fN
fN 3.456 MHz … fN
5.184 MHz
fN fN 5.184 MHz … fN
Group delay ripple within PB
±
±
+
-
1.728
3.456
5.184
5.184
1
dB
max.
3
dB
18
35
45
49
53
50
100
dB
dB
dB
dB
dB
dB
ns
min.
min.
min.
min.
min.
min.
max.
10
30
40
45
50
40
700
dB
dB
dB
dB
dB
dB
ns
Input power level
max.
10
Permissible DC voltage
max.
3
-
MHz
MHz
MHz
MHz
15.000 MHz
p-p
Operating temperature range
-
- 20 °C ... + 70°C
Operable temperature range
-
- 40 °C ... + 85°C
Storage temperature range
-
- 40 °C ... + 85°C
Temperature coefficient of frequency
OTR
TCf **
-19
dBm
V
ppm/K
*) The terminating impedances depend on parasites and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS110W.doc
Version 1.4
Vectron International
26.03.2014
Filter specification
TFS 110W
2/5
0
5.58
-1
5.04
-12
-2
4.5
-18
-3
3.96
-24
-4
3.42
-5
2.88
-6
2.34
-42
-7
1.8
-48
-8
1.26
-54
-9
0.72
-30
-36
-60
100.6
102.6
104.6
106.6
108.6
110.6
112.6
frequency in MHz
114.6
116.6
118.6
-10
109.85
120.6
110
110.15
110.3
110.45
110.6
110.75
frequency in MHz
110.9
111.05
111.2
delay in µs
0
-6
magnitude in dB
magnitude in dB
Filter characteristic
0.18
111.35
Construction and pin connection
(All dimensions in mm)
S 110W
●
E41
Date code
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Input RF Return
Input
Date code:
E
F
G
...
Year + week
2014
2015
2016
50 Ohm Test circuit
10
L1
9
5
SAW
L2
L3
4
L4
1, 2, 3, 6, 7, 8
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS110W.doc
Version 1.4
Vectron International
26.03.2014
Filter specification
TFS 110W
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plane, 3 planes;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
5. ESD
-55 °C to 125°C / 15 min. each / 100 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
ANSI/ESD S20.20-1999, class 1A for HBM
This filter is RoHS compliant (2011/65/EU)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direc tion
Tape (all dimensions in mm)
W
: 16.00 ± 0.3
Po
: 4.00 ± 0.1
Do
: 1.50 +0.1/-0
E
: 1.75 ± 0.1
F
: 7.50 ± 0.1
G(min)
: 0.60
P2
: 2.00 ± 0.1
P1
: 8.00 ± 0.1
D1(min)
: 1.50
Ao
: 5.50 ± 0.1
Bo
: 7.50 ± 0.1
Ct
: 13.5 ± 0.1
P1
Da te Cod e
t
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16.4 +2/-0
W2(max) : 22.4
N(min)
: 50
C
: 13.0 +0.5/-0.2
C
A
N
W 1
The minimum bending radius is 45 mm.
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS110W.doc
Version 1.4
Vectron International
26.03.2014
Filter specification
TFS 110W
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS110W.doc
Vectron International
Version 1.4
Filter specification
26.03.2014
TFS 110W
5/5
History
Version
Reason of Changes
Name
Date
1.0
- generation of development specification
Strehl
10.06.2005
1.1
- change pass band and relative attenuation
Strehl
13.07.2005
1.2
- terminating impedance (preliminary value), typical values and filter characteristic added
- matching configuration changed
Pfeiffer
02.09.2005
1.3
- terminating impedance fixed
- typical values and filter characteristic changed
Pfeiffer
07.10.2005
1.4
- Input power level increased to 10dBm max, (was 0dBm).
- Added operable temperature range -40°C ...+85°C.
- Update headers and footers.
- Update stability characteristics, reliability
TCUK
26.03.2014
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.