Filename: tfs 140x.doc Version 1.3 VI TELEFILTER 03.03.2006 Filter specification TFS 140X 1/5 Measurement condition Ambient temperature: Input power level: Source and load impedance: Terminating impedances * Input: Output: 25 0±2 50 Ω °C dBm 99 Ω || - 28.3 pF 103 Ω || - 27.2 pF Characteristics Remark: The reference level for the relative attenuation arel of TFS140X is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme Data typ. value Insertion loss ae = amin Nominal frequency fN 9 140 dB limit max. 12 140,0 MHz Centre frequency fc (at ambient temperature) 139,60 ... 140,40 Pass band fN PB ± 7,1 dB MHz MHz MHz Amplitude ripple (peak to adjacent valley) within fN ± 7,2 MHz 0.2 Bandwidth 1 dB 3 dB 17,6 18,5 MHz MHz min. min. 17 17,75 MHz MHz 35 40 21,8 24,8 MHz MHz max. max. 24 48 MHz MHz dB dB max. max. 1 3 40 50 6 dB dB deg min. min. max. 35 40 10 dB dB deg p-p 44 ns max. 60 ns 777 ns max. 825 ns max. + 10 dB dB Relative attenuation fN ... fN ± fN ± 8,5 MHz ... fN ± max. dB arel fN ± 12 MHz ... fN ± MHz ... fN ± fN ± 24 Phase variation within PB 8,5 MHz 8,875 MHz 24 40 0,5 1,5 MHz MHz Group delay ripple within PB Absolute group delay within PB Input power level dBm - 40 °C ... + 85 °C Storage temperature range Temperature coefficient of frequency dB dB - 40 °C ... + 85 °C Operable temperature range *) 1 TCf -87 ppm/K The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 140x.doc Version 1.3 VI TELEFILTER 03.03.2006 Filter specification TFS 140X 2/5 0 1.182 -1 1.134 -14 -2 1.086 -21 -3 1.038 -28 -4 0.99 -5 0.942 -6 0.894 -49 -7 0.846 -56 -8 0.798 -63 -9 0.75 -35 -42 -70 100.5 108.5 116.5 124.5 132.5 140.5 148.5 frequency in MHz 156.5 164.5 172.5 -10 130.5 180.5 132.5 134.5 136.5 138.5 140.5 142.5 frequency in MHz 144.5 146.5 148.5 delay in µs 0 -7 magnitude in dB magnitude in dB Filter characteristic 0.702 150.5 Construction and pin connection (All dimensions in mm) TFS 140X ● U09 6,8Max. 13,6Max. 2,54 ±0,15 1,5 2,54 ±0,15 1 2 3 4 2,0Max. 1 12 5 11 6 Date code 10 9 8 7 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return Date code: U V W ... Year + week 2006 2007 2008 0,1 0,8 50 Ohm Test circuit L1 11 12 5 SAW C1 L2 6 C2 1, 2, 3, 4, 7, 8, 9, 10 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 140x.doc Version 1.3 VI TELEFILTER 03.03.2006 Filter specification TFS 140X 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 1700 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 24,00 +0,30/-0,10 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 11,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 Ao : 7,10 ± 0,10 Bo : 13,90 ± 0,10 Ct : 21,5 ± 0,1 t Po P2 W G Ct Bo F G E Do PIN Marker Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Air reflow temperature conditions Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 140x.doc Version 1.3 VI TELEFILTER 03.03.2006 Filter specification Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature TFS 140X 4/5 Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 140x.doc VI TELEFILTER Version 1.3 Filter specification 03.03.2006 TFS 140X 5/5 History Version Reason of Changes Name Date 1.0 generation of specification according to customer requirements E. Chilla 28.04.2003 1.1 group delay ripple changed absolute group delay added E. Chilla 21.04.2003 1.2 changed to filter specification terminating impedances added typical values added pass band added bandwidth for 1 dB, 3 dB, 35 dB changed relative attenuation changed E. Chilla 24.11.2003 1.3 filter characteristics added RoHS compliant added air reflow temperature conditions updated E. Chilla 03.03.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.