Filename: tfs 125l.doc Version 1.3 VI TELEFILTER 14.03.2007 Filter specification TFS 125L 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 650 Ω || -14,5 pF 750 Ω || -12,8 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 125L is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 125 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae 5,7 Nominal frequency fN fN fN MHz MHz MHz MHz MHz MHz MHz MHz 7 dB 125 MHz ± 200 kHz max. 1 dB dB max. 1 dB dB dB dB dB dB dB dB dB min. min. min. min. min. min. min. min. 8 20 25 34 40 43 55 55 dB dB dB dB dB dB dB dB µs max. ns max. arel Relative attenuation 0,6 1,2 1,8 3,4 6,5 9,5 115 17 min. - Pass band ripple ± ± ± ± ± ± + dB PB Passband fN fN fN fN fN fN fN fN tolerance / limit … fN ± 200 kHz … … … … … … … … 1,2 1,8 3,4 6,5 9,5 17 17 325 MHz MHz MHz MHz MHz MHz MHz MHz fN fN fN fN fN fN fN fN ± ± ± ± ± ± + Group delay at fN 0,6 11 30 35 45 55 60 75 75 1,1 min. 60 Group delay ripple within PB VSWR 1,5 max. Input power level - max. Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf ** 0,7 120 10 - - 10 °C ... + 85 °C - 40 °C ... + 85°C -0,04 °C ppm/K µs µs ns 2,3 37 Frequency inversion temperature 1,7 dBm 2 - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = Tcf(ppm/K²) x (To - TA) ² x fCAT (MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 125l.doc Version 1.3 VI TELEFILTER 14.03.2007 Filter specification TFS 125L 2/5 0 1.59 -1 1.53 -20 -2 1.47 -30 -3 1.41 -4 1.35 -5 1.29 -6 1.23 -70 -7 1.17 -80 -8 1.11 -90 -9 1.05 -40 -50 -60 -100 100 105 110 115 120 125 130 frequency in MHz 135 140 145 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic -10 0.99 124.5 124.6 124.7 124.8 124.9 125 125.1 125.2 125.3 125.4 125.5 frequency in MHz 150 Construction and pin connection (All dimensions in mm) TFS 125L ● V11 10 1,0± 0,2 5 Date code 1,9± 0,2 1 1,8± 0,2 6,5 ± 0,2 13,3 ± 0,2 1,91± 0,2 7,62± 0,2 1 2 3 4 5 6 7 8 9 10 Input RF Return Ground Ground Ground Output Output RF Return Ground Ground Ground Input Date code: V W X ... Year + week 2007 2008 2009 6 50 Ω Test circuit L1 10 5 1 6 C1 L2 C2 2, 3, 4, 7, 8, 9 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 125l.doc Version 1.3 VI TELEFILTER 14.03.2007 Filter specification TFS 125L 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 1700 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 24,00 +0,30/-0,10 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 11,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 Ao : 7,10 ± 0,10 Bo : 13,90 ± 0,10 Ct : 21,5 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 125l.doc Version 1.3 VI TELEFILTER 14.03.2007 Filter specification TFS 125L 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 125l.doc VI TELEFILTER Version 1.3 Filter specification 14.03.2007 TFS 125L 5/5 History Version Reason of Changes Name Date 1.0 - generation of specification Steiner 12.8.04 1.1 - definition and limit for insertion loss changed - pass band bandwidth extended and limit for pass band ripple changed to 1,0 dB - limit for group delay ripple changed to 120ns - limits for relative relative attenuation modified - requirements for intermodulation removed Pfeiffer 31.08.2004 1.2 - terminating impedance and typical values added - typical filter characteristic added - air reflow temperature conditions modified Pfeiffer 15.10.2004 1.4 - change stability characteristics Strehl 14.03.2007 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.