Filename: tfs 70at.doc Version 1.2 VI TELEFILTER 13.07.2006 Filter specification TFS 70AT 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 25 0 °C dBm 88 Ω || -30 pF 88 Ω || -32 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 70AT is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed at 70 MHz. The values for relative attenuation are guaranteed at ambient temperature. The frequency shift of the filter over temperature defined by the temperature coefficient of frequency Tcf is not included in the production tolerance scheme. Data typ. value Insertion loss : ( reference level ) Nominal frequency : Centre frequency : ae 14,9 fN - fc at ambient temperature (fCTA) Pass band : PB Relative attenuation : arel fN ... fN ± 10,15 fN ± 10,15 MHz ... fN ± 11 fN ± 14 fN ± 19 MHz MHz MHz ... fN ± 19 MHz MHz ... fN ± 40 MHz 35 Phase linearity (p-p) in 90%of PB 3,3 Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature Storage temperature range 0,4 2 0,88 Group delay ripple (p-p) in 90%of PB OTR dB - 94 16 dB 70 MHz MHz fN ± 38 45 Group delay (mean value in PB ) Operating temperature range 70,1 tolerance / limit 11 MHz dB dB max. max. 1 3 dB dB dB dB min. min. 35 38 dB dB µm max. ns max. 100 ns deg max. deg ppm/K 1,12 11 µs - ∆fc(Hz) = Tcf(ppm/K) x (T - TCTA) x fCTA (MHz) - 40 °C ... + 80 °C - 40 °C ... + 85 °C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70at.doc Version 1.2 VI TELEFILTER 13.07.2006 Filter specification TFS 70AT 2/5 0 1.525 -1 1.45 -12 -2 1.375 -18 -3 1.3 -24 -4 1.225 -5 1.15 -6 1.075 -42 -7 1 -48 -8 0.925 -54 -9 0.85 -30 -36 -60 20.2 30.2 40.2 50.2 60.2 70.2 80.2 frequency in MHz 90.2 100.2 110.2 120.2 -10 58.2 60.6 63 65.4 67.8 70.2 72.6 frequency in MHz 75 77.4 79.8 delay in µs 0 -6 magnitude in dB magnitude in dB Filter characteristic 0.775 82.2 Construction and pin connection (All dimensions in mm) TFS 70AT ● U28 6,8Max. 13,6Max. 2,54 ±0,15 1,5 2,54 ±0,15 1 2 3 4 2,0Max. 1 12 5 11 6 Date code 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return Date code: T U V ... Year + week 2005 2006 2007 10 9 8 7 0,1 0,8 50 Ohm Test circuit L1 C1 L2 11 5 12 6 L3 L4 C2 1,2,3,4,7,8,9,10 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70at.doc Version 1.2 VI TELEFILTER 13.07.2006 Filter specification TFS 70AT 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 1700 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 24,00 +0,30/-0,10 Po : 4,00 ± 0,1 Do : 1,50 +0,1/0 E : 1,75 ± 0,10 F : 11,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 Ao : 7,10 ± 0,10 Bo : 13,90 ± 0,10 Ct : 21,5 ± 0,1 t Po PIN Marker P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70at.doc Version 1.2 VI TELEFILTER 13.07.2006 Filter specification TFS 70AT 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70at.doc VI TELEFILTER Version 1.2 Filter specification 13.07.2006 TFS 70AT 5/5 History : Version Reason of Changes Name Date 1.0 generating specification according to customer requirements Chilla 10.12.2004 1.1 generating filter specification added terminating impedance changed relative attenuation added typical values added filter characteristic added test circuit changed chip-mount air reflow profile Chilla 28.06.2005 1.2 changed relative attenuation Chilla 13.07.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.