TFS125L

Filename: tfs 125l.doc
Version 1.3
VI TELEFILTER
14.03.2007
Filter specification
TFS 125L
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
650 Ω || -14,5 pF
750 Ω || -12,8 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 125L is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 125 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
5,7
Nominal frequency
fN
fN
fN
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
7
dB
125
MHz
± 200
kHz
max.
1
dB
dB
max.
1
dB
dB
dB
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
min.
min.
8
20
25
34
40
43
55
55
dB
dB
dB
dB
dB
dB
dB
dB
µs
max.
ns
max.
arel
Relative attenuation
0,6
1,2
1,8
3,4
6,5
9,5
115
17
min.
-
Pass band ripple
±
±
±
±
±
±
+
dB
PB
Passband
fN
fN
fN
fN
fN
fN
fN
fN
tolerance / limit
… fN ±
200
kHz
…
…
…
…
…
…
…
…
1,2
1,8
3,4
6,5
9,5
17
17
325
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
fN
fN
fN
fN
fN
fN
fN
fN
±
±
±
±
±
±
+
Group delay
at fN
0,6
11
30
35
45
55
60
75
75
1,1
min.
60
Group delay ripple within PB
VSWR
1,5
max.
Input power level
-
max.
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
0,7
120
10
-
- 10 °C ... + 85 °C
- 40 °C ... + 85°C
-0,04
°C
ppm/K
µs
µs
ns
2,3
37
Frequency inversion temperature
1,7
dBm
2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K²) x (To - TA) ² x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 125l.doc
Version 1.3
VI TELEFILTER
14.03.2007
Filter specification
TFS 125L
2/5
0
1.59
-1
1.53
-20
-2
1.47
-30
-3
1.41
-4
1.35
-5
1.29
-6
1.23
-70
-7
1.17
-80
-8
1.11
-90
-9
1.05
-40
-50
-60
-100
100
105
110
115
120
125
130
frequency in MHz
135
140
145
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
-10
0.99
124.5 124.6 124.7 124.8 124.9 125 125.1 125.2 125.3 125.4 125.5
frequency in MHz
150
Construction and pin connection
(All dimensions in mm)
TFS 125L
●
V11
10
1,0± 0,2
5
Date code
1,9± 0,2
1
1,8± 0,2
6,5 ± 0,2
13,3 ± 0,2
1,91± 0,2
7,62± 0,2
1
2
3
4
5
6
7
8
9
10
Input RF Return
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Input
Date code:
V
W
X
...
Year + week
2007
2008
2009
6
50 Ω Test circuit
L1
10
5
1
6
C1
L2
C2
2, 3, 4, 7, 8, 9
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 125l.doc
Version 1.3
VI TELEFILTER
14.03.2007
Filter specification
TFS 125L
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 24,00 +0,30/-0,10
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 11,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50
Ao
: 7,10 ± 0,10
Bo
: 13,90 ± 0,10
Ct
: 21,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
: 60
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 125l.doc
Version 1.3
VI TELEFILTER
14.03.2007
Filter specification
TFS 125L
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max.
260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 125l.doc
VI TELEFILTER
Version 1.3
Filter specification
14.03.2007
TFS 125L
5/5
History
Version
Reason of Changes
Name
Date
1.0
- generation of specification
Steiner
12.8.04
1.1
- definition and limit for insertion loss changed
- pass band bandwidth extended and limit for pass band ripple changed to 1,0 dB
- limit for group delay ripple changed to 120ns
- limits for relative relative attenuation modified
- requirements for intermodulation removed
Pfeiffer
31.08.2004
1.2
- terminating impedance and typical values added
- typical filter characteristic added
- air reflow temperature conditions modified
Pfeiffer
15.10.2004
1.4
- change stability characteristics
Strehl
14.03.2007
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.