TFS520A

Filename: tfs 520a.doc
Version 1.2
VI TELEFILTER
04.08.2006
Filter specification
TFS 520A
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
750 Ω || -3,4 pF
700 Ω || -3,6 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 520A is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 520 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
ae =amin
Nominal frequency
Passband
Pass band ripple
fN
fN
fN
+
50,0
11,0
fN
-
PB
-
p-p
Relative attenuation
10,6
dB
tolerance / limit
max.
fN
±
12,0
dB
520,0
MHz
5,5
MHz
0,8
dB
max.
1,5
dB
0,8
dB
max.
1,5
dB
dB
dB
min.
min.
arel
... fN
±
5,5
MHz
MHz ... fN
MHz ... fN
+
11,0
50,0
MHz
MHz
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
42
44
40
40
-
-40 °C ... +80 °C
-
-45 °C ... +85 °C
-19
ppm/K
dB
dB
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 520a.doc
Version 1.2
VI TELEFILTER
04.08.2006
Filter specification
TFS 520A
2/5
0
2.52
-1
2.28
-20
-2
2.04
-30
-3
1.8
-4
1.56
-5
1.32
-6
1.08
-70
-7
0.84
-80
-8
0.6
-90
-9
0.36
-40
-50
-60
-100
370
400
430
460
490
520
550
frequency in MHz
580
610
640
-10
513
670
514.4
515.8
517.2
518.6
520
521.4
frequency in MHz
522.8
524.2
525.6
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
0.12
527
Construction and pin connection
(All dimensions in mm)
7
5
520A
● U31
3
5
7
Year + week
2006
2007
2008
0,1
1,1
120°
+0,15
1,1
Date code:
U
V
W
...
1,8 Max.
1
Ground
Ground
Output
Ground
Ground
Ground
Input
Ground
Date code
0,64
3
5 - 0,10
1
1
2
3
4
5
6
7
8
2,54
50 Ω Test circuit
7
L1
3
L3
SAW
L2
L4
1, 2, 4, 5, 6, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 520a.doc
Version 1.2
VI TELEFILTER
04.08.2006
Filter specification
TFS 520A
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,30 ± 0,1
Bo
: 5,30 ± 0,1
Ct
: 9,5 ± 0,1
P1
Date Code
Do
P2
W
G
Ct
Bo
F
G
E
t
Po
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 520a.doc
Version 1.2
VI TELEFILTER
04.08.2006
Filter specification
TFS 520A
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 520a.doc
VI TELEFILTER
Version 1.2
Filter specification
04.08.2006
TFS 520A
5/5
History
Version
Reason of Changes
1.0
Generate of development specification
Strehl
22.03.2006
1.1
Change operating temperature range and pin connection
Strehl
27.03.2006
Change from development specification to filter specification
Alawneh
04.08.2006
1.2
Name
Date
Change pass band ripple
Add typical values
Add filter characteristics
Add matching circuit
Add terminating impedance values
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.