TFS70AT

Filename: tfs 70at.doc
Version 1.2
VI TELEFILTER
13.07.2006
Filter specification
TFS 70AT
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
25
0
°C
dBm
88 Ω || -30 pF
88 Ω || -32 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 70AT is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The nominal frequency fN is fixed at 70 MHz. The values for relative attenuation are guaranteed at
ambient temperature. The frequency shift of the filter over temperature defined by the temperature coefficient of frequency Tcf is not included in the
production tolerance scheme.
Data
typ. value
Insertion loss :
( reference level )
Nominal frequency :
Centre frequency :
ae
14,9
fN
-
fc at ambient temperature (fCTA)
Pass band :
PB
Relative attenuation :
arel
fN
... fN ± 10,15
fN ± 10,15 MHz ... fN ± 11
fN ± 14
fN ± 19
MHz
MHz
MHz ... fN ± 19 MHz
MHz ... fN ± 40 MHz
35
Phase linearity (p-p) in 90%of PB
3,3
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature
Storage temperature range
0,4
2
0,88
Group delay ripple (p-p) in 90%of PB
OTR
dB
- 94
16
dB
70
MHz
MHz
fN ±
38
45
Group delay (mean value in PB )
Operating temperature range
70,1
tolerance / limit
11
MHz
dB
dB
max.
max.
1
3
dB
dB
dB
dB
min.
min.
35
38
dB
dB
µm
max.
ns
max. 100
ns
deg
max.
deg
ppm/K
1,12
11
µs
-
∆fc(Hz) = Tcf(ppm/K) x (T - TCTA) x fCTA (MHz)
- 40 °C ... + 80 °C
- 40 °C ... + 85 °C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70at.doc
Version 1.2
VI TELEFILTER
13.07.2006
Filter specification
TFS 70AT
2/5
0
1.525
-1
1.45
-12
-2
1.375
-18
-3
1.3
-24
-4
1.225
-5
1.15
-6
1.075
-42
-7
1
-48
-8
0.925
-54
-9
0.85
-30
-36
-60
20.2
30.2
40.2
50.2
60.2
70.2
80.2
frequency in MHz
90.2
100.2
110.2
120.2
-10
58.2
60.6
63
65.4
67.8
70.2
72.6
frequency in MHz
75
77.4
79.8
delay in µs
0
-6
magnitude in dB
magnitude in dB
Filter characteristic
0.775
82.2
Construction and pin connection
(All dimensions in mm)
TFS 70AT
●
U28
6,8Max.
13,6Max.
2,54 ±0,15
1,5
2,54 ±0,15
1 2 3 4
2,0Max.
1
12
5
11
6
Date code
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Ground
Input
Input RF Return
Date code:
T
U
V
...
Year + week
2005
2006
2007
10 9 8 7
0,1
0,8
50 Ohm Test circuit
L1
C1
L2
11
5
12
6
L3
L4
C2
1,2,3,4,7,8,9,10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70at.doc
Version 1.2
VI TELEFILTER
13.07.2006
Filter specification
TFS 70AT
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 24,00 +0,30/-0,10
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/0
E
: 1,75 ± 0,10
F
: 11,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50
Ao
: 7,10 ± 0,10
Bo
: 13,90 ± 0,10
Ct
: 21,5 ± 0,1
t
Po
PIN Marker
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
: 60
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70at.doc
Version 1.2
VI TELEFILTER
13.07.2006
Filter specification
TFS 70AT
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70at.doc
VI TELEFILTER
Version 1.2
Filter specification
13.07.2006
TFS 70AT
5/5
History :
Version
Reason of Changes
Name
Date
1.0
generating specification according to customer requirements
Chilla
10.12.2004
1.1
generating filter specification
added terminating impedance
changed relative attenuation
added typical values
added filter characteristic
added test circuit
changed chip-mount air reflow profile
Chilla
28.06.2005
1.2
changed relative attenuation
Chilla
13.07.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.